HORIZONTAL SCALE 0
150
75
150
300
1"=150'
DRAWING INDEX
WATERVIEW APARTMENTS PHASE III
COVER
C 102
SITE PLAN
C 103
EXISTING CONDITIONS / DEMOLITION PLAN
SITE DEVELOPMENT PLANS
C 104
UTILITY PLAN
C 105
GRADING & EROSION CONTROL PLAN C 106 LANDSCAPING & LIGHTING PLAN C 201-203 DETAILS
MONROE COUNTY I NEW YORK SITE DATA
20243903.0002
PARCEL ADDRESS:
WILLOW POINT WAY WEBSTER, NY 14580
MUNICIPALITY:
TOWN OF WEBSTER
COUNTY:
MONROE
TOTAL PARCEL AREA:
13.152 ACRES OR 572,904 S.F.
AREA OF DISTURBANCE:
3.65 ACRES OR 158,994 S.F.
EXISTING ZONING:
MHR MEDIUM HIGH RESIDENTIAL
PROPOSED ZONING:
MHR MEDIUM HIGH RESIDENTIAL
EXISTING USE:
UNDEVELOPED
PROPOSED USE:
MULTI-FAMILY RESIDENTIAL - 56 TOWNHOMES
MC EWEN DR.
SITE
ZONING DATA
REQUIRED
PROPOSED
WILLOW
MHR MEDIUM HIGH RESIDENTIAL
N/F IRONDEQUOIT BAY SOUTH CTL PUR WAT T.A. NO. 093.060-01-3.1
N/F DEBRA L. KUHS T.A. NO. 093.060-01-024
' 157
N/F GEORGE E. KUGLER T.A. NO. 093.060-01-022
OHD
OHD
OHD
OHD
OHD
OHD
OHD OHD OHD
OHD
OHD
X
OHD
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
OHD
X
X
X
DHO
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
X
DHO
OHD
OHD
PROPOSED BIO-RETENTION AREA
GN
ITY UN MM R CO CENTE SF 00 ±1,5
OHD
MARITIME DRIVE
OHD
OHD
X
MA
RK G PA SF DO ,500 ±1
X
OHD OHD
D OH
OH
D
OHD OHD OHD
OHD
5 ACRES
13.152 ACRES
25%
9%
D
OH
INT PO
Y WA
Y WA
TOWN OF WEBSTER
LOCATION SKETCH N.T.S. STAMP:
SETBACK - FRONT
75'
18'*
SETBACK - SIDE
10'
15'
SETBACK - REAR
35'
N/A
SINGLE FAMILY DISTRICT BUFFER
100'
38'*
BUILDING LENGTH
165'
142'
SEPARATION
40'
40'
HEIGHT
3 STORIES MEASURED @ FRONT
2 STORIES
DENSITY
8 UNITS PER ACRE
4.3 UNITS PER ACRE
UNIT QTY
105
56
2 SPACES PER UNIT UNITS x 2= 112
56
124 SPACES/56 =2.20 SPACES PER UNIT
OHD
OHD
N/F WATERVIEW AT WILLOW POINT, LLC T.A. NO. 093.060-03-63.1
9' X 20'
STALL SIZE - PERPENDICULAR
9' X 20'
90/60/45 DEG
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
20'
* VARIANCE REQUIRED UN
MO
ENVIRONMENTAL DATA
ASH
VE
DRI
N TAI
ME
RITI
MA
IL
TRA
Jacob Lewis
AREA
STALLS QTY
E
OHD
AN
OHD
10/29/2024 11:08 AM
1805'
OHD OHD
D
CAPTAINS COVE LANE
D
OH
G RY TO DIN 2-S BUIL SED ME PO HO PROTOWN IT UN
27'
OHD
OH OH
LOW WIL
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 COVER.DWG
N/A
OHD
OHD
WINDRIDGE DRIVE
DEPTH
IA L
10
RY ING STO D 2- BUILD POSE ME PRO WNHO IT TO 10 UN
D
PROPOSED SAND FILTER
N/F LEGACY DEVELOPMENT CO. INC. T.A. NO. 093.060-03-64.21
330'
PARKING
OL
D OH
HIDDEN HARBOUR WAY
OHD OHD
X
X X
OHD
D
ALL KLEB T PIC OUR C
OA
OHD
PROPOSED BIO-RETENTION AREA
30'
YR
OHD
DHO
DHO
N/A
BA
OHD
OHD
DHO
OHD
OHD
DHO
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
PROPOSED BIO-RETENTION AREA
86'
OHD
PROPOSED 2-STORY 6 UNIT TOWNHOME BUILDING
51'
66'
N/F LEGACY DEVELOPMENT CO. INC. T.A. NO. 093.060-03-64.12
INT
BUILDING
165'
152'
McEWEN DRIVE
153'
N/F THOMAS MC EWEN T.A. NO. 093.060-01-002
WIDTH
COVERAGE
N/F SARAH H. JOHNSON T.A. NO. 093.060-01-026
PO
GE DRID WIN DR.
LOT
N/F JOHN P. HENDLER SR. T.A. NO. 093.060-01-025
D OA YR
093.06-3-64.11
BA
TAX ACCOUNT NUMBER:
MARITIME DR.
TOWN OF WEBSTER l
C 101
NO
YES
STATE REGULATED WETLANDS (NYSDEC ERM):
Passero Associates 242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
(585) 325-1000 FAX: (585) 325-1691
PROJECT MANAGER PROJECT ENGINEER DESIGNER
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
X
FEDERALLY REGULATED WETLANDS (USFWS NWI):
X
NO. DATE BY
DESCRIPTION
1
IRONDEQUOIT BAY
FLOOD PLAIN (FEMA NFHL): FIRM PANEL: 36055C0209G DATED: 8/28/2008
ZONE X AREA OF MINIMAL FLOOD HAZARD
2 3 4
ENDANGERED SPECIES (NYSDEC ERM):
X
5 6 7 8
UTLITIES DATA PUBLIC WATER PROVIDED BY:
MONROE COUNTY WATER AUTHORITY
ELECTRIC SERVICE PROVIDED BY:
RG&E
SANITARY SEWER PROVIDED BY: STORM SEWER & DRAINAGE WILL BE: (MAINTAINED BY THE OWNER)
UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
COVER SHEET
RG&E TOWN OF WEBSTER SANITARY SEWER DISTRCIT PRIVATE AND MAINTAINED AS PART OF THE TOWN OF WEBSTER CONSOLIDATED DRAINAGE DISTRICT
ALL IMPROVEMENTS SHALL BE MADE IN ACCORDANCE WITH THE CURRENT DEVELOPMENT STANDARDS AND SPECIFICATIONS OF THE MUNICIPALITY
WATERVIEW PHASE III WEBSTER, NY
TOWN/CITY: WEBSTER COUNTY: MONROE
NY
PROJECT NO.:
20243903.0002 DRAWING NO.:
C 101 DATE:
OCTOBER 2024
HORIZONTAL SCALE 30
0
15
30
60
1"=30'
5/8" REBAR FND
110'
N/F 436 MCEWEN DR. PUMP STATION 1" PIPE FOUND
5/8" REBAR FOUND
2" PE GAS MAIN
MC EWEN DRIVE
EXISTING 10' WIDE INGRESS AND EGRESS EASEMENT CENTERED ON PROPERTY LINE PER LIBER 8923 OF DEEDS, PAGE 565 & LIBER 2328 OF DEEDS, PAGE 519
CURVE 15 MPH
54.7'
3'
OHD
X
X
OHD OHD
STAMP:
15A PROPOSED RETAINING WALL. BROADSTONE 6" MEDLEY BY KEYSTONE (TYP)
OHD
X
N.T.S.
OHD
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
9'
7.9'
LOCATION SKETCH
18.7'
OHD
X
PROPERTY BOUNDARY EXISTING CENTER LINE ROAD
OHD
SETBACK
OHD
14
OHD
14B
PROPOSED PAVEMENT STRIPING
PROPOSED CURB PROPOSED SIGN
28.7' TRANS.
EXISTING SIGN
Passero Associates 242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
(585) 325-1000 FAX: (585) 325-1691
PROJECT MANAGER PROJECT ENGINEER DESIGNER
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
NO. DATE BY
DESCRIPTION
1 2 3 4 5 6
'
7 LP
33.3
8
OH
D
OH
'R
EXISTING LIGHT POLE (TYP)
'
E SID K 10' C A B SET
O
PROPOSED BUILDING MOUNTED LIGHT
15.4
D
OH
PROPOSED LIGHT POLE
TRANS CTV
TEL
OHD OHD
PROPOSED PARKING COUNT PROPOSED ACCESS RAMP WITH DETECTABLE WARNING
CTV
OHD
90
UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
N/F WATERVIEW AT WILLOW POINT, LLC T.A. NO. 093.060-03-63.1
D
16'
'R
NO TRESPASSING DEAD END
SITE PLAN
APPROVALS 0' G2 STIN TORM MENT I X E E S ASE WID ER E SEW
57
5/8" REBAR FOUND
PROPOSED BUILDING
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
PROPOSED CONCRETE
14A OHD
OHD
D
CLIENT:
PROPOSED ASPHALT PAVEMENT
14C
MARITIME DRIVE
OHD
'
RY STO ILDING 2 D U OSE OME B P O PR WNH O T T NI 10 U
PROPOSED 6" REVEAL CONCRETE CURB
40'
EXISTING BUILDING 47'
3'
LAWN AREA
75' FRONT SETBACK
5'
LP
42.4
D
20'R
5'R
OH
Jacob Lewis
PROPOSED POST TOP LIGHT (TYP)
Y WA
EXISTING EASEMENT LINE
LAWN AREA
SNOW STORAGE
INT
TOWN OF WEBSTER
PROPOSED BIO-RETENTION AREA
HD
0'R 11
N/F LEGACY DEVELOPMENT CO. INC. T.A. NO. 093.060-03-64.21
OHD
OHD
10/29/2024 11:09 AM
LAWN AREA
OH
TING EXIS IDE 20' W RM STO R E SEW T MEN E S EA
15B
X
OHD
D
OH
PROPOSED 5' WIDE MOWED GRASS PATH
36.2'
PO
GE DRID WIN DR.
LEGEND
LT
G RY TO DIN 2-S BUIL SED ME PO HO PROTOWN IT UN
D
OH
'
9.5
X
10
D OH
7'
62.
9.3'
WILLOW
DOOR (TYP)
30'
48'
10 SPHA A SED NT PO EME PRO PAV
D OH
10' SID
45'
X
10'
ACK E SETB
ITY UN MM ER CO ENT SF C 500 ±1, 66'
40'
24' PROPOSED ADA COMPLIANT PARKING SPACES & SIGNAGE PER DETAIL
10'
20'R
20'
210'R
190'R
PROPOSED 4' WIDE STONE STRONG RETAINING WALL
TRES NO
PAS
SING
W
W ILLO
P
T OIN
PLANNING BOARD CHAIRMAN
AY
W
COMMISSIONER OF PUBLIC WORKS
LP
MA
WINDBRIDGE DRIVE LP
TOWN/CITY: WEBSTER COUNTY: MONROE
ME
FIRE MARSHAL
21C
NY
PROJECT NO.:
18B
20243903.0002 HIGHWAY SUPERINTENDENT
VE
DRI
21D
WATERVIEW PHASE III WEBSTER, NY
TOWN ASSESSOR
18A
RITI
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 SITE.DWG
4' OHD
OHD
15'
6.8'
9'
20'R
LAWN AREA
PROPOSED SAND FILTER
48.6'
59.9'
R
X
5'
5'
OHD
K AR G P SF DO ,500 ±1
X
20'
X 20'
OHD
X
X
OHD
3' TRANSITION CURB TO GRADE
17.7'
4
5'R 44'
X
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
X
ALL LEB T K PIC OUR C 4'
SNOW STORAGE
PROPOSED ASPHALT DRIVEWAY (TYP)
PROPOSED BIO-RETENTION AREA
X
DHO
X
DHO
41.8'
38.5'
67
OHD
105.6'
OHD
OHD
64'
MC EWEN DR.
SITE
34'
PROPOSED 6' WIDE CONCRETE SIDEWALK
PATIO (TYP)
OHD
'R
15.4'
OHD
OHD PROPOSED BIO-RETENTION AREA
D OA YR
PROPOSED STONE STRONG RETAINING WALL WITH 4' TALL DECORATIVE BLACK METAL FENCE (TYP)
15C
LP
BA
47.2'
DHO
DHO
DOOR (TYP)
141.9'
20'
OHD
54.7'
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
56.3'
OHD
28.4'
75' FRONT SETBACK
OHD
OHD
20'
25'
DHO
PROPOSED ASPHALT DRIVEWAY (TYP)
40'
OHD
OHD
3'
5'
12.2'
10.9'
75' FRONT SETBACK
PROPOSED 2-STORY 6 UNIT TOWNHOME BUILDING
OHD
LAWN AREA
EXISTING 30' WIDE SANITARY SEWER EASEMENT
95.4'
19.8'
LAWN AREA
6.8'
OHD
N/F LEGACY DEVELOPMENT CO. INC. T.A. NO. 093.060-03-64.12
16.1'
12.2'
16.1'
OHD
LOT AR-2
18'
25.6'
25.6'
18'
PROPOSED 2.5' WIDE CONCRETE GUTTER
AREA = 572,904 SQ FT OR 13.152 ACRES +/-
DHO
12'
12'
MARITIME DR.
17'R
LAWN AREA
OHD
87' R
EXISTING 50' WIDE EASEMENT TO MCWA
OHD
N/F THOMAS MC EWEN T.A. NO. 093.060-01-002
18C
DRAWING NO.:
C 102 DATE:
OCTOBER 2024
HORIZONTAL SCALE 30
DRAINAGE INLET MH TG=393.92' N.INV=387.52' E.INV=387.67' S.INV=388.32'
18"
DRAINAGE INLET MH TG=395.53' NE.INV=390.88' E.INV=388.43' W.INV=388.43'
CM P
IL 8" T
31 LF 12" CPP @ 3.42%
E
5/8" REBAR FND
CB TG=359.59' SW.INV=391.94'
210 LF 15" CMP @ ?%
1" PIPE FOUND
30
60
41 LF 8" PVC @ 2.20%
42 LF 12" CMP @ 6.26%
46 LF 15" CMP @ 10.15%
5/8" REBAR FOUND
Dig Safely. New York
15" CMP
1-800-962-7962 i-Notice = www.DigSafelyNewYork.com
HH WATER METER
35 LF 8" PVC @ 1.11%
MC EWEN DRIVE
SMH RIM=396.03' NE.INV=387.58' W.INV=387.58'
49 LF 36" RCP @ 0.59%
TG=394.85' SW.INV =390.95'
191 LF 15" CMP @ 4.83%
If you excavate anywhere in New York State, except NYC or Long Island, call
24 LF 15" CMP @ 2.33% 2" PE GAS MAIN
8" VC P
55 LF 15" CMP @ 1.38%
DRAINAGE INLET MH TG=422.99' E.INV=413.99' W.INV=413.99'
9 LF 15" CMP @ 1.11%
DMH RIM=410.05' S.INV=405.15' E.INV=404.75' W.INV=404.55'
HYD WV WV
STEEL GUARDRAIL
N/F THOMAS MC EWEN T.A. NO. 093.060-01-002
15
1"=30' SMH RIM=395.49' N.INV=377.59' S.INV=377.59' E.INV=387.19' E.INV=379.49' W.INV=379.49' N/F 436 MCEWEN DR. PUMP STATION
SMH RIM=394.74' N.INV=380.39' E.INV=380.39'
EXISTING 10' WIDE INGRESS AND EGRESS EASEMENT CENTERED ON PROPERTY LINE PER LIBER 8923 OF DEEDS, PAGE 565 & LIBER 2328 OF DEEDS, PAGE 519
0
CURVE 15 MPH
CB TG=409.96' N.INV=405.86'
FORCE MAIN
SMH RIM=397.78' N.INV=377.88' S.INV=377.88'
DRAINAGE INLET MH TG=410.20' NW.INV=405.25' S.INV=405.30'
DRAINAGE INLET MH TG=424.36' E.INV=418.66' W.INV=418.66'
FORCE MAIN
EXISTING 50' WIDE EASEMENT TO MCWA
EXISTING TREE LINE
LEGEND PROPERTY BOUNDARY EXISTING CENTER LINE ROAD
6" DI STAND PIPE
LOT AR-2
CB TG=423.24' S.INV=418.79'
EXISTING BUILDING EXISTING EASEMENT LINE EXISTING MAJOR CONTOUR
117 LF 36" RCP @ 0.04%
AREA = 572,904 SQ FT OR 13.152 ACRES +/-
EXISTING MINOR CONTOUR EXISTING STORM SEWER CB, MH & INLET MH
168 LF 12" CPP @ 3.31%
HYD
HYD
WV
WV
BA
EXISTING SIGN
EXISTING ELECTRIC LINE
SMH RIM=398.78' N.INV=377.93' S.INV=377.93'
LP
15B
SITE
EXISTING LIGHT POLE
TRANS
EXISTING TRANSFORMER
CTV
EXISTING CTV
EM
EXISTING ELECTRIC METER
HHE
EXISTING ELECTRIC HANDHOLE
WILLOW
PO
INT
Y WA
GE DRID WIN DR.
TOWN OF WEBSTER
EXISTING GAS VALVE REMOVE EXISTING TREES & BRUSH
MARITIME DR.
MC EWEN DR.
EXISTING SANITARY SEWER AND MANHOLE
LP HHE
D OA YR
EXISTING 30' WIDE SANITARY SEWER EASEMENT
N/F LEGACY DEVELOPMENT CO. INC. T.A. NO. 093.060-03-64.12
EXISTING WATER SERVICE HYDRANT & VALVE
LOCATION SKETCH
EXISTING GAS MAIN
N.T.S.
EXISTING TREE/BRUSH LINE STAMP:
15A
PROPOSED TREE LINE
TREE LINE
TREES / BRUSH TO BE REMOVED
WV HYD
196 LF 36" RCP @ 0.14%
CB TG=417.43' E.INV=413.68'
DMH RIM=421.38' N.INV=413.23' S.INV=412.83' W.INV=412.43'
LP HHE
TH G PA
10/29/2024 11:09 AM
TIN EXIS
183 LF 12" CPP @ UNDETERMINED%
Passero Associates 14B
P@ %
2 5.4
HHE
CTV HHE
CB TG=413.83' E.INV=411.03' S.INV=410.98'
N/F LEGACY DEVELOPMENT CO. INC. T.A. NO. 093.060-03-64.21
REMOVE AND DISPOSE OF EXISTING CB
EX. CB TG=383.61' S.W.INV=381.71'
ND NE ECPP ' 24" 381.13 CPP INV= ND 12" E 5 E 5 N 381. CPP INV= LF 24" 66 67% @ 1.
23 LF 8" CMP @ 8.68%
5 6
REMOVE AND DISPOSE OF EXISTING DMH
5/8" REBAR FOUND
NO TRESPASSING DEAD END
388.33'
WINDBRIDGE DRIVE HHE
HHE
WV HYD
58 LF 2 4" CPP
NO
O
(REL
DMH390.78' 3' TG= =382.2 ' V N.IN =384.78 8' V .6 E.IN V=382 IN SW.
E) CAT
W
W ILLO
T OIN
Y WA
P
HHE @ PP " C ED% 4 2 IN LF 85 ETERM D UN
CB 403.23' 88' TG= V=399. W.IN
21D
21C
EXISTING CONDITIONS & DEMOLITION PLAN WATERVIEW PHASE III WEBSTER, NY
TOWN/CITY: WEBSTER COUNTY: MONROE
NY
PROJECT NO.:
18B
20243903.0002 DRAWING NO.:
VE
' SMH 391.28 43' = RIM 378.
DMH TG=412.28' N.INV=DID NOT MEASURE N.INV=408.48' E.INV=407.98' W.INV=407.98'
UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
18A
DRI
' DMH 395.30 65' = RIM V=387. ' NE.IN =387.15 ' 5 V E.IN =387.1 V W.IN
4% @ 9.0
15
400.64'
LP
@ 4.95 %
' V= N.IN =378.43 ' V 3 N 6 I . . 0 S =38 .58' V N I E. 82 8' V=3 E.IN =380.7 V N I . W
P 8" CP 8 LF 1
ME
MB
15" CMP
RITI
LP
U
N/F WATERVIEW AT WILLOW POINT, LLC T.A. NO. 093.060-03-63.1
HHE
P@ CM D% F 8" 49 L ERMINEASSING T NDE TRESP
62 LF 12" CPP @ 4.69%
413.79'
PM GAS N-S
P
MA
CB TG=386.96' N.INV=384.46'
46 LF 8" CMP @ 5.43%
402.97'
0' G2 TIN ORM ENT S I EX E ST SEM A WID ER E SEW
387.29'
DB-3.1 EX. DMH TG=383.62' N.INV=379.42' NE.INV=379.72'
7 8
CB TG=413.00' E.INV=411.10' PM GAS N-S
CM F 8" 37 L 97% @ 9.
CB 83' 6 39 . TG= 92.33' V=3 W.IN
DESCRIPTION
4
TRANS CTV
PM GAS E-W
202 LF 36" RCP @ 0.11%
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
3
LP
DMH401.19' 9' TG= =396.1 ' V E.IN =393.69 ' V E.IN =393.69 V W.IN
PROJECT MANAGER PROJECT ENGINEER DESIGNER
2
EM
TING EXIS IDE ' 0 2 W RM STO R E SEW T MEN E S EA
(585) 325-1000 FAX: (585) 325-1691
1
TRANS.
TEL
242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
NO. DATE BY
28 LF 8" CMP @ 0.25%
SMH RIM=386.31' N.INV=378.21' S.INV=378.21'
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
14C
MARITIME DRIVE
LE
% " RCP @ 7.85
107 LF 24
HO
78 LF 24" CMP @ 26.90%
3"
DRAINAGE INLET MH TG=358.66' E.INV=350.46' W.INV=350.46'
CP
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 DEMO.DWG
DRAINAGE MH RIM=377.86' S.INV=372.26' E.INV=358.86' W.INV=358.86'
2" F1 2L 13
Jacob Lewis
.5'Ø ' CS 4 382.84 4' = 8 IM R 379. 84' = V N.IN V=379. SE.IN
CB TG=417.32' E.INV=413.47' W.INV.=413.57'
28 LF 8" CMP @ 0.39%
CLIENT:
C 103 18C
DATE:
OCTOBER 2024
HORIZONTAL SCALE DRAINAGE INLET MH TG=393.92' N.INV=387.52' E.INV=387.67' S.INV=388.32'
30
P CM 18"
SMH RIM=395.49' N.INV=377.59' S.INV=377.59' E.INV=387.19' E.INV=379.49' W.INV=379.49'
DRAINAGE INLET MH TG=395.53' NE.INV=390.88' E.INV=388.43' W.INV=388.43'
ILE 8" T
31 LF 12" CPP @ 3.42%
SMH RIM=394.74' N.INV=380.39' E.INV=380.39'
CB TG=359.59' SW.INV=391.94'
210 LF 15" CMP @ ?%
HYD WV WV
41 LF 8" PVC @ 2.20%
42 LF 12" CMP @ 6.26%
CORE AND CONNECT TO EX. MANHOLE WITH OUTSIDE DROP CONNECTION INV=379.38
35 LF 8" PVC @ 1.11%
MC EWEN DRIVE
SMH RIM=396.03' NE.INV=387.58' W.INV=387.58'
191 LF 15" CMP @ 4.83% 15" CMP
CB TG=409.96' N.INV=405.86'
FORCE MAIN
SMH RIM=397.78' N.INV=377.88' S.INV=377.88'
DRAINAGE INLET MH TG=410.20' NW.INV=405.25' S.INV=405.30'
4" DIP CL 52 ZINC COATED COMBINED WATER SERVICE
S-2 (4' DIA MH) RIM=413.00 W INV=406.00
60
Dig Safely. New York
DRAINAGE INLET MH TG=424.36' E.INV=418.66' W.INV=418.66'
FORCE MAIN
S-1 (4' DIA MH) RIM=409.52 E INV=402.50 NW INV=402.25
30
If you excavate anywhere in New York State, except NYC or Long Island, call
HH WATER METER
49 LF 36" RCP @ 0.59%
TG=394.85' SW.INV =390.95'
46 LF 15" CMP @ 10.15%
24 LF 15" CMP @ 2.33% 2" PE GAS MAIN
8" VC P
55 LF 15" CMP @ 1.38%
15
1"=30'
DRAINAGE INLET MH TG=422.99' E.INV=413.99' W.INV=413.99'
9 LF 15" CMP @ 1.11%
DMH RIM=410.05' S.INV=405.15' E.INV=404.75' W.INV=404.55'
0
1-800-962-7962 i-Notice = www.DigSafelyNewYork.com
PROPOSED VALVE (TYP)
LEGEND PROPERTY BOUNDARY
274 LF 8" PVC SAN @ 1.28%
117 LF 36" RCP @ 0.04%
CB TG=423.24' S.INV=418.79'
4" SDR 21 SANITARY LATERAL @ 2.00% MIN
S
S
DA-3.2 (2'X2' CB) TG=396.50 E INV=392.93 S INV=392.93
W
W
W
W
W
DB-5 (YARD DRAIN) RIM=407.50
EXISTING STORM SEWER, CB & MH
DB-3 (YARD DRAIN) TG=418.50
27 LF 12" HDPE STM.@ 0.25%
168 LF 12" CPP @ 3.31%
W
4" SDR 21 SANITARY LATERAL @ 2.00% MIN
S LP HHE
84 LF 12" HDPE STM.@ 0.25%
CORE AND CONNECT TO EXISTING CATCH BASIN
X
CB TG=417.43' E.INV=413.68'
DMH RIM=421.38' N.INV=413.23' S.INV=412.83' W.INV=412.43'
8" SDR 21 PVC STORM LATERAL (TYP) LP HHE
DB-7 (YARD DRAIN) RIM=407.50 DA-8 (2'X2' CB) TG=401.50 N INV=397.00
PROPOSED UNDERDRAIN 130 LF 24" HDPE STM.@ 1.08% DA-5.1 (2'x'2 CB) TG=400.50 S INV=396.73 NW INV=396.73
LE
HO
4" DIP CL 52 ZINC COATED COMBINED WATER SERVICE
6" SDR-21 STORM DRAIN (TYP)
2L 2"
F1
DA-5.2 12" END SECTION INV=396.80
P@
CP
Passero Associates
W
DA-2 (4' DIA INLET MH) RIM=391.50 NW INV=375.00 SW INV=375.00
PE HD
W
PROPOSED UNDERDRAIN
PE HD % " 5 12 0.2 LF .@ 28 TM S
DA-1 12" END SECTION INV=356.00 CONNECT TO PIPE STUB AT 379.72
H
W
62 LF 12" CPP @ 4.69%
29 LF 12" HDPE STM.@ 10.92%
HHE
W
PROVIDE THRUST BLOCKS AT TEES AND BENDS (TYP) PROPOSED 58 LF 2DEDICATED 4" CPP 8" WATERMAIN @ 4.9
CONNECT TO EXISTING WATERMAIN WITH TS&V.
' DMH 395.30 65' = RIM V=387. ' NE.IN =387.15 ' 5 V E.IN =387.1 V IN . W
CB 403.23' 88' TG= V=399. W.IN
PM GAS N-S
UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
DMH TG=412.28' N.INV=DID NOT MEASURE N.INV=408.48' E.INV=407.98' W.INV=407.98'
UTILITY PLAN
TOWN ASSESSOR
FIRE MARSHAL
WATERVIEW PHASE III WEBSTER, NY
WEBSTER SEWER DISTRICT
VE
' V= N.IN =378.43 ' V 3 N 6 I . . S 380 8' = V 5 N E.I 82. 8' V=3 E.IN =380.7 V W.IN
HHE @ PP " C ED% 4 2 IN LF 85 ETERM D UN
9.04%
15
LP
5%
DC-1 (6' DIA WATER QUALITY UNIT) RIM=396.00 NW INV=381.24 ' SMH 391.28 43' = RIM 378.
W INT
O
P W O ILL
7 8
TOWN/CITY: WEBSTER HIGHWAY SUPERINTENDENT
DRI
DD-1 (2'X2' CB) RIM=386.00 NE INV=382.93 NW INV=382.93
P@ 8" CP 8 LF 1
ME
MB
W P@ CM F 8" INED% L 9 4 M ETER UND
6
COMMISSIONER OF PUBLIC WORKS
AY
DMH390.78' 3' TG= =382.2 ' V N.IN =384.78 8' 6 V IN . 382. E INV= . W S
APPROVALS PLANNING BOARD CHAIRMAN
HHE
RITI
LP
DD-2 (2'X2' CB) WV RIM=386.00 HYD SW INV=383.00
4 5
HHE
Y
DESCRIPTION
15" CMP
MA
CB TG=386.96' N.INV=384.46'
P
D
D
CM F 8" 37 L 97% . 9 @
CB 83' 6 39 . TG= 92.33' V=3 W.IN
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
3
46 LF 8" CMP @ 5.43%
CONTRACTOR TO COORDINATE PEDESTAL RELOCATION WITH RG&E
PROJECT MANAGER PROJECT ENGINEER DESIGNER
2
TRANS CTV
CB TG=413.00' E.INV=411.10' PM GAS N-S
4" DIP CL 52 ZINC COATED COMBINED WATER SERVICE
(585) 325-1000 FAX: (585) 325-1691
1
PM GAS E-W
DMH401.19' 9' TG= =396.1 ' V E.IN =393.69 ' V E.IN =393.69 V W.IN
242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
NO. DATE BY
LP
W ND NE ECPP ' 24" 381.13 CPP INV= ND 12" CO NE E 1.55 38 CPP INV= LF 24" 66 67% @ 1.
HHE
CB TG=413.83' E.INV=411.03' S.INV=410.98'
EM
CONNECT TO EX. SANITARY MAIN WITH INSERT-A-TEE (TYP)
202 LF 36" RCP @ 0.11%
LL WA E % GL 9.50 IN " S .@ 1 2 1 TM LF S
TEL
W
97
CTV
4" SDR 21 SANITARY LATERAL @ 2.00% MIN
100 LF 12" HDPE STM.@ 13.90%
HHE
TRANS.
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
183 LF 12" CPP @ UNDETERMINED%
28 LF 8" CMP @ 0.25%
4" SDR 21 SANITARY LATERAL @ 2.00% MIN
SMH RIM=386.31' N.INV=378.21' S.INV=378.21'
CLIENT:
MONROE COUNTY HEALTH DEPT.
2%
5.4
E DP "H 12 .25% 0 LF 57 M.@ ST
OS-1 (2'X2' CB) RIM=355.70 NW INV=350.60 S INV=353.50
CB TG=417.32' E.INV=413.47' W.INV.=413.57'
28 LF 8" CMP @ 0.39%
MARITIME DRIVE
YD
X
X
HYD
105 LF 12" HDPE STM.@ 0.25%
3"
CMP @ 26.90%
WV
X
4" SDR 21 SANITARY LATERAL @ 2.00% MIN
13
P @ 7.85% 107 LF 24" RC
W
CO
DA-4 (2'X2' CB) TG=396.50 NE INV=393.00 W INV=393.00 78 LF 24"
23 LF 12" HDPE STM.@ 17.74%
TOWN OF WEBSTER
DB-1 (YARD DRAIN) TG=416.50
X
DRAINAGE MH RIM=377.86' CONNECT TO EXISTING INLET S.INV=372.26' E.INV=358.86' MANHOLE AT 350.46 W.INV=358.86'
X
4" DIP CL 52 ZINC COATED COMBINED WATER SERVICE
.5'Ø ' CS 4 382.84 4' = IM 79.8 4' R 3 = V N.IN V=379.8 SE.IN
RIM=396.50 N INV=388.86 E INV=388.86 SE INV=388.86
Jacob Lewis
X
W
EXISTING SIGN
N.T.S.
X
X
PE 12" HD 67 LF 0.25% STM.@
E DP "H % 2 F 1 2.19 3L 14 TM.@ S
Y
WA
X
W
DB-6 (YARD DRAIN) RIM=391.50 DA-3 (4' DIA INLET MH)
10/29/2024 11:09 AM
X
W
W
INT
STAMP:
X
E DP "H % 2 1 .25 LF 0 92 M.@ T S
PO
GE DRID WIN DR.
77 LF 12" HDPE STM.@ 0.25%
X
PROPOSED HYDRANT ASSEMBLY
DA-3.1 (4' DIA INLET MH) RIM=397.00 N INV=389.03 S INV=389.03
WILLOW
EXISTING GAS MAIN
LOCATION SKETCH
X
DA-5 (2'X2' CB) TG=400.50 NW INV=396.12 SE INV=396.47 NE INV=396.37 SW INV=396.12
196 LF 36" RCP @ 0.14%
EXISTING LIGHT POLE
X
W
H
42 L STM F 12 .@ " HD 0.2 PE 5%
SITE
W
X
DA-5.3 (2'X2' CB) TG=398.50 N INV=396.22 SE INV=396.22
PROPOSED UNDERGROUND ELECTRIC PROPOSED LIGHT POLE
4" DIP CL 52 ZINC COATED COMBINED WATER SERVICE
DA-6 (2'X2' CB) TG=401.50 E INV=396.60 SW INV=396.60
4" DIP CL 52 ZINC COATED COMBINED WATER SERVICE
4" DIP CL 52 ZINC COATED COMBINED WATER SERVICE
E
MARITIME DR.
DB-4 (YARD DRAIN) RIM=407.50
70 LF 8" PVC STM.@ 0.40%
4" SDR 21 SANITARY LATERAL @ 2.00% MIN
MC EWEN DR.
E
METER AND BACKFLOW INSIDE BUILDING (TYP)
D OA
DA-5.4 (YARD DRAIN) RIM=398.50 S INV=396.50
EXISTING ELECTRIC LINE
YR BA
178 LF 12" HDPE STM.@ 2.19%
PROPOSED SANITARY SEWER & MH
DB-2 (YARD DRAIN) TG=418.50
DA-7 (2'X2' CB) TG=401.50 S INV=396.79 W INV=396.79
SMH RIM=398.78' N.INV=377.93' S.INV=377.93'
EXISTING SANITARY SEWER & MH
S
24 LF 8" PVC SAN @ 95.89%
PROPOSED WATER SERVICE HYDRANT AND VALVE PROPOSED WATER LATERAL
W
WV
4" SDR 21 SANITARY LATERAL @ 2.00% MIN
CO
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 UTIL.DWG
PROPOSED STORM SEWER, CB & MH EXISTING WATER SERVICE & VALVE
DB-8 (4' DIA DRY WELL) RIM=385.00
DRAINAGE INLET MH TG=358.66' E.INV=350.46' W.INV=350.46'
ST D
HYD
DA-3.3 (2'X2' CB) TG=396.50 W INV=393.00
D
EXISTING EASEMENT
MONROE
NY
PROJECT NO.:
20243903.0002
MONROE COUNTY WATER AUTHORITY
DRAWING NO.:
C 104 DATE:
OCTOBER 2024
HORIZONTAL SCALE DRAINAGE INLET MH TG=393.92'
30
0
15
30
60
SMH RIM=395.49' DRAINAGE INLET MH TG=395.53'
1"=30'
DRAINAGE INLET MH TG=422.99' DMH RIM=410.05'
LEGEND PROPERTY BOUNDARY
HYD WV WV
EXISTING EASEMENT EXISTING MAJOR CONTOUR
HH WATER METER
EXISTING MINOR CONTOUR
MC EWEN DRIVE
SMH RIM=396.03'
CB TG=409.96'
DRAINAGE INLET MH TG=424.36'
DRAINAGE INLET MH TG=410.20'
EXISTING SPOT ELEVATION
TG=394.85'
5
400
402
SF
412
S
CB TG=423.24'
420
408
PROPOSED HYDRANT & VALVE HYD
419
409 DB-5 TG=407.50 YARD DRAIN
X
Y
WA
TOWN OF WEBSTER
LOCATION SKETCH N.T.S.
X
X
W/O=409.0'
STAMP:
X
417
WV
X
HYD
DB-1 TG=416.50 YARD DRAIN
X X
398
DA-8 TG=401.50 2'X2' CB
.5'Ø ' CS 4 382.84 = IM R
397
41
408
6
40
408
403 4 40
FP=
SF DRAINAGE INLET MH TG=358.66'
400
SF
410
'
03.0
FP=4
400
Jacob Lewis
.0'
39 7
41 1
6
5 6
CB TG=413.00'
7 8 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
HHE
39 4
Y
A TW N I O WP
ILLO
W
CB TG=386.96'
GRADING & EROSION CONTROL
HHE
39 8
DD-2 TG=386.00 2'X2' CB
38
DESCRIPTION
4
6
SF
388
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
3
40
5
385
PROJECT MANAGER PROJECT ENGINEER DESIGNER
2
TRANS CTV
3
365
HHE
40
SF
SF
360
(585) 325-1000 FAX: (585) 325-1691
NO. DATE BY
7
40
355
356
398
356
SF
396
395 393
7
38
DMH TG=412.28'
APPROVALS CB 403.23' TG=
LP
HHE
PLANNING BOARD CHAIRMAN
WATERVIEW PHASE III WEBSTER, NY
MA
WV HYD
DMH390.78' TG=
DA-1 12" END SECTION INV=356.00 CONTRACTOR TO USE BIONET S150BN ROLLED EROSION CONTROL BLANKETS BY NORTH AMERICAN GREEN OR APPROVED EQUAL '
SMH 391.28 = RIM
COMMISSIONER OF PUBLIC WORKS
TOWN/CITY: WEBSTER TOWN ASSESSOR
MONROE
NY
PROJECT NO.:
E RIV
' DMH 395.30 = RIM
ED
M RITI
DD-1 LP TG=386.00 HE 2'X2' CB H
CB TG=413.83'
LP
40
404
401 400
STABILIZED CONSTRUCTION ENTRANCE
PROPOSED RIP RAP OUTLET PROTECTION
HHE
242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
399 D
388
SF
DMH401.19' TG=
397
39 0
Passero Associates
1
408
402
390
389
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
EM
DC-1 RIM=396.00 6' DIA WATER QUALITY UNIT
356.5
CLIENT:
CTV TEL
402
391
RIP RAP LINED EMERGENCY SPILLWAY ELEV: 356.00
1 41
412
' 05.0
414 413
409
'
07.0
FP=4
398
SF
SF 392
DA-2 TG=391.50 4' DIA INLET MH
9.0'
FP=4
FP=
0
37
393
0 FP=4
2
397
DA-5.2 12" END SECTION INV=396.80
394
SMH RIM=386.31'
400
40
399
398
SF
SILT FENCE (TYP.)
OS-1 TG=355.70 2'X2' CB
36 5
398 39 9
401
DA-5.1 TG=400.50 2'x'2 CB
DA-3 TG=396.50 4' DIA INLET MH
360
415
.0'
395
CB TG=417.32'
LP HHE
5 406
DRAINAGE MH RIM=377.86'
7
DB-7 TG=407.50 YARD DRAIN
401
396
DA-4 TG=396.50 2'X2' CB
375
402
0'
SF
. 403
399
FP=
X
DMH RIM=421.38'
MARITIME DRIVE
401
CB TG=417.43'
407
38
FP=400.0'
PROPOSED 1' BROADSTONE 6" MEDLEY BY KEYSTONE RETAINING WALL (TYP)
41
6 5 38
7 38 9
X
389
X
X
396
395
394
396
380
CONTRACTOR TO USE BIONET S150BN ROLLED EROSION CONTROL BLANKETS BY NORTH AMERICAN GREEN OR APPROVED EQUAL
10/29/2024 11:10 AM
INT
9
X
402
393
SF
PROPOSED 4' WIDE STRONG STONE RETAINING WALL (TYP)
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 GRAD.DWG
PO
39 7
385
PROVIDE PLASTIC WATERPROOF MEMBRANE IN BERM ON SAND FILTER
WILLOW
X
398
355.00
MC EWEN DR.
41
X
EXISTING SIGN
GE DRID WIN DR.
409
DA-7 TG=401.50 2'X2' CB
X
X 403
X=
DA-5 TG=400.50 2'X2' CB
397
.0'
EXISTING LIGHT POLE
418
402
400
DA-3.1 TG=397.00 4' DIA INLET MH
401
401
DA-5.3 TG=398.50 2'X2' CB
PROPOSED LIGHT POLE
SITE
410
402 401
401
402
FP=398.0'
PROPOSED SANITARY SEWER & MH
FP=420.0'
SF
SF 38
403 402
FP=396.0'
SF
DB-6 TG=391.50 YARD DRAIN
408
404
SF FP=394.0'
DB-4 TG=407.50 YARD DRAIN
DA-6 TG=401.50 2'X2' CB
D
DB-8 RIM=385.00 4' DIA DRY WELL
S
DB-2 TG=418.50 YARD DRAIN
419
FP=418.0'
SF
398.0
EXISTING SANITARY SEWER & MH
D OA
FP=409.0
399
399
W/O=389.0'
S
YR BA
FP=405'
DB-3 TG=418.50 YARD DRAIN LP HHE
W/O=411.0'
SF
398
WV
SMH RIM=398.78'
PROPOSED SILT SAC OR SILT FENCE
PROPOSED STORM CB & END SECTION
1
0
W/O=387.0'
SF
41
404
DA-5.4 TG=398.50 YARD DRAIN
PROPOSED SPOT ELEVATION
EXISTING STORM MH, CB & END SECTION
41
W/O=385.0'
492X7
PROPOSED INLET PROTECTION
421
DA-3.3 TG=396.50 2'X2' CB
PROPOSED MINOR CONTOUR
409
399
397
521
PROPOSED CHECK DAM, RIP RAP
408
403
S
S-2 RIM=413.00 4' DIA MH
413
401
PROPOSED MAJOR CONTOUR
TC:492.9 BC:492.4
414
DA-3.2 TG=396.50 2'X2' CB
40
407
396
SF
SF
SF
SF
406
S-1 RIM=409.52 4' DIA MH
SF
SF
SF
SF
SMH RIM=397.78'
520
MARITIME DR.
SMH RIM=394.74'
20243903.0002 FIRE MARSHAL
DRAWING NO.:
C 105 HIGHWAY SUPERINTENDENT
DATE:
OCTOBER 2024
HORIZONTAL SCALE
REFER TO SHEET C201 FOR LANDSCAPING NOTES AND SHEET C 204 FOR FOUNDATION PLANTING PLANS AND PLANT SCHEDULE
30
15
0
30
60
1"=30'
HYD WV WV HH WATER METER
GT 2
MC EWEN DRIVE
CV 1
AG 1
CV 1
AG 1
GT 3
CV 1
SV 1 X
X
X
X
X
X
X X
CC 1
X
HYD
X
OHD
OHD
OHD
OHD
OHD
OHD
OHD
OHD
CV 1
WV
OHD
X
OHD
OHD OHD OHD
OHD OHD
OHD
X
X
X
X
X
X
X
X
X
X X
CC 1 WV
LUMINAIRE SCHEDULE
OHD
X
X
X
N.T.S. STAMP:
X
X
LOCATION SKETCH
X X
OHD
OHD X
X
TOWN OF WEBSTER
X
X
X
X
1.0 FOOTCANDLES 0.5 FOOTCANDLES
X
X
0.25 FOOTCANDLES X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
NS 3
X
LP HHE
X
D OH D OH
X
LXD DAYFORM BY STREETWORKS DARK SKY POST TOP FIXTURE
X X
X
MARITIME DRIVE
X
X
X
OH
X
D
X X
X X
X
D OH
X
OHD
17' BLACK TAPERED FIBERGLASS POLE
HHE
TRANS.
2.
CTV
OHD OHD
TEL
HHE
TRANS CTV
FINISH GROUND
FOUNDATIONS SHALL EXTEND BELOW FROST DEPTH PER LOCAL CODES.
X
X
LP
X
X
OHD X
D
X
D OH
X
X X
X X
X
COLONIAL RESIDENTIAL LANTERN
X X
N.T.S.
HHE
X
HHE
P LOW
WIL
DESCRIPTION
1 2 3 4 5
LANDSCAPING & LIGHTING PLAN WATERVIEW PHASE III WEBSTER, NY
O
LP HHE
TOWN/CITY: WEBSTER COUNTY: MONROE
E RIV
D ME
MB
Y WA T IN
RITI
HHE
WV HYD
NO. DATE BY
MA
LP
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
12"
CV 1
GT 1
X
PROJECT MANAGER PROJECT ENGINEER DESIGNER
8
DIRECT BURY BASE PER MANUFACTURING RECOMMENDATION
CV 1
D OH
X
(585) 325-1000 FAX: (585) 325-1691
7
OHD
X
242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
6
EM
D OH
X
X
OHD
OHD
X
X
OHD
X
X
OHD
X
X
D OH
X
X
X
X
D
10/29/2024 11:10 AM
X
G RY TO DIN 2-S BUIL SED ME PO HO PROTOWN IT UN
OH
X
RY STO ILDING 2 D U OSE OME B P O H PR OWN T T I N 10 U
1. FOUNDATION SHOWN IS A TYPICAL DESIGN. WIND LOADS OF MORE THAN 90 MPH AND UNSTABLE SOIL MAY REQUIRE AN ALTERNATE DESIGN. CONTRACTOR SHALL ADVISE ENGINEER OF UNSTABLE SOIL CONDITIONS.
OHD
X
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 LAND_ LIGHT.DWG
X
10
X
Jacob Lewis
X
MS 1
Passero Associates
48"
X
SV 2
AR 1
THE CONTRACTOR SHALL PROVIDE A PRIVATE ELECTRICAL CONDUIT/CIRCUIT AND METERED PANEL FOR PROPOSED POLE MOUNTED LIGHT FIXTURE AS SHOWN PER THIS PLAN.
UTLD TRADITIONAIRE LED DOWNLIGHT MODEL NO. UTLD-AF24-30-5LTD-U-5WQ
14'
X
X
X
X
CLIENT:
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
X
X
PROPOSED BIO-RETENTION AREA
MS 1
X
Y
WA
X
X ITY UN MM ER CO CENT SF 500 ±1,
X
X
MS 1
OH
INT
LIGHTING POLE W/ ISO FOOT CANDLE LINES-
X
PROPOSED SAND FILTER
PO
GE DRID WIN DR.
HYD
X
X
X
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
X
X
K AR G P SF DO ,500 ±1
X
X
X
X
X
MS 1
X
X
X
OHD
X
ALL LEBRT K C PI OU C
X
OHD
X
X
X
X
X
DHO
OHD
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
X
X
DHO
X
X
X
PROPOSED BIO-RETENTION AREA
X OHD
X
X
X
SV 1
PROPOSED BIO-RETENTION AREA
OHD
X
X
X
X
X
X
X
OHD
X
X
X
X
X
X
X
OHD
X
WILLOW
X
X
X
X
X
X
AR 1 CC 1
SITE
X
X
SV 1
DHO
DHO
DHO
DHO
MS 1
MC EWEN DR.
D OA
X X
OHD
OHD
X
PROPOSED 2-STORY 6 UNIT TOWNHOME BUILDING
OHD
OHD
SV 1
PROPOSED 2-STORY 10 UNIT TOWNHOME BUILDING
YR BA
LP HHE
MARITIME DR.
AR 1
NY
PROJECT NO.:
APPROVED BY APPROVED BY
PLANNING BOARD CHAIRMAN
COMMISSIONER OF PUBLIC WORKS
20243903.0002
DATE
DRAWING NO.:
C 106
DATE DATE:
OCTOBER 2024
1. PRIOR TO THE START OF UTILITY INSTALLATION THE CONTRACTOR AND SUBCONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL UTILITY CONNECTIONS WITH MECHANICAL/ARCHITECTURAL DRAWINGS FOR INCLUDING BUT NOT LIMITED TO VERTICAL AND HORIZONTAL LOCATION, PENETRATIONS, AND SIZES. THE CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION TO PROCEED WITH UTILITY INSTALLATION BY THE OWNERS ONSITE REPRESENTATIVE UPON COMPLETION OF COORDINATION WITH CONTRACTORS, AND PLANS. 2. THE DEVELOPER AND HIS/HER CONTRACTOR IS RESPONSIBLE FOR COORDINATING GAS, ELECTRICAL, CABLE, TELEPHONE AND ANY OTHER UTILITIES NOT SPECIFICALLY SHOWN WITHIN THIS PLAN SET WITH APPROPRIATE AGENCY. PASSERO ASSOCIATES ASSUMES NO RESPONSIBILITY FOR THE DESIGN OR PERFORMANCE OF UTILITIES NOT SPECIFICALLY SHOWN WITHIN THIS PLAN SET. 3. PRIOR TO THE START OF UTILITY INSTALLATION THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES VERTICALLY AND HORIZONTALLY AND COORDINATE WITH EXISTING UTILITIES SHOWN ON THE PLANS AND REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. THE CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION TO PROCEED WITH UTILITY INSTALLATION BY THE OWNERS ONSITE REPRESENTATIVE UPON COMPLETION EXISTING UTILITY VERIFICATION. 4. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH SITE CONTRACTOR/PLUMBER & SEWER CONTRACTOR TO PREDETERMINE THE NECESSARY WYE & CLEANOUT LOCATION ON THE STORM SEWER SYSTEM. THE STORM SEWER SYSTEM IS RECOMMENDED AND MAY BE MODIFIED TO PROVIDE ADEQUATE ROOF DRAINAGE CONNECTIONS. 5. THRUST BLOCKS ON THE WATERMAIN ARE REQUIRED AT BENDS, TEES OR PLUGS. SEE DETAIL SHEETS FOR THRUST BLOCK DETAILS.
1.
MAXIMUM ALLOWABLE INFILTRATION OR EXFILTRATION SHALL NOT EXCEED 100 GALLONS PER INCH DIAMETER PER MILE OF PIPE PER DAY FOR THE SANITARY SEWER. IF AN AIR TEST IS USED, THE TEST AS A MINIMUM SHALL CONFORM TO THE PROCEDURE DESCRIBED IN ASTM DESIGNATION C828-86 ENTITLED PRACTICE FOR LOW-PRESSURE AIR TEST OF VITRIFIED CLAY PIPE LINES. SANITARY MANHOLES SHALL BE VISUALLY INSPECTED AND TESTED FOR LEAKAGE BY EXFILTRATION OR VACUUM. VACUUM TESTING OF MANHOLES SHALL COMPLY WITH THE METHOD OUTLINED IN THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION - TECHNICAL INFORMATION PAMPHLET (TIP) NO. 15 (LATEST REVISION).
2. FLOOR DRAINS, IF CONSTRUCTED IN THE PROJECT, MUST BE CONNECTED TO THE SANITARY SEWER. NOTE: FLOOR DRAINS DO NOT INCLUDE FOUNDATION OR FOOTER DRAINS INSTALLED TO INTERCEPT UNCONTAMINATED GROUND WATER. ALL DISCHARGES FROM THE FLOOR DRAINS TO THE SANITARY SEWER MUST COMPLY WITH THE EFFLUENT LIMITS OF THE LOCAL AND/OR THE MONROE COUNTY SEWER USE LAW. 3. DEFLECTION TESTS SHALL BE PERFORMED ON ALL FLEXIBLE PIPE. THE TEST SHALL BE CONDUCTED AFTER THE FINAL BACKFILL HAS BEEN IN PLACE AT LEAST 30 DAYS. NO PIPE SHALL EXCEED A DEFLECTION OF 5%. IF THE DEFLECTION TEST IS TO BE RUN USING A RIGID BALL OR MANDREL, IT SHALL HAVE A DIAMETER EQUAL TO 95% OF THE INSIDE DIAMETER OF THE PIPE. THE TEST SHALL BE PERFORMED WITHOUT MECHANICAL PULLING DEVICES. 4. MINIMUM VERTICAL SEPARATION BETWEEN WATER MAINS AND SEWER LINES SHALL BE 18 INCHES MEASURED FROM THE OUTSIDE OF THE PIPES AT THE POINT OF CROSSING. ONE FULL STANDARD LAYING LENGTH OF WATER MAIN PIPE SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. IN ADDITION, WHEN THE WATER MAIN PIPELINE PASSES UNDER A SEWER, ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECTED FILL) SHALL BE PROVIDED FOR THE SEWER TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING OF THE SEWER ON THE WATER MAIN. MINIMUM HORIZONTAL SEPARATION BETWEEN PARALLEL WATER MAINS PIPES AND SEWER PIPES (INCLUDING MANHOLES AND VAULTS) SHALL BE 10 FEET MEASURED FROM THE OUTSIDE OF THE PIPES, MANHOLES OR VAULTS.
STORM NOTES 1.
2.
FOUNDATION DRAINS SHALL BE CONNECTED TO STORM WATER SYSTEM VIA SUMP PUMPS. DOWNSPOUTS SHALL BE CONNECTED TO STORM SEWER WHERE APPLICABLE, WHERE NOTED ON THE PLANS DOWNSPOUTS SHALL DISCHARGE TO SPLASH BLOCKS. UPON COMPLETION OF SYSTEM INSTALLATION, THE MAIN SEWER SYSTEM AND LEADS TO STRUCTURES SHALL BE FLUSHED AND LAMPED OR MANDREL TESTED TO THE SATISFACTION OF THE MUNICIPALITY.
SANITARY NOTES 1. 2.
3.
4.
5.
SANITARY SEWERS AND APPURTENANCES SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE LATEST REGULATIONS OF THE STATE, COUNTY AND LOCAL MUNICIPALITY MATERIALS - MAINS - PIPING SHALL BE POLYVINYL CHLORIDE (PVC) WITH ENDS SUITABLE FOR ELASTOMERIC GASKET JOINTS, AND A MINIMUM WALL THICKNESS OF SDR-35. PIPING AND FITTINGS SHALL MEET: ASTM D-3034 (4" THRU 15") ASTM F-679 (18" THRU 48") - LATERALS - 4" MIN. INSTALLED AT 41" PER FOOT MIN. PIPING SHALL BE POLYVINYL CHLORIDE (PVC) WITH ENDS SUITABLE FOR ELASTOMERIC GASKET JOINTS, AND A MINIMUM WALL THICKNESS OF SDR-21. PIPING AND FITTINGS SHALL MEET ASTM D-2241. - JOINTING MATERIALS - SHALL BE BELL-AND-SPIGOT WITH INTEGRAL PUSH ON TYPE ELASTOMERIC GASKET JOINTS, GASKET MATERIAL TO BE NEOPRENE MEETING ASTM D-3212. - MANHOLES - SHALL BE PRECAST CONCRETE WITH NEOPRENE GASKETS MEETING ASTM C-478 & ASTM C-443.
VACUUM TESTING OF MANHOLES IS ALLOWED. THE CONTRACTOR IS CAUTIONED TO SPEAK TO THE SUPERINTENDENT OF SEWERS PRIOR TO COMMENCING WITH PLANS TO VACUUM TEST.
6. DEFLECTION TEST - TEN STATE STANDARDS. 6.A. DEFLECTION TESTS SHALL BE PERFORMED ON ALL FLEXIBLE PIPE. THE TEST SHALL BE CONDUCTED AFTER THE FINAL BACKFILL HAS BEEN IN PLACE AT LEAST 30 DAYS. 6.B. IF THE DEFLECTION TEST IS TO BE RUN USING A RIGID BALL OR MANDRELL, IT SHALL HAVE A DIAMETER EQUAL TO 95% OF THE INSIDE DIAMETER OF THE PIPE. THE TEST SHALL BE PERFORMED WITHOUT MECHANICAL PULLING DEVICES. 6.C. NO PIPE SHALL EXCEED A DEFLECTION OF 5%.
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 DETAILS.DWG
10/29/2024 11:10 AM
Jacob Lewis
7. 8.
9.
ALL SANITARY SEWER INSTALLATION SHALL BE MADE IN CONFORMANCE WITH THE SPECIFICATIONS, REGULATIONS, AND POLICIES OF THE PENFIELD SEWER DISTRICT. ALL HOUSE LATERALS SHALL HAVE A CLEANOUT AT THE PROPERTY LINE OR EASEMENT LINE. FLOOR DRAINS, IF CONSTRUCTED, SHALL BE CONNECTED TO THE SANITARY SEWER/COMBINATION SEWER. (FLOOR DRAINS DO NOT INCLUDE FOUNDATION/FOOTER DRAINS). ALL DISCHARGES TO THE SANITARY/ COMBINATION SEWER MUST COMPLY WITH THE EFFLUENT LIMITS OF THE LOCAL AND/OR THE MONROE COUNTY SEWER USE LAW.
10. SEPARATION - MINIMUM VERTICAL SEPARATION BETWEEN WATER MAINS AND SEWER LINES SHALL BE 18 INCHES MEASURED FROM THE OUTSIDE OF THE PIPES AT THE POINT OF CROSSING. ONE FULL STANDARD LAYING LENGTH OF WATER MAIN SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. IN ADDITION. WHEN THE WATER MAIN PASSES UNDER A SEWER ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECTED FILL) SHALL BE PROVIDED FOR THE SEWER TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING OF THE SEWER ON THE WATER MAIN. MINIMUM HORIZONTAL SEPARATION BETWEEN PARALLEL WATER MAINS AND SEWER PIPES (INCLUDING MANHOLES AND VAULTS) SHALL BE 10 FEET MEASURED FROM THE OUTSIDE OF THE PIPES. MANHOLES OR VAULTS. 11. 12. SEWER USE LAW: FLOOR DRAINS, IF CONSTRUCTED, SHALL BE CONNECTED TO THE SANITARY/COMBINATION SEWER. FLOOR DRAINS DO NOT INCLUDE FOUNDATION/FOOTER DRAINS. NOTE: ALL DISCHARGES TO THE SANITARY/COMBINATION SEWER MUST COMPLY WITH THE EFFLUENT LIMITS OF THE LOCAL AND OR MONROE COUNTY SEWER USE LAW.
FLOOR DRAINS, IF CONSTRUCTED, SHALL BE CONNECTED TO THE SANITARY/COMBINATION SEWER. FLOOR DRAINS DO NOT INCLUDE FOUNDATION/FOOTER DRAINS. NOTE: ALL DISCHARGES TO THE SANITARY/COMBINATION SEWER MUST COMPLY WITH THE EFFLUENT LIMITS OF THE LOCAL AND OR MONROE COUNTY SEWER USE LAW.
1.
1.
THE EARTHWORK CONTRACTOR IS RESPONSIBLE FOR ROUGH GRADING AND RE-SPREADING TOPSOIL IN ALL TURF AND LANDSCAPE AREAS (BEDS AND ISLANDS).
1.
CONTRACTOR SHALL OBTAIN ALL NECESSARY STATE AND LOCAL PERMITS REQUIRED. ALL CONSTRUCTION SHALL CONFORM TO APPLICABLE TOWN AND STATE DESIGN STANDARDS AND CODES.
2.
THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR FINE GRADING AND PREPARATION OF ALL LAWN AND LANDSCAPE AREAS.
2.
IT IS THE LANDSCAPE CONTRACTORS RESPONSIBILITY TO VISIT THE SITE PRIOR TO BID SUBMITTAL, TO BECOME FAMILIAR WITH EXISTING CONDITIONS AT THE SITE.
3.
STANDARDS SET FORTH IN THE "AMERICAN STANDARD FOR NURSERY STOCK", ANSI Z60.1 (LATEST EDITION) REPRESENT GUIDELINE SPECIFICATIONS ONLY AND SHALL CONSTITUTE THE MINIMUM QUALITY REQUIREMENTS FOR PLANT MATERIALS DELIVERED AND INSTALLED ON THIS PROJECT.
4.
ALL PLANTS MUST BE HEALTHY, VIGOROUS AND FREE OF PESTS AND DISEASE.
5.
ALL PLANTS MUST BE HARDY UNDER CLIMATE CONDITIONS THAT EXIST AT THE PROJECT SITE AND GROWN AT A NURSERY IN THE SAME HARDINESS ZONE AS THE PROJECT LOCATION.
SEEDING SHOULD BEGIN IMMEDIATELY UPON COMPLETION OF FINE GRADING. SEED SHOULD BE PRESSED INTO THE SOIL TO CREATE GOOD SEED-TO-SOIL CONTACT, NO DEEPER THAN THE THICKNESS OF THE SEED.
6.
ALL PLANTS MUST BE CONTAINER GROWN OR BALLED AND BURLAPPED AN MEET SIZE REQUIREMENTS AS INDICATED ON THE PLANT LIST.
8.
FERTILIZING, APPLY 10-0-10 FERTILIZER EVENLY AT THE RATE OF 20 POUNDS PER 1000 SQ FT. NO FERTILIZER CONTAINING PHOSPHORUS IS PERMITTED ON SITE.
7.
9.
SEED SHOULD BE APPLIED EITHER BY HAND BROADCASTING OR HYDRO SEEDING. TWO PASSES SHALL BE MADE IN PERPENDICULAR DIRECTIONS TO INSURE PROPER COVERAGE.
ALL TREES MUST BE STRAIGHT-TRUNKED, INJURY FREE, HAVE A FULL, SYMMETRICAL CROWN (HEAD) AND MEET ALL REQUIREMENTS SPECIFIED (E.G. SINGLE STEM, MULTI-STEM, HEAVY BRANCHED, ETC.).
8.
ANY PROPOSED DEVIATION TO THE LANDSCAPE PLAN MUST FIRST BE REVIEWED AND APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO THE INSTALLATION OF THE PROPOSED LANDSCAPING CHANGES.
9.
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL QUANTITIES SHOWN ON THESE PLANS. THE BID PRICE SUBMITTED WILL ASSUME THAT ALL PLANT MATERIALS DELINEATED WILL BE SUPPLIED AND INSTALLED. ANY DISCREPANCIES IN THE QUANTITIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND/OR DESIGN LANDSCAPE ARCHITECT (OWNER'S REPRESENTATIVE) PRIOR TO COMPLETING A BID PRICE.
THE WATER MAIN PIPELINE SHALL BE DISINFECTED EQUAL TO AWWA STANDARD FOR DISINFECTING WATER MAINS DESIGNATION C651 (LATEST REVISION). FOLLOWING DISINFECTION, THE WATER MAIN PIPELINE SHALL BE FLUSHED UNTIL THE CHLORINE CONCENTRATION IN THE WATER LEAVING THE MAIN IS NO HIGHER THAN THAT GENERALLY PREVAILING IN THE SYSTEM. ALL WATER MAIN PIPE FITTINGS NOT RECEIVING 24-HOUR CHLORINE DISINFECTION CONTACT TIME MUST BE SWAB-DISINFECTED 30 MINUTES PRIOR TO INSTALLATION. THE SAMPLING POINT(S) MUST BE DECONTAMINATED BY FLAMING. FIRE HYDRANTS ARE NOT ACCEPTABLE SAMPLING POINTS. THE MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH MUST RECEIVE AT LEAST 48-HOUR ADVANCE NOTIFICATION REQUESTING SAMPLING SERVICES. SAMPLING WILL NOT BE PERFORMED PRIOR TO RECEIPT FROM A NEW YORK STATE LICENSED OR REGISTERED DESIGN PROFESSIONAL (ENGINEER, ARCHITECT OR LAND SURVEYOR WITH A SPECIAL EXEMPTION UNDER SECTION 7208(N) OF THE EDUCATION LAW) CERTIFYING THAT THE WATER SUPPLY IMPROVEMENTS, TESTING AND DISINFECTION PROCEDURES WERE COMPLETED IN ACCORDANCE WITH THE APPROVED PLANS, REPORTS, SPECIFICATIONS AND ANY APPROVED AMENDMENTS. THE DEPARTMENT WILL COLLECT SAMPLES FOR FREE CHLORINE RESIDUAL, TOTAL COLIFORM, ESCHERICHIA COLI (E. COLI) AND TURBIDITY. THE WATER MAIN PIPE AND APPURTENANCES SHALL NOT BE PLACED INTO SERVICE UNTIL SO AUTHORIZED BY THE MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH.
2. MINIMUM VERTICAL SEPARATION BETWEEN WATER MAIN PIPELINES AND SEWER PIPELINES SHALL BE 18 INCHES MEASURED FROM THE OUTSIDE OF THE PIPES AT THE POINT OF CROSSING. ONE FULL STANDARD LAYING LENGTH OF WATER MAIN PIPE SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. IN ADDITION, WHEN THE WATER MAIN PIPELINE PASSES UNDER A SEWER, ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECTED FILL) SHALL BE PROVIDED FOR THE SEWER TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING OF THE SEWER ON THE WATER MAIN. MINIMUM HORIZONTAL SEPARATION BETWEEN PARALLEL WATER MAIN PIPES AND SEWER PIPES (INCLUDING MANHOLES AND VAULTS) SHALL BE 10 FEET MEASURED FROM THE OUTSIDE OF THE PIPES, MANHOLES OR VAULTS. 3. WHEN INSTALLING FIRE HYDRANTS, SHOULD GROUND WATER BE ENCOUNTERED WITHIN SEVEN (7) FEET OF THE FINISHED GRADE, FIRE HYDRANT WEEP HOLES (DRAINS) SHALL BE PLUGGED. 4. THE WATER MAIN PIPELINE AND APPURTENANCES SHALL BE PRESSURE/LEAKAGE TESTED IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE AWWA STANDARD C600, C602, C604, OR C605 (MOST RECENT VERSION AS APPLICABLE) OR IN ACCORDANCE WITH MORE STRINGENT REQUIREMENTS IMPOSED BY THE SUPPLIER OF WATER.
PUBLIC WATER SYSTEM NOTES
(OCTOBER 2021) 1. IN ACCORDANCE WITH SECTIONS 107-12 AND 209-3.01 OF THE NYSDOT STANDARD SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW THE EROSION AND SEDIMENT CONTROL PLAN INCLUDED IN THE CONTRACT DOCUMENTS, AND IF NECESSARY, MODIFY THE PLAN WITH THE CONTRACTOR'S INTENDED SEQUENCE AND TYPES OF OPERATIONS. THE CONTRACTOR'S MODIFIED EROSION AND SEDIMENT CONTROL PLAN SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL, ALONG WITH A PROGRESS SCHEDULE THAT ADDRESSES THIS WORK. 2. IN ACCORDANCE WITH SECTIONS 107-12 AND 209-3.01 OF THE NYSDOT STANDARD SPECIFICATIONS, THE CONTRACTOR SHALL DESIGNATE AN "EROSION AND SEDIMENT CONTROL SUPERVISOR" FOR THE PROJECT. THE SUPERVISOR SHALL BE RESPONSIBLE FOR IMPLEMENTING THE EROSION AND SEDIMENT CONTROL PLAN AND FOR INSPECTING AND MAINTAINING THE CONTROL MEASURES. THE NAME AND QUALIFICATIONS (TRAINING AND EXPERIENCE) OF THIS INDIVIDUAL SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO STARTING EARTHWORK.
WATER MAINS AND APPURTENANCES TO BE CONSTRUCTED IN ACCORDANCE WITH THE REGULATIONS AND SPECIFICATIONS OF THE MONROE COUNTY WATER AUTHORITY:
MATERIAL:
· WATER SERVICE(S) SHALL BE 1 INCH TYPE K COPPER FROM THE WATER MAIN TO THE CURB BOX AND 1 INCH (TYPE K SOFT COPPER OR PE #3408) FROM THE CURB BOX TO THE METER.
· WATER METER(S) SHALL BE LOCATED ON THE INTERIOR OF EXTERIOR WALLS IMMEDIATELY UPON SERVICE ENTRANCE INTO THE BUILDING(S). ON METERED SERVICES REQUIRING A 1 1/2-INCH OR LARGER METER A BYPASS AROUND THE METER IS REQUIRED.
· ALL GATE VALVES SHALL HAVE STAINLESS STEEL BODY AND BONNET BOLTS.
TESTS:
3. THE DESIGNATED "EROSION AND SEDIMENT CONTROL SUPERVISOR" SHALL NOTIFY THE ENGINEER IN ADVANCE OF ANY FIELD CHANGES TO THE EROSION AND SEDIMENT CONTROL MEASURES INDICATED IN THE CONTRACT DOCUMENTS. THE ENGINEER MAY REQUIRE THE CONTRACTOR TO SUBMIT A MODIFIED EROSION AND SEDIMENT CONTROL PLAN FOR APPROVAL PRIOR TO IMPLEMENTING ANY FIELD CHANGES. 4. THE SITE SHALL AT ALL TIMES BE GRADED AND MAINTAINED SUCH THAT ALL STORM WATER RUNOFF FROM DISTURBED AREAS IS DIVERTED TO SOIL EROSION AND SEDIMENT CONTROL DEVICES BEFORE ENTERING A WATER BODY OR WETLAND.
· HEALTH SAMPLE. THE WATER MAIN SHALL BE DISINFECTED EQUAL TO AWWA STANDARD SPECIFICATIONS, DESIGNATION
5. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY SOIL DISTURBANCE FOR WHICH THEY ARE INTENDED AND SHALL REMAIN IN PLACE UNTIL SOILS ARE PERMANENTLY STABILIZED. 6. UNDER NO CONDITION SHALL DISCONTINUED CONSTRUCTION ACTIVITIES IN AREAS WITH SOIL DISTURBANCES BE LEFT FOR A PERIOD OF GREATER THAN 7 DAYS WITHOUT TEMPORARILY STABILIZING THOSE AREAS WITH TEMPORARY SEED AND MULCH. MAINTENANCE OF THOSE AREAS SHALL INCLUDE RESEEDING AND REMULCHING AS NEEDED TO ESTABLISH A SATISFACTORY STAND OF GRASS. THERE SHALL BE NO ADDITIONAL PAYMENT FOR RESEEDING AND REMULCHING. NO WET OR FRESH CONCRETE, LEACHATE, MATERIAL, OR DEBRIS SHALL BE ALLOWED TO ESCAPE INTO A WATER BODY OR WETLAND, NOR SHALL WASHINGS FROM CONCRETE TRUCKS, MIXERS OR OTHER DEVICES BE ALLOWED TO ENTER A WATER BODY OR WETLAND. ANY MATERIAL OR DEBRIS ACCIDENTALLY DROPPED INTO THE CHANNEL SHALL BE IMMEDIATELY AND COMPLETELY REMOVEDAND DEPOSITED IN AN UPLAND AREA. 7. THE CONTRACTOR SHALL COVER TEMPORARY STOCKPILES OF ERODIBLE MATERIAL (SUCH AS TOPSOIL OR EARTH FILL) WITH POLY SHEETING, OR RING THE STOCKPILES WITH SILT FENCE TO CONTROL EROSION. POLY SHEETING SHALL COMPLETELY COVER THE STOCKPILE AND BE SECURELY ANCHORED AT ALL TIMES. ANY POLY SHEETING OR SILT FENCE THAT IS DAMAGED SHALL BE PROMPTLY REPAIRED OR REPLACED AS DIRECTED BY THE ENGINEER. RINGED STOCKPILES EXPOSED OR EXPECTED TO BE EXPOSED FOR LONGER THAN 7 CALENDAR DAYS SHALL IMMEDIATELY BE STABILIZED WITH APPROPRIATE MEASURES. THE COST OF COVERING AND RINGING/STABILIZING STOCKPILES SHALL BE INCLUDED IN THE PRICE BID FOR THE CORRESPONDING STOCKPILED MATERIAL. 8. DUST CONTROL MEASURES SHALL BE APPLIED AS NEEDED. SWEEP ROADWAYS WHEN THEY BECOME SEDIMENT LADEN. MINIMIZE DISTURBED AREAS, APPLY TEMPORARY SOIL STABILIZATION PRACTICES SUCH AS MULCHING, SEEDING, AND SPRAYING WATER. WATER SHALL BE SPRAYED AS NEEDED BUT AVOID EXTRA SPRAYING WHICH COULD CREATE RUNOFF AND EROSION PROBLEMS.
1.
2. 3. 4.
TILL COMPOST INTO SUBSOIL TO A DEPTH OF AT LEAST 12" USING CAT-MOUNTED RIPPER, TRACTOR MOUNTED DISC, OR TILLER, MIXING, AND CIRCULATING AIR AND COMPOST INTO SUBSOILS. ROCK-PICK UNTIL UPLIFTED STONE/ROCK MATERIALS OF 4" AND LARGER ARE CLEANED OFF SITE. APPLY TOPSOIL TO A DEPTH OF 6 INCHES ON ALL AREAS BEING RETURNED TO GRASS. VEGETATE AS REQUIRED BY APPROVED PLAN.
3.
REMOVE ALL EXISTING VEGETATION DURING GRADING PROCESS.
4.
APPLY MINIMUM OF SIX (6) INCHES OF CLEAN TOPSOIL (IMPORTED OR SCREEN ON-SITE) AND FINE GRADE, LEAVING TOPSOIL IN A LOOSE AND FRIABLE CONDITION FOR SEEDING.
5.
LIME SOIL OR ADD OTHER ORGANIC AMENDMENTS AS NECESSARY TO ACHIEVE A SOIL pH BETWEEN 5.5 - 7.0.
6.
LANDSCAPE CONTRACTOR SHALL WORK OVER LAWN AREAS THAT HAVE REMAINED PARTIALLY INTACT, TOP DRESSING WITH SOIL. SCARIFYING, AND SEEDING TO FORM A SMOOTH, FULL, EVEN LAWN, FREE OF BARE SPOTS, INDENTATIONS, AND WEEDS.
7.
10. LAWN SEED MIX MIX A: SEEDING RATE: 6 LBS./1,000 SQ.FT LOW MAINTENANCE FESCUE LAWN PREFERRED SEED : LOW MAINTENANCE GRASS SEED MIX 0R APPROVED EQUAL 25% FIREFLY HARD FESCUE 25% BIG HORN GT HARD/SHEEP 20% INTRIGUE CHEWINGS FESCUE 20% QUATRO SHEEP FESCUE 10% MINOTAUR HARD FESCUE
10. ALL GRADING AND UTILITY WORK SHALL BE COMPLETED PRIOR TO INSTALLATION OF PLANT MATERIAL AND LANDSCAPE MULCH.
· WATER MAIN(S) SHALL BE 8 INCH DUCTILE IRON CEMENT-LINED CLASS 51.
· SOIL TEST. THE CONTRACTOR SHALL PROVIDE A SOIL TEST EVALUATION TO DETERMINE THE NEED FOR POLYETHYLENE
INFILTRATION AND EXFILTRATION FOR SANITARY SEWERS SHALL BE LIMITED TO 100 GALLONS PER MILE PER INCH DIAMETER OF PIPE PER 24 HOURS. IF AN AIR TEST IS USED, THE TEST AS A MINIMUM SHALL CONFORM TO THE PROCEDURE DESCRIBED IN ASTM C-828-80, ENTITLED STANDARD PRACTICE FOR LOW PRESSURE AIR TEST OF VITRIFIED CLAY PIPELINES; SANITARY MANHOLES SHALL BE TESTED FOR EXFILTRATION.
LANDSCAPING NOTES:
ENCASEMENT PER ANSI/AWWS CL 05/AZ1.5-82 PRIOR TO WATER MAIN INSTALLATION. SOIL TESTING SHALL BE CONDUCTED BY AN APPROVED SOIL TESTING LABORATORY IN ACCORDANCE WITH WATER AUTHORITY STANDARDS.
· PRESSURE TEST. WATER MAINS TO BE PRESSURE TESTED IN ACCORDANCE WITH THE LATEST WATER AUTHORITY SPECIFICATIONS. A WATER AUTHORITY REPRESENTATIVE MUST WITNESS THIS TEST. C-651, BY USING THE CONTINUOUS FEED METHOD. AFTER FLUSHING AND DISINFECTING THE WATER MAIN, WATER SAMPLES SHALL BE COLLECTED FROM THE MAIN BY THE MONROE COUNTY HEALTH DEPARTMENT. FIRE HYDRANTS ARE NOT ACCEPTABLE SAMPLING POINTS. APPROVAL AND NOTIFICATION BY THE HEALTH DEPARTMENT MUST BE RECEIVED BEFORE THE MAIN IS PLACED IN SERVICE.
· WATER MAINS AND ALL WATER SERVICE LINES SHALL HAVE A MINIMUM OF FIVE FEET OF COVER FROM FINISHED GRADE IN LAWN AREAS AND A MINIMUM OF SIX FEET OF COVER FROM FINISHED GRADE IN PAVED AREAS.
· MINIMUM VERTICAL SEPARATION BETWEEN WATER MAIN AND SEWER MAINS SHALL BE 18" MEASURED FROM THE OUTSIDE OF THE PIPES AT THE POINT OF CROSSING. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER MAINS AND SEWER MAINS SHALL BE TEN FEET MEASURED FROM THE OUTSIDE OF THE PIPES. ONE FULL LENGTH OF WATER MAIN SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. WHERE A WATER MAIN CROSSES UNDER A SEWER, ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECTED FILL) SHALL BE PROVIDED FOR THE SEWERS TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING ON AND BREAKING THE WATER MAINS.
· FIRE HYDRANT WEEP HOLES (DRAINS) SHALL BE PLUGGED WHEN GROUND WATER IS ENCOUNTERED WITHIN SEVEN FEET OF THE FINISHED GRADE.
SEEDING RATE: 4LBS./1,000 SQ.FT OCCASIONAL WET - WET LOCATIONS: 20% RED TOP 20% VIRGINIA WILD RYEGRASS 20% ALKALI GRASS 20% FOX SEDGE 10% AUTUMN BENTGRASS 10% FOWL BLUEGRASS 11. DRY APPLICATION MULCH A. STRAW MULCH SHOULD BE APPLIED TO NEWLY SEEDED AREAS WITHIN 12 HOURS IF HYDRO MULCH IS NOT UTILIZED. B. DRY APPLICATION, STRAW: STALKS OF OATS, WHEAT, RYE OR OTHER APPROVED CROPS WHICH ARE FREE OF NOXIOUS WEEDS. WEIGHT SHALL BE BASED ON A 15 PERCENT MOISTURE CONTENT. C. DRY APPLICATION: WITHIN ONE DAY AFTER SEEDING, COVER THE SEEDED AREAS WITH A UNIFORM BLANKET OF STRAW MULCH AT THE RATE OF 100 POUNDS PER 1000 SQ FT OF SEEDED AREA. 12. HYDRO APPLICATION: APPLY APPROVED MULCH IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDED RATES OF APPLICATION. APPLY SEEDING MATERIALS WITH AN APPROVED HYDRO SEEDER. A.COLORED WOOD CELLULOSE FIBER PRODUCT SPECIFICALLY DESIGNED FOR USE AS A HYDRO-MECHANICAL APPLIED MULCH. ACCEPTABLE PRODUCT: CONWED HYDRO MULCH, CONWED FIBERS, 231 4TH STREET SW, HICKORY, NC 13. FILL TANK WITH WATER AND AGITATE WHILE ADDING SEEDING MATERIALS. USE SUFFICIENT FERTILIZER, MULCH, AND SEED TO OBTAIN THE SPECIFIED APPLICATION RATE. ADD SEED TO THE TANK AFTER THE FERTILIZER AND MULCH HAVE BEEN ADDED. MAINTAIN CONSTANT AGITATION TO KEEP CONTENTS IN HOMOGENEOUS SUSPENSION. PROLONGED DELAYS IN APPLICATION OR AGITATION THAT MAY BE INJURIOUS TO THE SEED WILL BE THE BASIS OF REJECTION OF MATERIAL REMAINING IN TANK.
· ALL MECHANICAL JOINT FITTINGS (TEES, BENDS, PLUGS, ETC.) SHALL BE BACKED WITH 2500 PSI CONCRETE THRUST BLOCKS
14. DISTRIBUTE UNIFORMLY A SLURRY MIXTURE OF WATER, SEED, FERTILIZER, AND MULCH AT A MINIMUM RATE OF 57 GALLONS PER 1000 SQ FT (2500 GALLONS PER ACRE). THE OWNER AND PROJECT REPRESENTATIVE MAY ORDER THE AMOUNT OF WATER INCREASED IF DISTRIBUTION OF SEEDING MATERIALS IS NOT UNIFORM.
11. THE FINAL LOCATION OF TREES AND OTHER LANDSCAPING SHALL BE DETERMINED IN THE FIELD BASED ON UTILITY STAKEOUT AND SHALL NOT CONFLICT WITH TRAFFIC SIGNS AND/OR UTILITIES. STAKE OUT SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO BEGINNING WORK.
SITE 12. ANY CONCERNS RELATED TO SITE CONDITIONS AND/OR PLANT LOCATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.
WILLOW
PO
INT
Y
WA
GE DRID WIN DR.
13. PLANTING BACKFILL MIXTURE: 4 PARTS TOPSOIL (ON-SITE OR IMPORTED), 1 PART PEAT MOSS, 1/2 PART WELL ROTTED MANURE AND 10 LBS. 5-0-5 PLANTING FERTILIZER, MIXED THOROUGHLY PER CUBIC YARD.
TOWN OF WEBSTER 14. MULCH ALL PLANT BEDS, AND INDIVIDUAL TREES IN LAWN AREAS WITH SHREDDED HARDWOOD BARK MULCH TO A DEPTH OF THREE (3") INCHES UNLESS OTHERWISE SPECIFIED ON PLANTING DETAILS, OR AS DIRECTED BY THE LANDSCAPE ARCHITECT DUE TO SITE CONDITIONS.
LOCATION SKETCH N.T.S. STAMP:
15. ANY PLANT WHICH TURNS BROWN, DEFOLIATES OR DIES PRIOR TO FINAL ACCEPTANCE BY THE OWNER, OR DESIGN LANDSCAPE ARCHITECT, SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPLACED WITH THE SAME PLANT (SPECIES, VARIETY AND SIZE) AS SPECIFIED ON THE PLANT SCHEDULE (LIST). 16. THE CONTRACTOR SHALL MAINTAIN ALL PLANT MATERIALS AND LAWN AREAS UNTIL THE PROJECT HAS RECEIVED FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE. MAINTENANCE SHALL INCLUDE, BUT NOT BE LIMITED TO: WATERING, MULCHING, FERTILIZING, SPRAYING (FUNGICIDE, PESTICIDE, ANTI-DESICANT), AS WELL AS RAISING PLANTS THAT HAVE SETTLED TOO DEEP OR REQUIRE STRAIGHTENING.
17. UPON COMPLETION AND ACCEPTANCE OF THE LANDSCAPING, THE LANDSCAPE MATERIALS SHALL BE GUARANTEED FOR TWO (2) YEARS. THE GUARANTEE SHALL BE INCLUSIVE OF ALL MATERIAL AND LABOR COSTS. AT THE END OF THE GUARANTEE PERIOD THE OWNERS REPRESENTATIVE WILL INSPECT ALL PLANT MATERIALS. THE CONTRACTOR SHALL PROMPTLY MAKE ALL REQUIRED REPLACEMENTS WITH PLANT MATERIALS MEETING THE SPECIFICATIONS (E.G. SPECIES, SIZE AND CHARACTER).
18. ALL AREAS DISTURBED BY SITE GRADING AND/OR UTILITY INSTALLATION SHALL RECEIVE APPROVED TOPSOIL (BASED ON APPROVED SAMPLES SUBMITTED BY THE CONTRACTOR) AND SPREAD TO A DEPTH NOT LESS THAN SIX (6")INCHES AFTER COMPACTION. TOPSOIL PLACED FOR LAWNS SHALL BE FINE GRADED, SEEDED, MULCHED AND WATERED UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED. THIS IS EXCLUDING FOUNDATION PLANT BEDS, AND ENTRANCE AREAS. 19. LOCATIONS OF EXISTING BURIED UTILITIES SHOWN ON THE SITE PLAN ARE BASED UPON THE BEST AVAILABLE INFORMATION AND ARE TO BE CONSIDERED APPROXIMATE. THE CONTRACTOR IS RESPONSIBLE TO CALL FOR A UTILITY STAKEOUT PRIOR TO COMMENCING PLANT INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY AND ALL DAMAGE TO UTILITIES, STRUCTURES, AND SITE APPURTENANCES WHICH OCCURS AS A RESULT OF LANDSCAPE INSTALLATION OPERATIONS.
20. EXISTING TREES INDICATED TO BE REMOVED SHALL OCCUR UNDER THE SITE CONTRACT FOR THIS PROJECT. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR NEW PLANTINGS OR RESTORATION OF THE DISTURBED AREA (LAWNS, PLANT BEDS, ISLANDS).
21. PRE-EMERGENT HERBICIDE SHALL BE USED UNDER MULCH IN ALL TREE AND PLANT BED AREAS.
TEMPORARY CONSTRUCTION AREA SEEDING NOTES:
MC EWEN DR.
D OA
4.
PVC SDR-35 6" MIN. SIZE & SHALL BE LAID AT A MINIMUM GRADE OF 1/4" PER FT. STORM SEWER MATERIAL: ADS HDPE 12" MIN.
EROSION AND SEDIMENT CONTROL NOTES:
TOPSOIL AND SEEDING NOTES:
YR BA
3.
STORM SEWERS AND APPURTENANCES SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE LATEST REGULATIONS OF THE MUNICIPALITY
STANDARD WATER MAIN EXTENSION NOTES:
MARITIME DR.
UTILITY CONTRACTOR COORDINATION NOTES:
22. ALL SHRUB BEDS ADJACENT TO LAWN AREAS SHALL HAVE A SPADED EDGE BORDER, UNLESS METAL EDGE, CONCRETE, OR OTHER BORDER IS SPECIFIED.
CLIENT:
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
Passero Associates 242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
(585) 325-1000 FAX: (585) 325-1691
PROJECT MANAGER PROJECT ENGINEER DESIGNER
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
NO. DATE BY
DESCRIPTION
1 2 3
1.
THE AREA MUST BE ROUGH GRADED AND SLOPES PHYSICALLY STABLE.
2.
SEEDING MUST TAKE PLACE WITHIN 24 HOURS OF DISTURBANCE OR SCARIFICATION OF THE SOIL WILL BE NEEDED PRIOR TO SEEDING. TYPICALLY FERTILIZER OR LIME IS NOT USED FOR TEMPORARY SEEDINGS. ANY SEEDING METHOD MAY BE USED THAT PROVIDES UNIFORM APPLICATION OF SEED TO THE AREA. SEEDING
4
3. 4. 5.
PLANTING SEASON
SPECIES
RATE IN LBS./ACRE
SPRING, SUMMER, OR EARLY FALL
RYEGRASS (ANNUAL OR PERENNIAL)
30
LATE FALL OR EARLY WINTER
WINTER RYE (CEREAL RYE)
100
5 6 7 8 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
NOTES
*MULCH THE AREA WITH HAY OR STRAW AT 2 TONS/ACRE. WOOD FIBER HYDROMULCH OR OTHER SPRAYABLE PRODUCTS APPROVED FOR EROSION CONTROL MAY BE USED IF APPLIED ACCORDING TO SPECIFICATIONS.
COMPACTION NOTES 1. THE CONTRACTOR SHALL STRIP THE TOPSOIL AND REMOVE ANY UNSUITABLE SOILS WITHIN THE PROPOSED GRADING LIMITS PRIOR TO PLACEMENT OF FILL MATERIAL. 2. ALL FILL AREAS SHALL BE COMPACTED TO A MINIMUM OF 95% OF MAXIMUM DENSITY OF STANDARD PROCTOR TEST AT OPTIMUM MOISTURE CONTENT.
WATERVIEW PHASE III WEBSTER, NY
3. THE COMPACTION TESTS WILL BE CONDUCTED BY A LICENSED TESTING LABORATORY AND RESULTS SUBMITTED TO DESIGN ENGINEER.
TOWN/CITY: WEBSTER COUNTY: MONROE
NY
PROJECT NO.:
20243903.0002 DRAWING NO.:
C 201 DATE:
OCTOBER 2024
50%-60% OF BASE DIAMETER
2'-
SIDEWALK
2-6" LIFTS OF #2 CRUSHER RUN COMPACTED PROVIDE GEOTEXTILE AS REQUIRED OR AS DIRECTED BY ENGINEER
1.625"-2.41" C TO C
N.T.S.
EDGE OF RAMP
3"
1. QUANTITY OF TRUNCATED DOMES SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY, TO DEPICT REQUIRED SQUARE GRID PATTERN. 2. TRUNCATED DOMES ARE TO BE ALIGNED IN SQUARE GRID PATTERN IN PREDOMINANT DIRECTION OF TRAVEL.
2"-4"
0.625"
1"
6"
10"
6"MIN.
1" 3"
FILL JOINTS WITH UNILOCK POLYMERIC JOINT SAND OR APPROVED EQUIVALENT
TYPICAL WARNING UNIT FOUNDATION COURSE NYSDOT ITEM No. 304-1 TYPE 4 SUBBASE MATERIAL
4"
MULCH CANNOT BE MORE THAN 1 " THICK AT ROOT COLLAR EXTENDING AT LEAST 6" FROM THE BARK, THEN IT CAN BE THICKENED
CONCRETE
1. EXPANSION JOINTS AND FORMED CONTRACTION JOINTS ARE TO BE EDGED WITH CONCRETE FINISHING TOOLS.
ONLY 1" OF MULCH WILL BE PERMITTED AROUND TRUNK
FINISHED GRADE
TOPSOIL MIXTURE UNDISTURBED EARTH
FINISHED GRADE
60°
ROOT BALL
ROOT BALL
AS PER ANLA STD. GOOD SOIL TYPICAL PLANTING
FLAGGING
WEED BARRIER 3" MULCH PLACED AT LEAST 3" TO 6" AWAY FROM THE TRUNK
SUMP MADE OF CORRUGATED PLASTIC TUBING FILLED WITH GRAVEL MAY BE REQUIRED IN HIGH WATER TABLE AREAS
AS PER ANLA STD. POORLY DRAINED CLAYEY SOILS
SHRUB PLANTING DETAIL N.T.S.
ROOT BALL
2"x4"x48" WOOD STAKES-NOTCHED
OPTION FOR AREAS WITH GOOD DRAINAGE
1" MINIMUM COARSE SAND BEDDING MATERIAL 2" DIAMETER WEEP HOLE AT LOW POINT 5. ENTIRE DETECTABLE WARNING SYSTEM FILL WITH COARSE FIELD INCLUDING TRUNCATED DOMES, SAND BEDDING MATERIAL IS TO BE DARK GRAY IN COLOR, PER MUNSELL BOOK NOTATION 10BG 3/1, FEDERAL STANDARD 595B NUMBER 36081, OR APPROVED EQUIVALENT. 6" SUBBASE COURSE
SIDEWALK
7"
#1 AND #2 CRUSHED STONE WEEP WITH 4" PERFORATED PVC WEEP PIPE ENCASED IN WEEP STONE
REMOVE 13 OF BURLAP OR COVERING PRIOR TO BACKFILLING
ROOT COLLAR TO BE SLIGHTLY ABOVE SURROUNDING GRADE
4. DETECTABLE WARNING SYSTEM FIELD IS TO BE LOCATED SUCH THAT OUTER EDGE OF WARNING FIELD NEAREST TO STREET IS 2 TO 4 INCHES OFF BACK EDGE OF CURB.
WEED BARRIER
2 STRANDS NO.12 GALV. GUY WIRE. PROVIDE (3) PER TREE EQUALLY SPACED WITH TURNBUCKLES (1/2"x6")
2"x2" STAKE (THREE WAY) USE 8' STAKES DRIVE 48" BELOW GROUND
3. DETECTABLE WARNING SYSTEM FIELD IS TO BE 2 FEET DEEP, AND IS TO EXTEND ACROSS FULL WIDTH OF SIDEWALK ACCESS RAMP, BUT NOT UP SIDE FLARES.
DOME SPACING
4000 P.S.I. CONCRETE
12"
BACK EDGE OF CURB
0.625"
3" MULCH
4 PARTS TOPSOIL 1 PART ALL-GRO COMPOST MIX
FOR ALL TREES SMALLER 4" CAL AND EVERGREENS 5'-12' HT. REMOVE STAKE ONE YEAR AFTER PLANTING.
STONE STRONG 24 S.F. RETAINING WALL TOP UNIT
3 4" SQUARE PICKET. 16 GAUGE WALL THICKNESS.
UNDISTURBED SOIL
3" SQUARE POST. 14 GAUGE WALL THICKNESS.
4' TALL BLACK ALUMINUM DECORATIVE FENCE ALONG RETAINING WALL
STONE STRONG 24 S.F. RETAINING WALL UNIT
TREE PLANTING DETAIL 8'-0"
N.T.S.
SECTION N.T.S.
MC EWEN DR.
PLANTING BED
EDGE TRENCH
SITE
3. EXPANSION JOINTS TO BE AT 100' INTERVALS AND SHALL BE FORMED WITH 3/4" WIDE PREMOLDED BITUMINOUS JOINT FILLER. THE FILLER MATERIAL SHALL BE CUT TO CONFORM TO THE CROSS SECTION OF THE GUTTER.
3" (TYP.)
60°
AUTOMATIC SET BACK (4" PER UNIT)
WILLOW
R
N.T.S. 5' TYPICAL REFER TO SITE PLAN
6" STEP @ EDGE OF SIDEWALK
UNDISTURBED EARTH
SIGN PANEL
PLANTING BED EDGE TRENCH
CROSS-SLOPE NOT TO EXCEED 1/4" PER FOOT
6" LIFT OF #1 & #2 SCREENED GRAVEL OR CRUSHED LIMESTONE 25' TO NEXT EXPANSION JOINT 5'-0" 5'-0"
NYP1-2
3.715" TYPICAL
N.T.S.
MODIFIED INTERNATIONAL SYMBOL OF ACCESS
TOWN OF WEBSTER
LOCATION SKETCH N.T.S.
DRAIN TILE WALL BASE (SEE DETAIL)
24 S.F. GRAVITY WALL CROSS SECTION W/ MASS EXTENDER
1. FENCE TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS.
N.T.S.
DECORATIVE FENCE
2"x2" SQ. UNISTRUT POST LENGTH VARIES (GALVANIZED STEEL)
SAW CUT EXISTING WALK TO REMAIN
Y
WA
STAMP:
2' MIN. TO CURB
INT
PER MANUFACTURER
5'-6" MIN.
REMOVE, REPLACE AND RESTORE UNSTABLE SUBGRADE AS ORDERED BY ENGINEER
FACE OF CURB
NYP1-2
5" THICK CLASS K CONCRETE TYPICAL 7" THICK THROUGH DRIVEWAYS 3500 PSI MINIMUM
WEED BARRIER
9"
STONE STRONG MASS EXTENDER (USE ON WALLS 7.5' AND TALLER)
9" MIN.
CONCRETE GUTTER DETAIL
PO
GE DRID WIN DR.
4"
30°
D OA
DETECTABLE WARNING SURFACE DETAIL
2. CONTRACTION JOINTS TO BE AT 10' INTERVALS AND SHALL BE FORMED OR SAW CUT TO A DEPTH OF 1/2" BELOW THE SURFACE OF THE GUTTER.
YR BA
UNIT FILL GRASS
4'-0"
1'-8"
2 STRANDS NO.12 GALV. PLIABLE STEEL WIRE (TWIST TO TIGHTEN NOT OVER TIGHTEN, ALLOW FOR SOME SWAY)
NOTES:
ASPHALT PAVEMENT SECTION
10"
GARDEN HOSE
ISOMETRIC
DOME SECTION 1.625"-2.41" C TO C
2'-6"
FOR ALL TREES LARGER 4" CAL. AND EVERGREENS LARGER THAN 12'
0.90"-1.41"
COMPACTED EXISTING SUBGRADE (TOPSOIL REMOVED)
CORNER TO BE EDGED.
SET TRUNK PLUMB LEAN SLIGHTLY INTO PREVAILING WIND
0"
AS PER ANLA STD.
0.20"
6" STEP @ EDGE OF PAVEMENT FOR EACH COURSE
SEE GRADING PLAN
SPACING PER PLAN
MARITIME DR.
121" TYPE 7 TOP COURSE (COMPACTED) 221" TYPE 3 DENSE BINDER COURSE (COMPACTED)
N.T.S.
CURB/WALL - OPTIONAL AT BACK EDGE OF RAMP
SIDEWALK
OP L AS T
NY L
SIDEWALK
A
(SIGN IN LANDSCAPE AREA OR SIDEWALK)
12
TRANSITION CURB
6"
R S R
I RO
1
5' HEADER CURB
TOP OF PAVEMENT
TRANSITION CURB
1.25
Ø 11.64
VIEW A-A 1'-8"
BIT. PAVEMENT SEE PAVEMENT SECTION
242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
(585) 325-1000 FAX: (585) 325-1691
PROJECT MANAGER PROJECT ENGINEER DESIGNER
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
NO. DATE BY
DESCRIPTION
1 2 3 4 5
1. 1:12 IS MAXIMUM SLOPE OF ACCESS RAMP AND SIDE FLARES.
6 7
2. SURFACE OF ACCESS RAMP IS TO BE STABLE, FIRM AND SLIP-RESISTANT. TEXTURE SURFACE WITH COARSE BROOM RUNNING TRANSVERSE TO SLOPE OF ACCESS RAMP.
9' - 0"
6" MIN.
FOUND. COURSE ITEM 609.04 07
1. ALL DIMENSIONS IN INCHES UNLESS NOTED OTHERWISE 2. GRATE HAS LIGHT DUTY RATING 3. QUALITY: MATERIALS SHALL CONFORM TO ASTM A536 GRADE 70-50-05 4. PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT 5. SIZE OF OPENING MEETS REQUIREMENTS OF AMERICAN DISABILITY ACT AS STATED IN FEDERAL REGISTER PART III, DEPARTMENT OF JUSTICE, 28 CFR PART 36.
NOTES:
f'c= 4000 psi
6"
(TYP.)
N
TOP OF CURB
TOPSOIL
1"
SEE BLOWUP FOR STRIPING DIMENSIONS
20' - 0" (TYP.)
LE
Passero Associates
12 1
N.T.S.
20" SPACE (TYP.)
CT I
9" 2"
4" WIDE PAINTED WHITE STRIPE
DU
CURB/WALL - OPTIONAL AT BACK EDGE OF RAMP
N.T.S.
CONCRETE SIDEWALK
4" WIDE WHITE PAINTED STRIPE
Ø14.95
ACCESS RAMP TYPE C ISOMETRIC
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
D
TYPICAL POST MOUNT HANDICAP SIGN INSTALLATION
CLIENT:
IN
3'-0"
3" COVER
CONSTRUCTION JOINT
T O WA T E
B
E
Jacob Lewis
ACCESSIBLE R7-8P
12" DIA.
1) THE GRAVEL OR STONE BASE SHALL BE PLACED ON A WELL GRADED AND COMPACTED SUBGRADE. THE GRAVEL OR STONE BASE SHALL BE THOROUGHLY COMPACTED. 2) ALL EXPOSED SURFACES SHALL BE BROOMED AND EDGES FINISHED WITH A 1.4" RADIUS EDGING TOOL. THE FINISHED CONCRETE SURFACE SHALL BE TREATED WITH A CLEAR, NON-YELLOWING CURING COMPOUND. 3) CONCRETE SHALL BE PLACED USING COLD WEATHER CONCRETE PROCEDURES IN ACCORDANCE WITH ACI 306 WHEN THE AMBIENT AIR SURFACE TEMPERATURE IS BELOW 40 DEGREES. 4) ALL WORK SHALL MEET THESE SPECIFICATIONS. 5) ALL WORK SHALL CONFORM TO ADA REQUIREMENTS.
10/29/2024 11:10 AM
VAN
CONCRETE BASE
UT
8 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
SIDEWALK ACCESS RAMP N.T.S.
45°
DETAILS
MOUNTABLE CONCRETE CURB DETAIL
CURB LINE
N.T.S.
1/2" PREMOLDED BITUMINOUS-IMPREGNATED FELT FULL DEPTH OF CONCRETE CURB
TYPICAL PARKING PAVEMENT MARKING LAYOUT
EXIST. SLOPE
EDGE OF PAVEMENT
N.T.S.
SHEAR STEP SAW CUT 2' WIDE x 1 1/2" DEEP TACK COAT ALL VERT. & HORIZ. SURFACES PRIOR TO TOP COAT. CAP ALL NEW SEAMS WITH JOINT SEALER
6"
1"
4"
C ROAD
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 DETAILS.DWG
A
3 1/2" I.D. PIPE SLEEVE
POL L
SAW CUT SIDEWALK AT JOINT NEAREST CONSTRUCTION LIMITS
NOT
CONTRACTION JOINT
SAW CUT, OR WET CUT CONCRETE WITH TROWEL OR JOINT TOOL 2" MINIMUM DEPTH FULL WIDTH OF CONCRETE SLAB.
DO
EXPANSION JOINT
1/2" PREMOLDED BITUMINOUSIMPREGNATED FELT FULL WIDTH AND DEPTH OF CONCRETE SLAB.
R7-8
A
SIDE VIEW
Y WA
S
B
2'-0"
CONCRETE OR GRANITE CURB PER DETAIL
MATCH TRANSITION CURB TO ADJACENT CURB AND FINISHED GRADE FINISH GRADE PER PLANS
1. PROVIDE 5/8" MAX. LIP FOR HEADER CURB AT SIDEWALK RAMPS. 2. TRANSITION CURB LENGTHS SHALL BE FROM 18" TO 36" AS DETERMINED BY THE PROJECT MANAGER UNLESS OTHERWISE INDICATED IN THE DRAWINGS. MATCH TRANSITION CURB TO ADJACENT CURB OR HEADER CURB/PAVEMENT.
CONC. CURB/ GRANITE CURB
6" SAW CUT FULL DEPTH (15" MIN.)
BIT. PAVEMENT SEE PAVEMENT SECTION
6" R=1 1/2"
9" CRUSHED STONE MEETING NYSDOT ITEM 304.12 PAVEMENT
BACKFILL MATERIAL BELOW AND TO SIDES OF STRUCTURE SHALL BE NATIVE SOIL AND BE PLACED UNIFORMLY IN 12" LIFTS AND COMPACTED TO A MIN OF 90%
NYSDOT ITEM NO 1'-8" 609.04 CLASS 'A' CONCRETE 6"
WATERVIEW PHASE III WEBSTER, NY
6"
2.75'
6"
MONROE
NY
PROJECT NO.:
16"
6" PERFORATED CORRUGATED POLYETHYLENE UNDERDRAIN PIPE AND FILTER MATERIAL
PAVEMENT SECTION 15"
(FOR CONNECTION TO EXISTING PAVEMENT) N.T.S.
NYLOPLAST DROP IN GRATES FIT INSIDE ADS N-12, HANCOR DUAL WALL, SDR 35 SEWER, & IPS SCH 40 DWV PIPE
TOWN/CITY: WEBSTER
REFER TO ENTRANCE PROFILE (RIGHT) FOR SLOPE
PAVEMENT KEY DETAIL
1/8" PITCH TOWARD ROADWAY
36" NOTE: 1. TRANSITION CURB LENGTHS SHALL BE 36" UNLESS OTHERWISE INDICATED IN THE DRAWINGS.
TRANSITION CURB TO GRADE N.T.S.
20243903.0002 DRAWING NO.:
18" - 36" ( SEE NOTES )
TRANSITION CURB DETAIL N.T.S.
C 202
18"
CONCRETE CURB DETAIL N.T.S.
DATE:
NYLOPLAST DRAIN AND GRATE N.T.S.
OCTOBER 2024
RETICULINE TYPE NO. 9 CAST IRON FRAME AND COVER. COVER TO BE VENTED AND HAVE "STORM" CAST INTO TOP. ALL TOP SLABS & CASTING SHALL BE HS-20 LOADING CAPABLE FINISHED GRADE
2"X4" WOOD FRAME
PLAN VIEW
20"MIN.
FLOW
1
18"
FILTER FABRIC
1
1' MIN.
COMPACTED SOIL
6"
CONSTRUCTION SPECIFICATIONS CONSTRUCTION SPECIFICATIONS
2. FILTER CLOTH TO BE TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION. FENCE SHALL BE WOVEN WIRE, 12 1/2 GAUGE, 6" MAXIMUM MESH OPENING. 3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY SIX INCHES AND FOLDED. FILTER CLOTH SHALL BE EITHER FILTER X, MIRAFI 100X, STABILINKA T140N, OR APPROVED EQUIVALENT. 4. PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT. 5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE.
N.T.S.
FL
N.T.S.
OW
FLO
FILTER FABRIC DROP INLET PROTECTION
STABILIZED CONSTRUCTION ACCESS
N.T.S.
N.T.S.
W
N.T.S.
WEAKENED PLANE JOINT (TYP. EACH CORNER)
MC EWEN DR.
LIMIT OF TRENCH EXCAVATION A
SWALE B 1' 6'
AS REQUIRED
OUTLET AS REQUIRED SEE ITEM 8 BELOW.
1' MIN.
1:1 OR FLATTER
PLAN VIEW
1:1 OR FLATTER
6. 7. 8.
TYPE OF TREATMENT 1 2 3 4
CHANNEL GRADE 0.5-3.0% 3.1-5.0% 5.1-8.0% 8.1-20.%
A(5 AC. OR LESS) SEED AND STRAW MULCH SEED AND STRAW MULCH SEED WITH JUTE OR EXCELSIOR, SOD LINED WITH 4-8" RIP-RAP
CROSS SECTION
1.
2. 3. 4. 5.
TEMPORARY SWALE DETAIL
24"x24" OR 36"x36"
6"
# 4 BARS 12" OC BOTH WAYS
UNDISTURBED EARTH
CONCRETE ENCASEMENT
O.D.
6.
SEDIMENT SHALL BE REMOVED AND THE TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO 1/2 THE DESIGN DEPTH OF THE TRAP. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE. THE VOLUME OF SEDIMENT STORAGE SHALL BE 1800 CUBIC FEET PER ACRE OF CONTRIBUTORY DRAINAGE. THE STRUCTURE SHALL BE INSPECTED AFTER EACH RAIN AND REPAIRS MADE AS NEEDED. CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION AND WATER POLLUTION SHALL BE MINIMIZED. THE SEDIMENT TRAP SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE CONSTRUCTED DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. ALL CUT SLOPES SHALL BE 1:1 OR FLATTER.
SEE PLAN FOR ELEV
SAND MEDIA
1.5'
9"
OVER 36"
1.5'
12"
SEE PLAN
PROPOSED HDPE PIPE (SEE PLAN)
Y
WA
18"x26" PRECAST CONCRETE CATCH BASIN SEE NOTE 4
TOWN OF WEBSTER
LOCATION SKETCH
ONE OR TWO COURSES COMMON BRICK WITH MORTAR
2"
N.T.S.
DING
3" TOPSOIL AND BED
SEE NOTE 2
6" PERF. PIPE ENTIRE LENGTH OF GUTTER #1 CRUSHED STONE BACKFILL
FLOW
SEE NOTE 3
FILL SUMP WITH CONCRETE
COMPACTED SELECT FILL 1/2O.D.
SPECIAL BEDDING IN UNSTABLE MATERIAL
FIRST CLASS CLASS "B"
21" TO 36"
5'
PROPOSED HDPE PIPE SEE PLAN FOR ELEV
CAST IN PLACE
INT
A
B
UNDISTURBED EARTH
ROCK
N.T.S.
INVERT SEE PLAN FOR ELEV
6" UNDERDRAIN
O.D.
B
CATCH BASIN SEDIMENT TRAP
A
6" UNDERDRAIN
STONE BEDDING
PIPE DIA. DIM. A DIM. B
24" X 24" CATCH BASIN
OR EQUIVALENT 3500 P.S.I.
PROPOSED 4" PVC UNDERDRAIN IN PAVEMENT AREAS COATED WITH 2 COATS OF BITUMINOUS TAR
1/4"/FT
COMPACTED SELECT FILL STONE BEDDING
1.0'
24" X 24" CATCHBASIN
CAST IRON FRAME AND GRATE, NEENAH R 3359,
PO
GE DRID WIN DR.
A
UP TO 18"
24"x24" GRATE SEE PLAN FOR ELEV
WILLOW 4'-2"
FLOW
12"
3 ACRES
Jacob Lewis
ROCK
12"MIN.
N.T.S.
10/29/2024 11:10 AM
A
CONSTRUCTION SPECIFICATIONS
9. PERIODIC INSPECTION AND REQUIRED MAINTENANCE MUST BE PROVIDED AFTER EACH RAIN EVENT.
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 DETAILS.DWG
B
A
B(5 AC -10AC) SEED AND STRAW MULCH SEED USING JUTE OR EXCELSIOR LINED WITH 4-8" RIP-RAP OR RECYCLED CONCRETE EQUIVALENT ENGINEERED DESIGN
24"x24" GRATE (SEE PLAN)
FINISH GRADE
LIMIT OF TRENCH EXCAVATION
ALL TEMPORARY SWALES SHALL HAVE UNINTERRUPTED POSITIVE GRADE TO AN OUTLET. DIVERTED RUNOFF FROM A DISTURBED AREA SHALL BE CONVEYED TO A SEDIMENT TRAPPING DEVICE. DIVERTED RUNOFF FROM AN UNDISTURBED AREA SHALL OUTLET DIRECTLY INTO AN UNDISTURBED STABILIZED AREA AT NON-EROSIVE VELOCITY. ALL TREES, BRUSH, STUMPS, OBSTRUCTIONS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE REMOVED AND DISPOSED OF SO AS NOT TO INTERFERE WITH THE PROPER FUNCTIONING OF THE SWALE. THE SWALE SHALL BE EXCAVATED OR SHAPED TO LINE, GRADE, AND CROSS SECTION AS REQUIRED TO MEET THE CRITERIA SPECIFIED HEREIN AND BE FREE OF BANK PROJECTIONS OR OTHER IRREGULARITIES WHICH WILL IMPEDE NORMAL FLOW. FILLS SHALL BE COMPACTED BY EARTH MOVING EQUIPMENT. ALL EARTH REMOVED AND NOT NEEDED FOR CONSTRUCTION SHALL BE PLACED SO THAT IT WILL NOT INTERFERE WITH THE FUNCTIONING OF THE SWALE. STABILIZATION SHALL BE AS PER THE FLOW CHANNEL STABILIZATION CHART BELOW:
SITE
6" 6"
2'-2"
CONCRETE GUTTER
1/2 O.D.
5.
ANCHOR BOLT
CONCRETE 3000 PSI
B ROCK CONCRETE (3000 PSI MIN.) UNDISTURBED EARTH CONCRETE CRADLE CLASS "A"
CONSTRUCTION SPECIFICATIONS
4.
B
COMPACTED SELECT FILL
YARD DRAIN
0.5% OR STEEPER DEPENDENT ON TOPOGRAPHY
A
MIN. OR 1/4 O.D.
SWALE A 1' 4'
FL OW
3"
C D
O.D.
12"MIN.
W FLO
SLOPE 2:1 OR FLATTER
CROSS SECTION
1. 2. 3.
A
EXISTING GROUND
D MIN. LEVEL
SLOPE 2:1 OR FLATTER
O.D.
6" GUTTER FLOW LINE
GRATE TO BE NYSDOT RETICULINE TYPE 9. (24"X24") OR TYPE 6 OR EQUAL (36"x36") 24" 24"x24" OR 36" X 36" P.C. CONCRETE INLET BOX 3" 4" PRECAST
30" (MIN)
A
STORAGE AREA C MIN.
#4 BENT BARS, OVERLAP 12", 2" MIN COVER
3/4" FULL DEPTH EXPANSION JOINT
D OA
SILT FENCE DETAIL
STANDARD STORM MANHOLE DETAIL
YR BA
STONE CHECK DAM
MAXIMUM DRAINAGE AREA 1 ACRE
MINIMUM 6" CRUSHED STONE FOR LEVELING PRECAST CONCRETE BASE
UNDISTURBED EARTH OR ROCK
1. STONE SIZE - USE 2" STONE, OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. 2. LENGTH - NOT LESS THAN 50 FEET (EXCEPT ON A SINGLE RESIDENCE LOT WHERE A 30 FOOT MINIMUM LENGTH WOULD APPLY). 3. THICKNESS - NOT LESS THAN SIX (6) INCHES. 4. WIDTH - TWELVE (12) FOOT MINIMUM, BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR EGRESS OCCURS. TWENTY-FOUR (24) FOOT IF SINGLE ENTRANCE TO SITE. 5. FILTER CLOTH - WILL BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE. 6. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 7. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY, ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACTED ONTO PUBLIC RIGHTS-OF-WAY MUST BE REMOVED IMMEDIATELY. 8. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON A AREA STABILIZED WITH STONE AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 9. PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN
CONSTRUCTION SPECIFICATIONS 1. FILTER FABRIC SHALL HAVE AN EOS OF 40-85. BURLAP MAY BE USED FOR SHORT TERM APPLICATIONS. 2. CUT FABRIC FROM A CONTINUOUS ROLL TO ELIMINATE JOINTS. IF JOINTS ARE NEEDED THEY WILL BE OVERLAPPED TO THE NEXT STAKE. 3. STAKE MATERIALS WILL BE STANDARD 2" x 4" WOOD OR EQUIVALENT. METAL WITH A MINIMUM LENGTH OF 3 FEET. 4. SPACE STAKES EVENLY AROUND INLET 3 FEET APART AND DRIVE A MINIMUM 18 INCHES DEEP. SPANS GREATER THAN 3 FEET MAY BE BRIDGED WITH THE USE OF WIRE MESH BEHIND THE FILTER FABRIC FOR SUPPORT. 5. FABRIC SHALL BE EMBEDDED 1 FOOT MINIMUM BELOW GROUND AND BACKFILLED. IT SHALL BE SECURELY FASTENED TO THE STAKES AND FRAME. 6. A 2" x 4" WOOD FRAME SHALL BE COMPLETED AROUND THE CREST OF THE FABRIC FOR OVER FLOW STABILITY.
1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES OR STAPLES. POSTS SHALL BE STEEL EITHER "T" OR "U" TYPE OR HARDWOOD.
1. STONE WILL BE PLACED ON A FILTER FABRIC FOUNDATION TO THE LINES, GRADES AND LOCATIONS SHOWN IN THE PLAN. 2. SET SPACING OF CHECK DAMS TO ASSUME THAT THE ELEVATIONS OF THE CREST OF THE DOWNSTREAM DAM IS AT THE SAME ELEVATION OF THE TOE OF THE UPSTREAM DAM. 3. EXTEND THE STONE A MINIMUM OF 1.5 FEET BEYOND THE DITCH BANKS TO PREVENT CUTTING AROUND THE DAM. 4. PROTECT THE CHANNEL DOWNSTREAM OF THE LOWEST CHECK DAM FROM SCOUR AND EROSION WITH STONE OR LINER AS APPROPRIATE. 5. ENSURE THAT CHANNEL APPURTENANCES SUCH AS CULVERT ENTRANCES BELOW CHECK DAMS ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONE. MAXIMUM DRAINAGE AREA 2 ACRES.
SPRING LINE OF PIPE
GATHER EXCESS AT CORNERS
4" SECTION VIEW
SECTION B-B NOT TO SCALE
9" IN EARTH (MIN.) OR 6" IN ROCK (MIN.)
CONSTRUCTION SPECIFICATIONS
16"MIN.
EMBED FILTER CLOTH A MIN. OF 6" IN GROUND.
BENCH WALLS SLOPE 1/2" PER FT. (TYP.)
11"
1
PRECAST CONCRETE BASE
8"
1
7" MANHOLE JOINTS SHALL CONFORM TO ASTM C443 OR C990
MARITIME DR.
W O
FRAME
UNDISTURBED GROUND
SECTION A-A NOT TO SCALE
12'MIN.
12'MIN.
MORTAR TOP SLAB PLASTIC M & A INDUSTRIES MANHOLE STEPS WITH DROP FRONT DESIGN AND GROOVED THREAD SURFACE. PROVIDE 4" KNOCK OUT FOR WEEP PIPE COAT INSIDE AND OUTSIDE SURFACES WITH TWO COATS OF COAL TAR COATING A.S.T.M. D-450 TYPE B
24" 5" SQUARE OPENING 12" TYP.
1"-6"
24" MAX @ CENTER
BURIED FABRIC
DROP INLET WITH GATE
CONCRETE RISER SECTIONS A.S.T.M. C 478
8"
CL UNDERDRAIN AND GUTTER FLOW LINE
CUTOFF TRENCH DESIGN BOTTOM
B
1
EXISTING GROUND
PERSPECTIVE VIEW
2
1
8" MIN.
36" MIN. FENCE POST WOVEN WIRE FENCE (MIN. 14 1/2 GAUGE W/ MAX. 6" MESH SPACING) WITH FILTER CLOTH
PRECAST SPACERS MAXIMUM THREE COURSES
50'MIN.
FL
H (Ft) X= SLOPE (FT/FT) 2
PROFILE
24" MAX.
MOUNTABLE BERM (OPTIONAL)
1'-8"'
FILTER FABRIC
3' MIN.
FILTER CLOTH
5:1
10"
W
O FL
B 1.5' MIN.
EXISTING GROUND
HEIGHT OF FILTER = 16" MIN.
A PROFILE NOT TO SCALE
9"MIN.
6"MIN.
FILL ALL AROUND WITH CONCRETE EXCEPT IN PAVEMENT & COAT WITH TAR
EXISTING PAVEMENT
CREST 24" MAX @ CENTER
H
FABRIC
EXISTING PAVEMENT
10' MIN.
S LO P E
TOE
3'
36" MIN. LENGTH FENCE POSTS DRIVEN MIN. 16" INTO GROUND.
A
SAME ELEVATION
CUTOFF TRENCH 18" WIDE 6" DEEP
50'MIN.
STAKE
10' MIN.
10' MAX. C. TO C. L L
WOVEN WIRE FENCE (MIN. 14 1/2 GAUGE W/ MAX. 6" MESH SPACING)
1.5' MAX.
SPACING VARIES DEPENDING ON CHANNEL SLOPE X
6"
STONE BEDDING OR COARSE AGGREGATE AS DETERMINED BY DEVELOPER'S ENGINEER
COMPACTED ITEM 605.10 AROUND PIPE AND TO 3" ABOVE TOP OF PIPE, REMAINDER OF THE TRENCH TO BOTTOM OF ROAD BASE TO BE FILLED WITH RUNOF-BANK GRAVEL COMPACTED IN 6" LIFTS
6" 12" N-12 PLASTIC PIPE MIN 1% SLOPE
6" COMPACTED No. 2 STONE IF PRECAST BASE USED
12"
#1 CRUSHED STONE BEDDING
NOTES:
UNDISTURBED EARTH
1. STANDARD SPECIFICATION REFERENCES SECTION 1B-EARTHWORK SECTION 1C-GUTTERS AND SIDEWALKS SECTION 2A-STORM DRAINAGE 2. ALL INTERIOR & EXTERIOR CONCRETE SURFACES TO RECEIVE TWO COATS KOPPERS SUPER SERVICE BLACK, OR EQUIVALENT 3. GROUT ALL SPACES BETWEEN PRECAST INLET AND PIPING (TYP.) 4. PRECAST REINFORCED CONCRETE CATCH BASIN TO HAVE 6" MINIMUM WALLS AND BOTTOM. 5. DETAIL SHOWN IS FOR GUTTER INLET FOR YARD INLET, SEE DETAIL ABOVE
1. ALL CONCRETE TO BE 3500 psi CLASS A N.Y.S.D.O.T. ITEM 601.05 2. ALL CONCRETE IN CONTACT WITH ASPHALT PAVEMENT SHALL BE COVERED WITH A TACK COAT IN ACCORDANCE WITH N.Y.S.D.O.T. SECTION 407.
1. TRENCH BACKFILL SHALL BE AS REQUIRED BY THE HIGHWAY OWNER. 2. SELECT FILL SHALL BE SAND, GRAVEL, AND SIMILAR MATERIAL WHICH SHALL BE FREE FROM CLAY, LOAM, ORGANIC MATERIAL, DEBRIS, FROZEN MATERIAL AND SHALL CONTAIN ONLY SMALL AMOUNTS OF STONE, PEBBLES OR LUMPS OVER ONE INCH IN GREATEST DIMENSION BUT NONE OVER TWO INCHES IN GREATEST DIMENSION. 3. STONE BEDDING SHALL MEAN APPROVED IMPORTED AGGREGATE MEETING THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF TRANSPORTATION, STANDARD SPECIFICATION, JAN 2, 1990 EDITION, AS REVISED, SUBSECTION 703-0201 "CRUSHED STONE". PRIMARY SIZE 1 OR A MIXTURE OF PRIMARY SIZES 1 AND 2 WASHED. 4. COARSE AGGREGATE SHALL MEAN APPROVED IMPORTED AGGREGATE MEETING THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF TRANSPORTATION, STANDARD SPECIFICATION, JAN 2, 1990 EDITION, AS REVISED, SUBSECTION 703-0201 "CRUSHED STONE". PRIMARY SIZE 3 AND/OR 4 5. THIS FIGURE APPLIES TO SANITARY MAINLINE AND LATERAL PIPE INSTALLATION AS WELL AS FORCEMAINS.
12"
STANDARD CATCH BASIN N.T.S.
CLIENT:
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
GUTTER INLET N.T.S.
Passero Associates
STORM SEWER/SANITARY SEWER BEDDING DETAILS N.T.S.
OUTLET
242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
(585) 325-1000 FAX: (585) 325-1691
PROJECT MANAGER PROJECT ENGINEER DESIGNER
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
NO. DATE BY
DESCRIPTION
1 2 SEE PLAN
3 4
PLAN VIEW A
OUTLET CONTROL STRUCTURE
5 6
SECTION VIEW
FRONT VIEW
7
UNDERDRAIN COLLECTION SYSTEM
BERM
8
FILL SUMP WITH 3500 PSI CONCRETE
SAND FILTER CONTROL STRUCTURE
2'
4'
UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
2'
PLAN VIEW
WATER QUALITY SECTION "A-A"
WATER QUALITY
OUTLET STRUCTURE
DETAILS
N.T.S.
RIP-RAP DETAIL
6" TOPSOIL OVER MEMBRANE 1:3 M
INFLOW
AX.
FROM SI
INV SEE PLAN 6" PONDING
CONTROL STRUCTURE SEE DETAIL ABOVE
N.T.S.
CLASS 0 RIP RAP (4" AVE) STONE SURFACE 6" THICK.
3 max
6" PONDING 4" THICK STONE MULCH MEDIUM WASHED RIVER GRAVEL
1:3 max
1
TE
UNDERDRAIN
2.5-4' PLANTING SOIL
36" DEEP 100% CONCRETE SAND WITH PERC RATE >1"/15 MIN
OUTFLOW PIPE
WATERVIEW PHASE III WEBSTER, NY
FILTER FABRIC
6" UNDERDRAIN TO CONNECT TO OVERFLOW C.B. GEOTEXTILE FABRIC. MIRAFI 140N OR APPROVED EQUAL.
PROVIDE PLASTIC WATERPROOF MEMBRANE IN BERM OR STORMWATER MANAGEMENT AREA
SECTION VIEW
6" MINIMUM 12" OF CLEANED WASHED GRAVEL (APPROX. 1.5" TO 2" DIAMETER ROCK)
1. FOR ALL SEEDING & STABILIZATION MEASURES IT IS THE RESPONSIBILITY OF THE OWNER & DEVELOPER TO ENSURE THAT FINAL STABILIZATION OCCURS AS REQUIRED BY THE NYSDEC. 2. SAND SHALL NOT BE PLACED IN BIO RETENTION AREA UNTIL SITE HAS REACHED 50% STABILIZATION. SILT FENCE TO BE PROVIDE AROUND ENTIRE BIO RETENTION AREA AT ALL TIMES.
SAND FILTER (SOIL MEDIA SECTION)
TOWN/CITY: WEBSTER COUNTY: MONROE UNDERDRAIN
PROFILE VIEW
6" PERFORATED PIPE IN 8" GRAVEL JACKET
NY
PROJECT NO.:
20243903.0002 DRAWING NO.:
C 203
SECTION VIEW DATE:
BIORETENTION AREA N.T.S.
OCTOBER 2024
SP 1
SP 1
GRADE
WATERVIEW PHASE III PLANT SCHEDULE 2024.10.14
CA 2 OHD
OHD
OHD
RK 6 RETAINING WALL SP 1
OHD
IG 2
RA 2 OHD
OHD
IG 2
CA 2
CCL 2
OHD
OHD
OHD
OHD
HQ 2
OHD
SP 1
FOUNDATION PLANTING DETAIL B (NO WALL, 1 BUILDING)
ROOT
SPACING / SPREAD
MATURE HEIGHT
REMARKS
HQ 2
D
NATIVE
WATER MAIN
BEND
B
AR
3
Acer rubrum "Franksred"
Red Sunset Maple
2 1/2-3"
B&B
As Shown
GT
6
Gleditsia triacanthos var. "Inermis"
Thornless Shademaster Honey Locust
3 1/2-3"
B&B
As Shown
NS
3
Nyssa sylvatica "Wildfire"
Black Gum
2 1/2-3"
B&B
As Shown
Fall Planting Hazard
35-40'
Fall Planting Hazard
Yes
30-50'
No
30-50'
Yes
8"
8" GEOTEXTILE (AROUND STONE OR SLEEVE AROUND PIPE)
8" PERFORATED UNDERDRAIN
FILTER STONE TYPE 1
AG
2
Amelanchier x grandiflora " Robin Hill Pink"
Robin Hill Serviceberry
8-10'
B&B
15-20'
CC
3
Cercis canadensis "The Rising Sun" - (TF)
The Rising Sun Redbud (Tree Form)
6-7'
B&B
As Shown
CV
6
Chioanthus virginicus
Fringetree
6-7'
B&B
MS
5
Magnolia stellata "Royal Star"
Royal Star Magnolia
7-8'
SV
6
Syringa vulgaris "Agincourt"
Agincourt Lilac
5-6'
20-25'
Yes
Fall Planting Hazard
8-12'
Yes
As Shown
Multi-Stemmed
18-20'
Yes
B&B
As Shown
Heavy
10-15'
No
B&B
As Shown
Multi-Stemmed
8-10'
Yes
Multi-Stemmed
2'-0"
LAWN AREA UNDERDRAIN N.T.S.
CA
2 - 3/4" STEEL REINFORCING RODS
12" MIN & DEPTH VARIES TO DRAIN PAVEMENT SUB-BASE
SHRUBS 14
Clethra alnifolia "Sixteen Candles"
Sixteen Candles Summersweet
2-3'
#3 Cont.
3-5'
3-4'
Yes
CCL
6
Cotinus coggygria "Lilla"
Lilla Dwarf Smoke Bush
2-3'
#3 Cont.
4'
4'
No
HQ
12
Hyrangea quercifolia "Ruby Slippers"
Ruby Slippers Oakleaf Hydrangea
2-3'
#5 Cont.
3-4'
4-5'
No
IG
20
Ilex glabra "Shamrock"
Shamrock Inkberry
2-3'
#5 Cont.
5'
4-5'
Yes
PO
16
Physocarpus opulifolius "Little Joker"
Little Joker warf Ninebark
2-3'
#3 Cont.
3-4'
3-4'
Yes
RA
4
Rhus aromatica "Gro-Low"
Gro-Low Fragrant Sumac
18-24"
#3 Cont.
6-10'
2'-4'
Yes
RK
30
Rosa "Knock-out"
Knockout Rose
18-24"
#3 Cont.
3-4'
3-4'
No
SP
12
Syringa petula 'Miss Kim'
Miss Kim Dwarf Lilac
30-36"
#5 CONT.
3-6'
3-6'
No
(1) male to (4) female
fragrant bloom
4"
4" GEOTEXTILE (AROUND STONE OR SLEEVE AROUND PIPE)
2 - 3/4" STEEL REINFORCING RODS
UNDISTURBED SOIL
4"
UNDISTURBED SOIL
4" PERFORATED UNDERDRAIN PLAN
FILTER STONE TYPE 1
ELEVATION
1'-0" MINIMUM VOLUME OF CONCRETE
BEND
PAVEMENT AREA UNDERDRAIN
1. Existing Trees & Buffer Material to Remain & be Protected During Construction. 2. Native NYS plants are noted. 3. All plants shall be as specifies or approved equal.
OHD
CONCRETE THRUST BLOCK
CONCRETE THRUST BLOCK
N.T.S.
OHD
BEND
DECIDUOUS TREES
FLOWERING AND ORNAMENTAL TREES
OHD
OHD
SIZE
MINIMUM ALLOWABLE DIMENSIONS FOR VERTICAL THRUST BLOCKS (IN FEET)
DIMENSIONS
A
B
C
D
E
0.7 CY 1.1 CY 2.2 CY
3.0 3.5 5.0
1.0 1.0 1.0
1.0 1.5 1.5
2.5 3.0 4.0
0.5 1.0 1.5
6" x 11-1/4° 6" x 22-1/2° 6" x 45°
DHO DHO
Y
WA
HORIZONTAL THRUST BLOCK
TOWN OF WEBSTER
TAPPING SLEEVE & TAPPING VALVE w/MJ RESTRAINT
LOCATION SKETCH N.T.S. STAMP:
WATER MAIN DHO
DHO
6"
DHO
54.7'
CCL 2
INT
PIPE ZONE
IN ROCK, BACKFILL PIPE ZONE WITH SAND
CA 2
PO
GE DRID WIN DR.
5' MIN IN LAWN 6' MIN IN PAVEMENT
BACKFILL WITH SELECT FILL, OR SUITABLE NATIVE SOIL, COMPACT IN A MAXIMUM OF 6" LIFTS
DHO
FOUNDATION PLANTING DETAIL
WILLOW
GRADE
SP 1
D OA
SITE
SP 1
CA 2
MC EWEN DR.
N.T.S.
RK 2
YR BA
VERTICAL THRUST BLOCK
RA 2
MARITIME DR.
OHD
COMMON NAME
E
IG 2
BOTANICAL NAME
C
IG 2
OHD
OHD
HQ 1
HQ 1
QTY
4"
OHD
OHD
FOUNDATION PLANTING DETAIL A (WITH WALL, 4 BUILDINGS) PO 4
KEY
A
RK 2
CL
CCL 2
RK 2
6" MIN IN ROCK 12" MIN IN SOIL TRENCH LIMITS
FOUNDATION PLANTING DETAILS
NOTES:
SPECIAL NOTE:
THE OPENING IN THE RISER AND BASE SECTION SHALL BE CORED AND FILLED WITH EPOXY MORTAR SIKADUR 33 BY SIKA OR FLEXOLITH GEL BY DURAL.
"A"
6"
UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS IN VIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 AND ARTICLE 147 SECTION 7307, THESE PLANS ARE COPYRIGHT PROTECTED. ©
EXISTING INVERT CHANNEL
"A"
GRADE
VERTICAL DROP SHALL BE SAME SIZE AS THE SEWER ENTERING THE MANHOLE (MIN. 8").
VALVE BOX
SANITARY SEWER MANHOLE N.T.S.
A
CONCRETE THRUST BLOCK
12"MIN
SECTION "A-A"
EXTENSION
CONCRETE THRUST BLOCK LENGTH ALONG MAIN IS 2' (MIN)
BEND
WATERVIEW PHASE III WEBSTER, NY
TYPE 1 CRUSHED STONE FOR WIDTH OF TRENCH AROUND VALVE BOX
BASE
(FOR OUTSIDE DROP CONNECTION)
UNDISTURBED SOIL
#1 WASHED STONE FOR VALVE WIDTH OF HYDRANT TRENCH
WATER MAIN
CONCRETE THRUST BLOCK
W PLAN
UNDISTURBED SOIL ELEVATION
SECTIONAL PLAN ROCHESTER PURE WATERS DISTRICT SEWER CONNECTIONS TO EXISTING MANHOLE
SOLID CONCRETE BLOCK (MIN:4"x8"x16")
NOTE:
6"x18" (MIN) ANCHOR PIPE
MJ ANCHOR TEE, 6" OUTLET
JUNE '87 REV: MAR. 2000
DETAILS
C L
VALVE BOX
SOLID CONCRETE BLOCK (MIN:8"x8"x16") 12" MIN. #1 AND #2 CRUSHED STONE (NYSDOT GRADATION TABLE 703-4) LEVELING BASE THOROUGHLY COMPACTED UNDISTURBED EARTH
12"
BEND GRADE
6"
6"
WATER MAIN
N.T.S.
W
BRICK, CLAY PIPE OR HALF PIPE SEWER INVERT (ASTM C-32)
6 8
NEW SEWER TO BE CONNECTED
SHAPE NEW CHANNEL
5
HORIZONTAL THRUST BLOCK FOR TEES AND PLUGS
6" MIN.
UNDISTURBED GROUND
5000 PSI CONCRETE BENCH MANITOU MIX ID 1696
4
ELEVATION
7
FILL WITH EPOXY MORTAR AROUND PIPE.
1/2" PE SLOPE R FT.
FIG. 4
DESCRIPTION
2
NEW SEWER CONNECTED. (SEE FIG. 3 FOR ADDITIONAL NOTES.)
FLOW OLE ANH FM O CL
DAVID COX, P.E. ANDREW BURNS, P.E. CAROLE HARVEY
3 PLAN
5.5' BURY HYDRANT TO BE INSTALLED w/4-1/2" NOZZLE FACING THE ROADWAY
"A"
PROJECT MANAGER PROJECT ENGINEER DESIGNER
1 UNDISTURBED SOIL
N.T.S.
3,000 P.S.I. CONCRETE
12"
MAY BE PRECAST OR CAST-INPLACE SEE NOTE #3
(585) 325-1000 FAX: (585) 325-1691
NO. DATE BY
W
DISINFECTION/BLOW-OFF/SAMPLING TAP
RADIUS NOT LESS THAN 1/2 MANHOLE I.D. 4,000 P.S.I. CONCRETE OR BRICK ASTM C-32 GRADE SS
CONCRETE THRUST BLOCK
5'-0" MIN
8" MIN. DIA. PIPE
FLOW
EXISTING MANHOLE
UNDISTURBED SOIL
IMMEDIATELY PRIOR TO THE AUTHORITY PLACING WATER MAIN IN SERVICE CONTRACTOR SHALL REMOVE ALL CORPORATIONS ASSOCIATED WITH TEMPORARY FACILITIES (I.E. SAMPLING TAPS, ETC.) AND REPLACE WITH THREADED BRASS PLUGS. PLACEMENT OF THREADED BRASS PLUG MUST BE WITNESSED BY A MCWA REPRESENTATIVE.
BRICK TO 1/2 I.D.
PRECAST OR CAST IN PLACE MANHOLE BASE (ASTM C-478) NO NARROWER THAN PIPE DIAMETER
WATER MAIN
242 WEST MAIN ST., SUITE 100 ROCHESTER, NY 14614
H
CUT OUT EXISTING BENCH AND INVERT. SHAPE NEW INVERT BY FILLING IN WITH CONCRETE OR BRICK AS SHOWN ON PLAN. ALL SLOPES ARE 1/2"/FT. MIN. SEE NOTE #5.
MIN.
MORTAR ALL EXTERIOR JOINTS
WATERSTOP-RX OR APPROVED EQUIVALENT
SEAL AROUND DOGHOUSE OPENING
H
MIN.
12"
Jacob Lewis 10/29/2024 11:10 AM
24" MAX.
REINFORCED PRECAST CONCRETE RISER SECTIONS (ASTM C-478)
CONCRETE THRUST BLOCK
10. CONTRACTOR MAY CORE BORE OR DRILL A NEW OPENING IF REQUIRED, NO IMPACT DEVICES WIL BE ALLOWED TO BE USED FOR MAKING NEW HOLES IN EXISTING MANHOLES OR CHAMBERS.
RISER AND COVER SLAB JOINTS AND LIFT HOLES SHALL BE FILLED WITH NON-SHRINK GROUT AND SEALED WITH 2 COATS OF APPROVED BITUMASTIC COAL TAR SEALER
DIAMETER VARIES
COAT INSIDE AND OUTSIDE SURFACES WITH 2 COATS OF APPROVED BITUMASTIC COAL TAR SEALER (ASTM D-450, TYPE B)
Passero Associates
9. CORED OPENINGS IN MANHOLE RISER SECTIONS SHALL BE NOT LESS THAN 6" FROM A RISER JOINT.
FILL ALL AROUND WITH CONCRETE EXCEPT IN PAVEMENT. COAT WITH APPROVED BITUMASTIC COAL TAR SEALER.
ALIGN WITH DOWNSTREAM INVERT
WATER MAIN
8. STUBS 4' MAX. R.C.P. AND D.I.P., 1' MAX. ALL OTHER PIPE MATERIALS, FROM OUTSIDE FACE.
SECTION "A-A"
MANHOLE STEPS AT 12" O.C. SEE DETAIL #7
TEE OR PLUG GRADE
CORPORATION STOP
FLO
Y:\PROJECTS-NEW\2024\20243903\20243903.0002\01_CAD-BIM-MODELS\CIVIL\20243903.0002 DETAILS.DWG
PIPE BEDDING
UNDISTURBED GROUND
24"
TEE OR PLUG
1" COPPER (MIN)
7. THE DISTRICT MUST BE NOTIFIED 48 HRS. IN ADVANCE OF CONSTRUCTION FOR INSPECTION OF CONNECTION.
SLOPE
MARK IV ENTERPRISES 301 EXCHANGE BOULEVARD ROCHESTER, NY 14608
A
WATER MAIN
5. CONTRACTOR MUST COAT ALL DISTURBED AREAS OF MANHOLE WITH TWO (2) COATS OF SIKAGARD NO. 62 FOR INTERIOR OF BASE AND TWO (2) COATS OF SUPER SERVICE BLACK FOR ALL OTHER SURFACES.
FINISHED GRADE
BACKFILL SHALL BE SELECT MATERIAL (NYSDOT SPEC. 203-2.02) IF OUTSIDE PAVEMENT. IF IN PAVEMENT, BACKFILL SHALL BE CRUSHER RUN STONE (NYSDOT SPEC. 304-2.02, TYPE 2)
1" CURB STOP
CLIENT:
6. STUB AT MANHOLE SHALL NOT EXCEED 100 DEGREES ALIGNMENT ENTERING AGAINST EXISTING UPSTREAM SEWER.
WATERTIGHT PICK HOLE
SUPER "O" RING JOINT AND GASKET
12" MIN
4. GENERALLY, A DROP CONNECTION SHALL BE PROVIDED WHEN DIM. "A" EXCEEDS 2' IN A SANITARY MANHOLE.
SEE NOTE #8
OPENING IN ECCENTRIC SLAB SHALL BE ALIGNED WITH STEPS AND DOWNSTREAM INVERT
BRICK OR PRECAST SPACERS (MAX. 3 COURSES) REINFORCED PRECAST CONCRETE FLAT COVER SLAB WITH 24" DIA. ECCENTRIC MASONRY OPENING TO BE DESIGNED AND CONSTRUCTED FOR H-20 LOADING
GRADE C L
3. THE EXISTING MANHOLE BASE MAY BE ROUND OR SQUARE, DEPENDING ON THE TIME THE MANHOLE WAS CONSTRUCTED.
USE FLEXOLITH GEL BY DURAL OR SIKADUR 33 BY SIKA EPOXY MORTAR TO FILL AROUND PIPE. NO SLEEVE REQUIRED.
TAPPING SLEEVE AND VALVE
N.T.S.
2. EXISTING MANHOLE STRUCTURE SHALL BE SUFFICIENTLY BRACED AND PROTECTED TO PREVENT ANY SHIFTING OR DAMAGE TO THE MANHOLE.
SEE NOTE #2 FOR BRACING OF EXISTING MANHOLE.
SLOPE
WATERMAIN TRENCH
1. THE CROWN OF THE NEW SEWER SHALL NOT BE CONSTRUCTED LOWER THAN THE CROWN OF THE EXISTING MAIN SEWER. THE INVERT OF THE NEW SEWER SHALL BE CONSTRUCTED AT LEAST 3" ABOVE THE EXISTING MAIN SEWER INVERT.
STORM SEWERS SHALL NOT BE CONNECTED TO SANITARY SEWERS.
12" MIN
1"=30'
CAST IRON FRAME & COVER TO BE NEENAH R-1726-A OR APPROVED EQUIVALENT WITH MACHINED BEARING SURFACE, AND THE WORD SANITARY PRINTED ON TOP
MJ = MECHANICAL JOINT RJ = RESTRAINED JOINT
NOMINAL PIPE DIA + 24"
1. VALVE BOX SHALL BE CENTERED ON VALVE AND SET ON COMPACTED BACKFILL. GRADE 2. VALVE SHALL NOT SUPPORT VALVE BOX.
6" MJ GATE VALVE SOLID CONCRETE BLOCK (MIN:4"x4"x8") NOTE: ALL PRIVATE HYDRANTS (DOWNSTREAM OF THE MASTER METER) SHALL 3. BEALL BODY AND BONNET BOLTS SHALL BE STAINLESS STEEL. PAINTED "SAFETY RED"
4. ALL VALVES SHALL BE OPEN LEFT EXCEPT VALVES 12" AND SMALLER
PERPENDICULAR HYDRANT ASSEMBLY
WATER VALVE
N.T.S.
N.T.S.
TOWN/CITY: WEBSTER COUNTY: MONROE
MINIMUM HORIZONTAL THRUST BLOCK DIMENSIONS, IN FEET, TO BE POURED AGAINST UNDISTURBED SOIL FITTING
H
W
A
8" x 11-1/4° BEND 8" x 22-1/2° BEND 8" x 45° BEND 8" x 90° BEND
1.0 1.5 2.0 3.0 2.5
2.0 3.0 4.0 6.0 5.0
1.5 1.5 2.0 2.5 2.0
8" TEE OR PLUG
NY
PROJECT NO.:
20243903.0002 DRAWING NO.:
C 204
WIDTH (W) OF BLOCK SHALL NOT EXCEED TWICE THE HEIGHT (H).
HORIZONTAL THRUST BLOCK FOR BENDS
DATE: