60'
SISTENE WAY (60.0' WIDE R.O.W.)
WALL
SECTION 2B
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM & SANITARY SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
LOT 125
THE MEADOWS
SECTION 1 FUTURE SECTION
N/F 800 PHILLIPS ROAD LLC 1563 SISTINE WAY T.A. # 065.02-4-25
ROAD
SECTION 2A
ROAD
PROJECT LOCATION
LOT 126
NORTH
N
LOT 161
N SALT
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-26
ROAD
FUTURE SECTIONS OF BELLA TERRA
ROAD
N/F 800 PHILLIPS ROAD LLC 1562 SISTINE WAY T.A. # 065.02-4-61
GRID
LOT 160
SCHLEGEL
MEADOWS 2
N/F 800 PHILLIPS ROAD LLC 1564 SISTINE WAY T.A. # 065.02-4-60
SHALLOW CREEK TRAIL
PHILLIPS
(60.0' WIDE R.O.W.)
WEBSTER
Y DE WA R E V TERRA R.O.W.
RIGH
800 PHILLIPS ROAD
CARBELLA COURT
SCHLEGEL ROAD SCHOOL ENTRANCE
TOWN OF WEBSTER
STREET
.50'
REMAINING LANDS SALT ROAD (ZONED: LMR) N/F 800 PHILLIPS ROAD LLC 1558 SISTINE WAY T.A. # 065.02-4-63
30.
'
E
" 52
5'
W ' 55" ° 46 S66 6.87' 26
34
3.8
32
S
N03° 46' 38"W 208.26'
S79° 08' 27"W 22.70'
49' . 3 6
30"W S79° 29' 270.53'
N/F 800 PHILLIPS ROAD LLC 1555 SISTINE WAY T.A. # 065.02-4-28
° 35
8'
7.4 13
∆=7°56'43" R=370.00' L=51.31' CHD=N52°36'37"W 51.27'
25
156.78' N86° 19' 14"W
146.35' N88° 19' 43"E 146.35'
S87° 06' 36"W 148.22'
S85° 11' 32"W 181.06'
LOCATION SKETCH ' 29 "W
NOT TO SCALE
302
'0
2"W
12 0.0
0' S88° 56' 38"W 32.23' PROPOSED TEMPORARY TURN AROUND EASEMENT TO THE TOWN OF WEBSTER
N3
3°
25'
4' 58 "
°3
10+00
S5 6
S85° 11' 32"W 217.86'
S85° 11' 32"W 254.66'
.0' 30
22.70'
130.27'
.76'
.16'
02" E LOT 215 ∆=12°42'35" 60. N/F 00' ' .99 19' 77 13,550 SQ.FT. 80. W 24" 53' ROW 2° R=370.00' L=82.08' N0 800 PHILLIPS ROAD LLC 1554 SISTINE WAY 0.311 AC. CHD=N42°16'58"W MONUMENT 74.05' T.A. # 065.02-4-65 PROPOSED WATERMAIN 81.91' EASEMENT TO MONROE LOT 165 6.15' LOT 216 COUNTY WATER AUTHORITY 13,904 SQ.FT. ∆=7°40'24" 9' S87° 06' 36"W 0 . N/F 0.319 AC. R=430.00' L=57.59' 52.38' 23 800 PHILLIPS ROAD LLC 3 CHD=S52°44'46"E 1553 SISTINE WAY ' T.A. # 065.02-4-29 "E 28 57.55' . ' 3 9 LOT 217 4 5 ' 4 ∆=12°42'35" LOT 129 7 1 3 14,055 SQ.FT. E 2. °4 R=370.00' L=82.08' 0 00 3 " 5 + 3 LOT 218 4 3 9 0.323 AC. CHD=N29°34'23"W 1' LOT 219 LOT 220 =S E °4 " 15,495 SQ.FT. D 0 81.91' 1 H 3 12,566 SQ.FT. 14,884 SQ.FT. '0 N/F LOT 214 0.356 AC. 'C =S LOT 221 2 5 D 800 PHILLIPS ROAD LLC 0.288 AC. LOT 224 ∆=7°40'24" 0.342 AC. 2 LOT 223 H LOT 222 .3 23,244 SQ.FT. ° 10,301 SQ.FT. ∆=12°42'35" C 4 T.A. # 065.02-4-30 3 10,704 SQ.FT. R=430.00' L=57.59' 6' 32 0.534 AC. 15,535 SQ.FT. 0.236 AC. =3 R=370.00' L=82.08' 18,703 SQ.FT. .4 S LOT 130 L 1 N/F = ' 6 0.246 AC. CHD=S45°04'21"E ∆=4°48'58" 0 3 ∆=5°42'01" 0.356 AC. 800 PHILLIPS ROAD LLC = ' 0.429 AC. CHD=N16°51'47"W .0 HD 'L T.A. # 065.02-4-66 57.55' R=1530.00' 70 C ' .89 57"W 0 R=370.00' L=36.81' 3 ∆=0°27'21" 5 0 81.91' 0 ' = 3 3' 5 R 0. LOT 213 8 . L=128.61' 1 " 0 4 CHD=N07°39'29"W 9 LOT 166 2 . ∆=9°59'09" R=1530.00' 2 35' FRONT =4 18 ' ° 3 21,110 SQ.FT. 6 R ∆=1°36'12" 1 CHD=N02°18'50"E ∆=1°55'04" 00 36.80' 45 9" ∆=4°57'58" 1°4 SETBACK R=1970.00' 36 E L=12.17' 8+ 5 2 " N = ' = 0.485 AC. ∆ R=1970.00' 6 4 128.57' R=1970.00' 4 TYP. 'L R=1970.00' L=343.34' CHD=S04°57'00"W '5 ∆=7°40'24" 5 1° 0 3 = L=55.13' ∆ L=65.94' .0 3 34.72' L=170.75' CHD=S00°11'06"W 12.17' R=430.00' L=57.59' 30 6° 63.00' CHD=S02°52'40"W 4 CHD=N03°50'56"W 4 = CHD=N00°24'25"W 342.91' S 1' CHD=S37°23'57"E 63.0 STA 6+18.05 TERRA VERDE WAY EQUALS 0.73' 55.13' "R 65.94' 4 N04° 48' 28"W 16 STA 18+90.52 ARROWWOOD TRAIL 170.70' 5 ∆=5°16'19" 57.55' ' 25 7+00 ° P. C. STA 1+38.02 ∆=7°40'24" R=1530.00' ∆=0°56'13" 8 ∆ = 9 ° 5 9 ' 0 9 " R = 1 9 7 0 . 0 0 ' L = 3 4 3 .3 4 ' C H D = S 0 0 ° 1 1 ' 0 6 " W 3 4 2 . 9 1 ' P. C. STA 6+47.32 P. T. STA 4+86.59 ∆ =4 R=430.00' L=57.59' L=140.78' R=1470.00' EASEMENT TO BE ABANDONED 00 0+00 6+ LOT 212 CHD=S29°43'33"E 3' CHD=N02°32'31"E1+00 0.7 L=24.04' IN THE RIGHT OF WAY N04° 48' 28"W 16 5+00 21,971 SQ.FT. ∆=5°16'19" 57.55' 140.73' CHD=N00°33'45"W ∆=82°44'41" 2+00 ∆=7°40'24" WAY E D 4+00 R E 0.504 AC. V 3+00 A R=1470.00' R ∆=5°16'19" R=1500.00' R 24.04' R=30.00' L=43.33' TE ∆=93°54'44" R=430.00' L=57.59' .W.) L=138.02' ∆ = 9 ° 5 9 ' 0 9 " R = 2 0 0 0 . 0 0 ' L = 3 4 8 .5 7 ' C H D = S 0 0 ° 1 1 ' 0 6 " W 3 4 8 .1 3 ' L=135.26' (60.0' WIDE R.O R=30.00' L=49.17'CHD=N49°31'24"W CHD=S22°03'08"E CHD=N02°32'31"E LOT 211 CHD=N02°32'31"E 39.66' ROW CHD=N42°08'54"E 57.55' 34.55' 137.97' S01° 01' 51"E ∆=10°03'53" 2' .2 22,427 SQ.FT. 67 MONUMENT 135.21' "W 28 ' N04° 48 43.85' R=430.00' L=75.53' ROW ∆=0°56'13" 0.515 AC. ∆ = 9 ° 5 9 ' 0 9 " R = 2 0 3 0 . 0 0 ' L = 3 5 3 .8 0 ' C H D = S 0 0 ° 1 1 ' 0 6 " W 3 5 3 . 3 5 ' MONUMENT CHD=S13°11'00"E R=1470.00' ∆=3°06'19" 35' FRONT 75.44' L=24.04' ∆=1°46'42" ∆=82°44'41" R=1470.00' ∆=1°21'48" ∆=1°46'44" SETBACK CHD=N00°33'45"W R=2030.00' R=30.00' L=43.33' TYP. L=79.67' R=2030.00' R=2030.00' ∆=1°46'45" 24.04' L=63.00' CHD=N49°31'24"W CHD=S02°17'44"W ∆=1°19'47" L=48.30' L=63.03' R=2030.00' CHD=N00°46'36"W S01° 01' 51"E 34.55' 39.66' 79.66' R=1470.00' CHD=S04°07'35"E CHD=S02°33'19"E L=63.04' ∆=0°50'13" 63.00' S04° 48' 28"E 52.41' L=34.11' 48.30' 63.03' CHD=S01°00'08"W R=1470.00' ∆=0°33'53" LOT 210 CHD=S04°30'47"W 63.04' L=21.48' R=2030.00' 18,317 SQ.FT. 34.11' S04° 48' 28"E 14.81' CHD=N00°19'28"E L=20.00' ∆=3°17'10" LOT 209 LOT 202 0.421 AC. 21.47' 28,300 SQ.FT. ' R=2030.00' CHD=S00°06'45"W 16,194 SQ.FT. 9 30 .2 .0 0.650 AC. L=116.43' 20.00' LOT 208 0.372 AC. ' ' 07 9 2 N/F LOT 207 LOT 205 7 LOT 201 LOT 203 LOT 206 CHD=S03°32'05"W . 16,198 SQ.FT. 800 PHILLIPS ROAD LLC LOT 204 2 "E 11,968 SQ.FT. 535 TERRA VERDE WAY 11,741 SQ.FT. 11,793 SQ.FT. 116.41' 17 54 0.372 AC. 16,490 SQ.FT. 29,138 SQ.FT. ' 11,813 SQ.FT. T.A. # 065.02-4-31 E 0.275 AC. 3 " 3 0.270 AC. 4 0.271 AC. 0.378 AC. 0.669 AC. 0.271 AC. LOT 131 6° '5 LOT 128
297
° 23
S3
3°
"W
'
PROPOSED DRAINAGE EASEMENT TO THE TOWN OF WEBSTER
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM & SANITARY SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
LOT 164
3 5°
97' . 2 7
S20
' 29
90 .00
S3
° 23
E
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 1556 SISTINE WAY T.A. # 065.02-4-64
E
2"
S20
10+96
9' 8.3 23 W ' 5" 9 ' 4 8.3 21 23
5 4'
N3
' .09 240 6' W 72.9 51"
1° S4
5°
7.0
32
05'
32.88'
W 20" 04' 9' 4° S5 257.1
BELLA TERRA SECTION 1
0'
68'
ORCHARD .87' 44"E 292 S07° 15'
E
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-27
18.14'
"W 99 N07° 38' 45 25.76' 22.72'
4' 58 "
LOT 163
LOT 127
44 S07° 15'
°3
.) (60.0' WIDE R.O.W
LOT 162
' "E 307.82
N 1181475.01 E 813836.94 GRID
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
S5 6
T CARBELLA COUR
ROAD
N/F 800 PHILLIPS ROAD LLC 1560 SISTINE WAY T.A. # 065.02-4-62
S3
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
3°
25' 0 323 2"W .45 323 ' .45
REMAINING LANDS SALT ROAD (ZONED: LMR)
'
35.0'
04
W
W 1"
1"
'0
'0
04
W 7" '2 05 8' 1° 4.1 S4 32
9°
9°
S88° 56' 38"W 113.58' 113.58'
'
13
'
53 8.
1. 21
22
8"W '3 03 ' 9° .38 S4 231
1.
"LMR" LOW-MEDIUM RESIDENTIAL DISTRICT
2.
065.002-01-04.220
3.
PROJECT BULK DATA - TOWNHOUSES
APPROXIMATE LOCATION TOWN LOT 12
TRA
(60.0' WIDE R.O.W.)
IDE
0' W
FUTURE SECTIONS MEADOWS TWO SUBDIVISION 4.
a. MINIMUM BUFFER (NON-RESIDENTIAL)
REQUIRED 50 FT.
PROPOSED 50 FT.
b. MINIMUM BUFFER (RESIDENTIAL)
150 FT.
150 FT.
c. MINIMUM WIDTH DWELLING UNIT
20 FT.
42± FT.
d. MAXIMUM BUILDING HEIGHT
30 FT.
< 30 FT.
e. MAXIMUM BUILDING LENGTH
165 FT.
84± FT.
f. MINIMUM HABITABLE FLOOR AREA (PER UNIT)
1,000 SQ. FT.
2,160 SQ. FT.
g. MAXIMUM UNIT DENSITY
6 UNITS/ACRE
1.9 UNITS/ACRE
h. MINIMUM DISTANCE BETWEEN STRUCTURES
40 FT.
40 FT.
i. MINIMUM DRIVEWAY SEPARATION
5 FT.
5 FT.
j. MAXIMUM IMPERIOUS AREA
75%
19.8%
REQUIRED
PROPOSED
N/A
35 FT.
PROJECT DATA FRONT SETBACK
SPECIAL NOTES 1. ALL THE IMPROVEMENTS SHALL BE CONSTRUCTED ACCORDING TO THE SPECIFICATIONS OF THE TOWN OF WEBSTER.
(60.
ARR OW
WO OD
TOWN OF WEBSTER OPEN SPACE
)
IL
LOT 120
MEADOWS TWO SUBDIVISION
SITE DATA
REMAINING LANDS SALT ROAD (ZONED: LMR)
APPROXIMATE LOCATION TOWN LOT 14
LOT 121
N/F XEROX CORPORATION T.A. # 65.020-01-040.110 750 PHILLIPS ROAD
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
.W.
LOT 122
LOT 123
N 1180992.89 E 813428.46 GRID
APPROXIMATE LOCATION TOWN LOT 6
R.O
LOT 125
N01° 03' 22"W 145.87'
S88° 56' 38"W 125.79' 125.79'
ARROWWOOD TRAIL
W 15" 26' 0' 6° S5 319.2
S89° 04' 45"W 90.06'
16+00
LOT 127
133.37'
APPROXIMATE LOCATION TOWN LOT 12
15+71
LOT 124
12.50'
N40° 55' 59"W 20.00'
"W ' 39 ° 06 S64 65.91' 2
N00° 53' 44"W 20.00'
S00° 55' 15"E 60.00'
LOT 126
PROPOSED DRAINAGE & STORM SEWER EASEMENT TO THE TOWN OF WEBSTER
23.19'
110.35'
97.32' S00° 55' 15"E
168.61'
60.00' N00° 55' 15"W
S89° 04' 45"W 90.06'
PROPOSED BIO RETENTION BASIN
PROPOSED DRAINAGE & STORM SEWER EASEMENT TO THE TOWN OF WEBSTER
S89° 06' 16"W 20.00'
S00° 55' 25"E 283.25'
APPROXIMATE LOCATION 100' WIDE EASEMENT TO ROCHESTER GAS & ELECTRIC CORPORATION PER LIBER 4944 PAGE 33
4"W 47' 0 S71° .74' 230
63.00'
63.00' S00° 55' 15"E 1105.34'
N00° 53' 44"W 20.00'
17+00
60.12' N89° 06' 16"E
84.25'
S89° 06' 16"W 174.54' S89° 06' 16"W 174.54'
18+00
N89° 06' 16"E 165.58' S89° 06' 16"W 165.57'
N 1182241.57 E 813282.27 GRID
63.00'
63.00'
150.02'
79.54'
191.97' S89° 04' 45"W
PROPOSED STORMWATER & STORM SEWER EASEMENT TO THE TOWN OF WEBSTER
S89° 06' 16"W 319.94'
35.0'
188.26' S89° 04' 45"W
S00° 55' 14"E 263.28'
186.46' S89° 04' 45"W
80.06'
186.62' S89° 04' 45"W
.97' E 129 1' 27"
188.74' S89° 04' 45"W
PROPOSED DRAINAGE EASEMENT TO THE TOWN OF WEBSTER
0' 114.8
S89° 04' 45"W 30.40'
5 S11°
S4
33
201.01' S89° 04' 45"W
E 1' 27" S11° 5
S
° 46
S89° 04' 45"W 126.33'
S89° 04' 45"W 186.83'
LOT 132
205.48' S89° 04' 45"W
206.03' N89° 04' 45"E 206.03'
N/F 800 PHILLIPS ROAD LLC 531 TERRA VERDE WAY T.A. # 065.02-4-32
S4
S4
18+91
60' R.O.W.
60.00' N89° 54' 21"E 60.00'
TERRA VERDE WAY
2. ALL ROADWAY CONSTRUCTION TO BE IN ACCORDANCE WITH THE SPECIFICATIONS AND REGULATIONS SET FORTH BY THE TOWN OF WEBSTER. 3. ALL SITE WORK IS TO BE IN COMPLIANCE WITH THE STANDARDS OF THE TOWN OF WEBSTER. 4. PRESERVE ALL MATURE TREES ON SITE, WHERE POSSIBLE, AND MARK SAID TREES BY THE DEVELOPER'S ENGINEER PRIOR TO THE COMMENCING OF ANY SITE WORK.
SITE LINE & SYMBOL LEGEND REAL PROPERTY TAX SERVICE: SECTION/PARCEL BOUNDARY
APPROVALS
MONROE COUNTY DEPARTMENT OF HEALTH REALTY SUBDIVISION CONDITIONS OF APPROVAL :
RIGHT-OF-WAY LINE ADJACENT PROPERTY LINE
1.
THAT THE PROPOSED FACILITIES FOR WATER SUPPLY AND SEWAGE DISPOSAL ARE INSTALLED IN CONFORMITY WITH SAID PLANS ON FILE WITH THE MONROE COUNTY DEPARTMENT OF HEALTH.
MIN. BUILDING SETBACK
2.
THAT NO LOT OR REMAINING LAND (IF APPLICABLE) SHALL BE SUBDIVIDED WITHOUT PLANS, FOR SUCH RESUBDIVISION, BEING SUBMITTED TO AND APPROVED BY THE MONROE COUNTY DEPARTMENT OF HEALTH.
3.
THAT AN ORIGINAL SUBDIVISION MAP, AS APPROVED THIS DATE, SHALL BE FILED IN THE OFFICE OF THE CLERK OF THE COUNTY OF MONROE PRIOR TO OFFERING LOTS FOR SALE.
4.
THAT THE OWNER OF THE SUBDIVSION SHALL FURNISH EACH PURCHASER, OF A LOT, WITH A COPY OF THE APPROVED PLAN, OR IN THE CASE OF SALE OF DEVELOPED LOTS, THE OWNER OF THE SUBDIVISION SHALL FURNISH EACH PURCHASER WITH AN ACCURATE "AS-BUILT" PLAN DEPICTING ALL INSTALLED FAC- ILITIES INCLUDING SANITARY SEWAGE, STORM WATER AND WATER SUPPLY.
5.
THAT ADEQUATE EROSION/SILTATION CONTROL MEASURES SHALL BE EMPLOYED PRIOR TO AND DURING CONSTRUCTION. IF THE PROJECT WILL RESULT IN THE DISTURBANCE OF ONE ACRE OR MORE, COVERAGE UNDER THE NYSDEC SPEDES GP 0-15-002 FOR STORM WATER DISCHARGE FOR CONSTRUCTION ACTIVITIES WILL BE OBTAINED.
CENTER LINE
BY:
TOWN ENGINEER
EXIST. CONCRETE CURB EXIST. EDGE OF PAVEMENT
SURVEY NOTES THE DEVELOPER'S AND CONTRACTOR'S ATTENTION IS DIRECTED TO LOCAL LAW NO. 6 OF 2019, REGARDING LIABILITY INCURRED THROUGH DISTURBANCE OR DESTRUCTION OF GEODETIC SURVEY MONUMENTS.
PROPOSED BUILDING
THE DEVELOPER AND CONTRACTOR MUST LOCATE, MARK, BARRICADE, SAFEGUARD AND PRESERVE ALL SURVEY CONTROL MONUMENTS AND RIGHT-OF-WAY MONUMENTS IN THE AREAS OF CONSTRUCTION. FOR DESCRIPTIVE AND SURVEY DATA FOR GEODETIC CONTROL MONUMENTS GO TO THE COUNTY OF MONROE SURVEYORS OFFICE WEBSITE AND ACCESS THE GIS BASED INTERNET WEB VIEWER, OR CONTACT THE MONROE COUNTY SURVEYORS OFFICE.
PROPOSED LOT LINE
PROPOSED CONCRETE CURB
BY:
PLANNING BOARD CHAIRPERSON
BY:
6.
TOWN HIGHWAY SUPERINTENDENT
EXIST. EDGE OF PAVEMENT EXISTING UTILITY POLE, GUY ANCHOR & POLE W/LIGHT
2.
TOPOGRAPHIC SURVEY WAS CONDUCTED ON MAY 11, 2023.
MAP ENTITLED "XEROX SUBDIVISION MAP" PREPARED BY BERGMANN ASSOCIATES DATED JUNE 10, 2008, HAVING PROJECT NUMBER 6912.10 AND IS FILED IN THE MONROE COUNTY CLERK'S AS LIBER 336 OF MAPS PAGE 41. THE DEEDS AS SHOWN ON FILE IN THE MONROE COUNTY CLERK'S OFFICE. BOOK 10731 OF DEEDS PAGE 75 (LOT 1 LIBER 336 MAPS, PAGE 41) MAP ENTITLED "BELLA TERRA SUBDIVISION SECTION 1" PREPARED BY COSTICH ENGINEERING DATED MARCH 13, 2020, HAVING PROJECT NUMBER 4500.10 AND IS FILED IN THE MONROE COUNTY CLERK'S AS LIBER 362 OF MAPS PAGE 43 AND 44.
Monroe County Surveyors Office
BY
PUBLIC HEALTH ENGINEER
DATE
PROJECT MANAGER
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
GRAPHIC SCALE 40
0
20
80
40
T
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
160
( IN FEET ) 1 inch = 40 ft. NO.
DATE
REVISION
BY
CHKD.
APVLS.
EL
HI
C
TITLE OF PROJECT
W.T.A.
OF NEW Y E T.
Civil Engineering
DRAWN BY
W.T.A. J.S.F. TOPO/BASE
L. S. 49 N O. 0 5 0 4 S V ED UR L AND S
Landscape Architecture
G.L.R.
PLAT MAP SECTION 2A PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
1"=40'
BELLA TERRA SUBDIVISION SECTION 2
TITLE OF DRAWING
Land Surveying
BOUNDARY
R
1.
EASEMENT DIMENSION
I
REFERENCES
XX.XX'
Daniel T. Hickok, N.Y.S. L.S., No. 050449
FIRE MARSHAL
3.
8.
DATE:
YO
ELEVATIONS ARE REFERENCED TO MONUMENT 1128-3 (NYGS) 1940 & 1972, REFERENCED TO THE NATIONAL GEODETIC VERTICAL DATUM OF 1929, (ELEV.=353.736)
BY:
E
7.
DIRECTOR OF PUBLIC HEALTH County Highway Superintendent For the Monroe County Monumentation Law
EN
ALL DISTANCES SHOWN ON THIS MAP ARE REFERENCED TO THE GROUND.
TOWN ASSESSOR
LI C
6.
BY:
THAT THIS MAP WAS PREPARED FROM NOTES OF AN INSTRUMENT SURVEY COMPLETED ON MAY 11, 2023 AND FROM THE REFERENCE(S) LISTED HEREON. NO SEARCH OF RECORDS, OTHER THAN THOSE REFERENCED, WAS MADE FOR EASEMENTS OR ENCUMBRANCES AFFECTING THIS PARCEL.
K
USING A COMBINED SEA LEVEL AND COMBINED FACTOR OF 1.0000329, TIES TO MONUMENTATION WAS MADE USING APPROPRIATE PROCEDURES TO OBTAIN AN INDICATED ACCURACY OF 1:20,000 OR BETTER.
911 APPROVAL:
This plat is approved in accordance with the provisions of Section 239-F, Article 12-B of the General Municipal Law and/or the Monroe County Monumentation Law. A separate approval is required for site construction. For the General Municipal Law:
RK O OK
5.
EXIST. RIGHT-OF-WAY LINE
THE HORIZONTAL DATUM SHOWN HEREON IS REFERENCED TO THE NEW YORK STATE PLANE COORDINATE SYSTEM OF 1927, WEST ZONE, TRANSVERSE MERCATOR PROJECTION, NAD 27 THROUGH CONTROL TIES TO THE FOLLOWING GEODETIC MONUMENTS N=1,182,944.36 E=811,944.70 (NAD 1927) N=1,182,986.24 E=814,040.05 (NAD 1927)
WEBSTER SEWER DISTRICT
REALTY SUBDIVISION APPROVAL THIS IS TO CERTIFY THAT APPROVED PLANS FOR WATER SUPPLY AND SEWAGE DISPOSAL FOR THIS PROJECT ARE ON FILE IN THE OFFICE OF THE MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH. CONSENT IS HEREBY GIVEN FOR THE FILING OF THIS MAP IN THE MONROE COUNTY CLERK'S OFFICE IN ACCORDANCE WITH ARTICLE III OF THE MONROE COUNTY SANITARY CODE
EXIST. EASEMENT LINE
THIS PROJECT IS LESS THAN 5000 FEET FROM THE NEAREST GEODETIC SURVEY MONUMENT AND THIS PROJECT IS TIED INTO THE MONROE COUNTY GEODETIC MONUMENTATION NETWORK
1139-5 (NYGS) 1940/1982 1139-4 (NYGS) 1940/1982
BY:
-
MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH MONROE COUNTY SURVEYORS OFFICE:
N
4.
EXIST. ADJOINING PROPERTY LINE
WE, COSTICH ENGINEERING, D.P.C., HEREBY CERTIFY T0
DA
3.
PROPOSED EASEMENT LINE
THAT PLAN APPROVAL IS LIMITED TO 5 YEARS. TIME EXTENSIONS FOR PLAN APPROVAL MAY BE GRANTED BY THE MONROE COUNTY DEPARTMENT OF HEALTH BASED UPON DEVELOPMENTAL FACTS AND THE REALITY SUBDIVISION REGULATIONS IN EFFECT AT THAT TIME. A NEW PLAN SUBMISSION MAY BE REQUIRED TO OBTAIN A TIME EXTENSION.
CERTIFICATION
A
2.
6. THE DEED RESTRICTIONS FOR THE PROPERTY SHALL INCORPORATE THE DEFINITION OF THE PROPERTY LIMITS AND THE CONDITION OF DISTURBANCE BEYOND THE PROPERTY LIMITS.
ST
1.
CENTER LINE
5. COMPLY WITH ALL REQUIREMENTS OF ANY FEDERAL, STATE, COUNTY OR TOWN AGENCY.
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA100 SHEET 1 OF 9
SHALLOW CREEK TRAIL
N
GRID
VERDE WAY (60.0' WIDE R.O.W.) 23+00
24+00
25+00
'
4"W 182.4
8'
NORTH
182.48' N 1180981.31 E 814649.77 GRID
6.04'
PROPOSED STORM & SANITARY SEWER EASEMENT TO THE TOWN OF WEBSTER
' 26"E 13 S82° 00
117.21'
∆=3°58'04" R=2130.00' L=147.51' CHD=N83°27'16"W 147.48'
' 24"E
S08° 32' 07"W 25.77'
VERDE WAY (60.0' WIDE R.O.W.)
∆=0°48'32" R=2130.00' L=30.07' CHD=N85°18'14"W 30.07' 1.
"LMR" LOW-MEDIUM RESIDENTIAL DISTRICT
2.
065.002-01-04.220
3.
TOWNHOUSES a. MINIMUM BUFFER (NON-RESIDENTIAL) b. MINIMUM BUFFER (RESIDENTIAL) c. MINIMUM WIDTH DWELLING UNIT
28+00
FUTURE SECTIONS OF BELLA TERRA SUBDIVISION
SITE DATA
REMAINING LANDS SALT ROAD (ZONED: LMR)
MILANO TRAIL (60.0' WIDE R.O.W.)
d. MAXIMUM BUILDING HEIGHT e. MAXIMUM BUILDING LENGTH
PROPOSED 50 FT.
150 FT.
150 FT.
20 FT.
42± FT.
30 FT.
< 30 FT.
165 FT.
84± FT.
f. MINIMUM HABITABLE FLOOR AREA (PER UNIT)
1,000 SQ. FT.
2,160 SQ. FT.
6 UNITS/ACRE
1.9 UNITS/ACRE
i. MINIMUM DRIVEWAY SEPARATION j. MAXIMUM IMPERIOUS AREA 4.
REQUIRED 50 FT.
g. MAXIMUM UNIT DENSITY h. MINIMUM DISTANCE BETWEEN STRUCTURES
28+38
LOT 155
REMAINING LANDS 83.213 ACRES FUTURE BELLA TERRA SUBDIVISION
27+00
' 57"E 2
35.0'
25.37'
S76° 5 5' 38"E 60.00'
S78° 28' 38"W 10.08'
' 16"W N81° 45
136.96' 26+00
S89° 13' 19"E 164.81'
S89° 13' 19"E 155.38'
APPROXIMATE LOCATION TOWN LOT 12
APPROXIMATE LOCATION TOWN LOT 14
S80° 47 ' 57"E 2 29.18'
S80° 47
S85° 30' 54"E 220. 97' 220.97'
211.98' N89° 43' 56"W
SISTE NE W AY (60.0' WIDE R.O.W .) CONC. HEADWALL
4"E 247.0 4
N08° 36
ROAD
N08° 36' 2
SALT
69.21' 245.35'
WAY N1STA 0° 4+56.15 16' 40VERDE "E 170.70'
11,133 SQ.FT. ∆=1°49'16" 0.255 AC. R=2070.00' L=65.80' CHD=N80°37'58"W 65.79'
S08° 27' 2
60.62'
'
S04° 05' 08"W 147.05'
STA 0+00 BELLORA WAY EQUALS
∆=2°25'01" R=2100.00' L=88.58' CHD=N80°17'53"W LOT 230 88.58'
PROPOSED 15' WATERMAIN EASEMENT TO MONROE COUNTY WATER AUTHORITY
' 24"E
SECTION 2B
N 1182074.66 E 814417.63 GRID
.91'
N08° 36
' 76.48
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
53"E 35
25.5'
FUTURE SECTION
∆=3°58'04" R=2130.00' L=147.51' CHD=N83°27'16"W 147.48'
REMAINING LANDS SALT ROAD (ZONED: LMR)
N08° 14' 0 6"E ∆=2°40'31" 156.88' R=830.00' L=38.75' CHD=S80°25'38"E ∆=0°37'57" 38.75' R=2070.00' LOT 229 L=22.85' CHD=N79°24'21"W10,551 SQ.FT. 22.85' 0.242 AC.
P. C. STA 4+29.43
15.0'
SECTION 2A
MEADOWS 2
LOT 259 LOT 260 10,977 SQ.FT. 0.252 AC. 21,347 SQ.FT. 0.490 AC.
9,554 SQ.FT. 0.219 AC.
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
61.32'
LOT 258
∆=1°41'55" R=830.00' L=24.60' CHD=N89°10'03"E 24.60' S01° 42' 25"E 142.44' ∆=4°04'07" R=830.00' L=58.94' CHD=S87°56'56"E 58.93' LOT 227
LOT 228 9,940 SQ.FT. ∆=4°08'59" 0.228 AC. R=830.00' L=60.11' CHD=S83°50'23"E 60.10'
∆=82°19'25" R=30.00' L=43.10' CHD=S40°23'02"E 39.49'
60.06' S11° 02 ' 21"W
∆=97°44'58" R=30.00' L=51.18' CHD=N49°39'10"E 45.20'
8,944 SQ.FT. 0.205 AC.
68.69'
68.57'
LOT 226
71.78'
S00° 46' 41"W 169.78' 101.21'
S01° 40' 54"E 142.05'
∆=12°35'32" R=830.00' L=182.41' CHD=S85°23'09"E 182.05'
∆=97°44'58" 0+00 R=30.00' L=51.18' CHD=N49°39'10"E∆=2°27'14" 45.20' R=2070.00' L=88.65' CHD=N80°18'59"W 88.64'
NOT TO SCALE
LOT 225 21,201 SQ.FT. 0.487 AC.
N88° 17' 35"E 487.66' 73.64'
PROPOSED 30' DRAINAGE EASEMENT TO THE TOWN OF WEBSTER
P. C. STA 0+35.91
LOCATION SKETCH
62.91'
7"W
N10° 10'
149.32'
464
.70'
°4 N18
ROW MONUMENT
91
0
38.37'
' 1' 2
'
' 57.31
1+00
22+00 S88° 19' 06"W 253.61'
66.29
78.07'
27"W
59.57'
N1
1' 8° 4
'
58.34
N00° 46' 41"E 174.25'
2+00
250.58'
59.83
44.77'
63.00' N88° 17' 35"E 343.48'
' 25"W 151.98' N04° 23
LOT 121
0.248 AC.
∆=9°24'13" R=175.00' L=28.72' CHD=N05°28'47"E 28.69'
P. T. STA 0+64.63
9,742 SQ.FT. 9,754 SQ.FT. 0.224 AC. 0.224 AC.
10,381 SQ.FT. 0.238 AC. 10,792 SQ.FT.
99.37' N00° 46' 41"E 188.64'
P. C. STA 2+38.88
∆=4°07'35" R=970.00' L=69.86' CHD=N01°17'07"W 69.85'
LOT 257
' 10.0
75.41' 98' N04° 23' 25"W 151.
76.57'
N/F 800 PHILLIPS ROAD LLC 1574 SISTINE WAY T.A. # 065.02-4-55
∆=4°05'30" R=970.00' L=69.27' CHD=N09°31'15"W 69.25'
67.41'
ROW MONUMENT
∆=4°07'35" R=970.00' L=69.86' CHD=N05°24'42"W 69.85'
LOT 255
' 20.0
' 25"W 146.35' N04° 23
N/F 800 PHILLIPS ROAD LLC 1575 SISTINE WAY T.A. # 065.02-4-21
' 7 73.20 465.8 W ' 27" 8° 41
=N
35' FRONT SETBACK TYP.
' 74.42
LOT 120 N/F 800 PHILLIPS ROAD LLC 1576 SISTINE WAY T.A. # 065.02-4-54
' 30.0
N1
N85° 30' 54"W 20.24' EXISTING DRAINAGE EASEMENT TO THE TOWN OF WEBSTER PER LIBER 362 OF MAPS PAGE 44
.22' 468
"W
N/F 800 PHILLIPS ROAD LLC 1577 SISTINE WAY T.A. # 065.02-4-20
14,703 SQ.FT. 14,208 SQ.FT. 0.337 AC. 0.326 AC.
S81° 58' 02 191.71'
LOT 153
12,412 SQ.FT. 13,447 SQ.FT. 0.285 AC. 0.309 AC.
S86° 07' 03"W 208.58'
N/F 800 PHILLIPS ROAD LLC 1578 SISTINE WAY T.A. # 065.02-4-53
LOT 250
LOT 252
' 02"W S77° 49 180.59'
LOT 119
N88° 17' 35"E 340.55'
N/F 800 PHILLIPS ROAD LLC T.A # 065.02-4-19
LOT 251
97
3 2 ' CHD
∆=2°23'30" R=1030.00' L=43.00' CHD=N00°25'04"W 42.99' 21.86'
∆=3°53'24" R=770.00' L=52.28' CHD=S83°29'26"E 52.27' ∆=82°19'25" R=30.00' L=43.10' CHD=S40°23'02"E 39.49'
8"E
ORCHARD
0 9'
35.0'
∆=10°08'10" R=770.00' L=136.22' CHD=S86°36'49"E 136.04'
∆=12°35'32" R=800.00' LOT 234 L=175.82' 10,167 SQ.FT. CHD=S85°23'09"E 175.47' 0.233 AC.
21,997 SQ.FT.23,034 SQ.FT. 0.529 AC. 0.505 AC.
3 1 8 .8 7 ' 0 8 °4 0 '5 7 "W
LOT 256
"W 40' 01 S73° 3' 174.9
LOT 152
∆=4°09'01" R=830.00' L=60.12' CHD=S01°48'27"E 60.11'
∆=4°09'01" R=830.00' L=60.12' CHD=S10°06'28"E 60.11'
5" R=
=3 2 0 . 0 .0 0 ' L
∆=4°05'30" R=970.00' L=69.27' CHD=N13°36'45"W 69.25'
∆=1°48'36" R=830.00' L=26.22' ∆=4°09'01" CHD=S17°14'16"E R=830.00' L=60.12' 26.22' ∆=2°29'05" CHD=S14°15'28"E R=970.00' L=42.06' 60.11' CHD=N16°54'02"W 42.06' LOT 253 LOT 254 11,706 SQ.FT. 11,799 SQ.FT. 0.269 AC. 0.271 AC.
'
135.65' N88° 17' 35"E
LOT 249
∆=4°09'01" R=830.00' L=60.12' CHD=S05°57'27"E 60.11'
4 6 .6 3
20.0'
144.98' N86° 51' 00"E
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
4 2 ' 0 6 "E 3 ° 2 0 S = HD
135.61' N88° 17' 35"E
6+00
7+00
C
5+00
P. C. STA 2+53.61
∆=1°21'24" R=770.00' L=18.23' CHD=N88°59'48"E 18.23' N01° 42' 25"W ∆=4°53'21" 141.96' R=770.00' L=65.71' CHD=S87°52'49"E 65.69' LOT 233
'
.52
35' FRONT SETBACK TYP.
N00° 46' 41"E 137.70'
LOT 235
LOT 236
3+00
158.67' "E N82° 31' 30
∆=4°09'01" R=830.00' L=60.12' CHD=S02°20'34"W 60.11'
5" R
3'
AY E' LLORA W B 3 7 . 8 .) 32 '5 7 "W IDE R.O.W 00.0' W 0 8 °4 0 (6 +0 N 4 = D CH
167.97' ' 00"E N78° 26
∆=8°39'18" R=830.00' L=125.38' CHD=S08°44'43"W 125.26'
20' ∆ = 3 1 °1 2 ' 5 6 " R = 8 3 0 . 0 0 ' L = 4 5 2 .
5 5 '1
3 3 0 .2
°5 5 '1 ∆ =1 8
8+00
ROW MONUMENT
338.64' N88° 17' 35"E
E
° ∆ =1 8
P. C. STA 5+69.11
=1 0 0
' L= 0 .0 0
4 1 4 .3 4 '
PORTION OF EASEMENT TO BE ABANDONED IN THE RIGHT OF WAY ' ∆ = 3 1 ° 1 2 ' 5 6 " R = 8 0 0 . 0 0 ' L = 4 3 5 .8 5 ' C H D = S 0 2 ° 3 2 ' 0 6 " E 4 3 0 .4 8 9+00
340.58' N88° 17' 35"E
∆=4°49'54" R=770.00' L=64.93' ∆=4°52'14" CHD=S01°16'34"W R=770.00' L=65.45' 64.91' CHD=S06°07'38"W 65.44'
∆=3°41'46" R=1030.00' L=66.44' CHD=N14°20'36"W 66.43' °5 5 ∆ =1 8
∆=3°36'29" ∆=3°37'20" R=1030.00' R=1030.00' ∆=3°39'04" L=64.86' L=65.12' R=1030.00' CHD=N03°25'04"W CHD=N07°01'59"W L=65.64' 64.85' 65.11' CHD=N10°40'11"W 3 3 8 .5 9 ' N0 8 °4 0 '5 7 "W = D H 65.63' C ' 4 = 3 4 0 .1 0 .0 0 ' L 3 0 1 = '15 " R
8,956 SQ.FT. 0.205 AC.
0
3°
35.0'
LOT 232
S3
.2 79
S3
8,780 SQ.FT. 0.201 AC.
22,777 SQ.FT. 23,579 SQ.FT. 0.523 AC. 0.541 AC.
5' 173.0 "E 20' 30 N74°
N/F 800 PHILLIPS ROAD LLC 1580 SISTINE WAY T.A. # 065.02-4-52
∆=4°51'29" ∆=4°49'39" R=770.00' L=65.29' R=770.00' L=64.88' CHD=S03°33'12"E CHD=S08°23'47"E 65.27' 64.86'
∆ = 3 1 ° 1 2 ' 5 6 " R = 7 7 0 .0 0 ' L = 4 1 9 .5 1 ' C H D = S 0 2 ° 3 2 ' 0 6 "
10+00
346.62' N88° 17' 35"E
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-51
3
∆=4°56'49" R=770.00' L=66.48' CHD=S11°02'09"W 66.46'
356.84' N88° 17' 35"E
10+2
26,365 SQ.FT. 26,679 SQ.FT. 0.605 AC. 0.612 AC.
22,251 SQ.FT. 21,992 SQ.FT. 0.505 AC. 0.511 AC.
LOT 239
LOT 240
194.17' N88° 17' 35"E
∆=5°30'10" R=770.00' L=73.95' CHD=S15°49'27"W 73.92'
LOT 154
S88° 17' 35"W 199.33'
∆=5°03'59" R=770.00' L=68.09' CHD=S16°02'33"W 68.06'
24,653 SQ.FT. 0.566 AC. 25,690 SQ.FT. ∆=2°23'32" 0.589 AC. R=770.00' L=32.15' CHD=S16°56'48"E 32.15' ∆=1°57'05" R=1030.00' ∆=4°55'31" L=35.08' R=770.00' L=66.19' CHD=N17°10'02"W CHD=S13°17'17"E 35.08' 66.17'
LOT 243
LOT 237
LOT 238
LOT 241
LOT 244
26,239 SQ.FT.26,637 SQ.FT. 0.611 AC. 0.602 AC.
PROPOSED 20' STORM SEWER EASEMENT TO THE TOWN OF WEBSTER
LOT 242
LOT 245
LOT 246
LOT 151
371.38' N88° 17' 35"E
25,477 SQ.FT. 24,331 SQ.FT. 0.585 AC. 0.559 AC.
PROPOSED 20' STORM SEWER EASEMENT TO THE TOWN OF WEBSTER
20.0'
20.0'
LOT 247
N01° 42' 25"W 142.20'
S01° 42' 25"E 20.00'
N09° 12' 03"E 20.00'
LOT 118
BE (60 LLOR .0' WI A W A DE R.O Y .W .)
389.18' N88° 17' 35"E
N/F 800 PHILLIPS ROAD LLC 1594 BELLORA WAY T.A. # 065.02-4-18
402.46' N88° 17' 35"E
410.06' N88° 17' 35"E
412.15' N88° 17' 35"E
408.78' N88° 17' 35"E
401.35' N88° 28' 39"E
399.86' N88° 17' 35"E
S88° 28' 39"W 397.69'
385.20' N88° 17' 35"E
364.45' N88° 17' 35"E 364.45'
PROPOSED 20' WATERMAIN EASEMENT TO MONROE COUNTY WATER AUTHORITY
N01° 42' 25"W 20.00'
20,315 SQ.FT. 0.466 AC.
9'
0 3°
8"E
STREET
N56° 50' 52"E 20.00'
8'
.0' 20
S88° 19' 06"W 187.60'
142.83' LOT 231
PROPOSED 20' STORM SEWER EASEMENT TO THE TOWN OF WEBSTER
PROPOSED 20' STORM SEWER EASEMENT TO THE TOWN OF WEBSTER
149.26' S88° 19' 06"W 187.63'
60.0'
142.83'
PORTION OF EASEMENT TO BE ABANDONED IN THE RIGHT OF WAY
EXISTING SANITARY SEWER EASEMENT 10' WEST OF EX. SEWER TO R.O.W. TO TOWN OF WEBSTER PER LIBER 362 OF MAPS PAGE 44
TOWN OF WEBSTER
N88° 17' 35"E 15.00'
S01° 42' 25"E 141.99'
35' MAJOR HIGHWAY SETBACK TYP.
20.0'
141.98'
21+00
S01° 42' 25"E 1052.32'
64.82'
64.82'
N
ROAD
64.82'
64.82'
64.82'
60.00'
142.26'
67.35'
64.82'
T.P. 9164 (MCGS)
15.0'
64.82'
S01° 42' 25"E 1254.31' 64.82'
APPROXIMATE LOCATION 20' WIDE SANITARY SEWER EASEMENT TO THE TOWN OF WEBSTER PER LIBER 8299 PAGE 109
LOT 248
THE MEADOWS
SECTION 1
PROJECT LOCATION
N88° 17' 35"E 15.00'
N88° 19' 06"E 15.00'
APPROXIMATE LOCATION 20' WIDE SANITARY SEWER EASEMENT TO THE TOWN OF WEBSTER PER LIBER 8299 PAGE 109
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM & SANITARY SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
PHILLIPS
SALT ROAD
APPROXIMATE LOCATION 15' WIDE EASEMENT TO ROCHESTER GAS & ELECTRIC CORPORATION PER LIBER 4944 PAGE 33
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM & SANITARY SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
ROAD
ROAD
ROAD
(66' WIDE R.O.W.)
64.82'
64.82'
64.82'
64.82'
64.82'
SCHLEGEL
WALL
PROPOSED 15' FRONTAGE EASEMENT TO MONROE COUNTY WATER AUTHORITY
15.0'
N01° 42' 25"W 20.00'
N88° 17' 35"E 15.00'
SHALLOW CREEK TRAIL
PROPOSED 15' FRONTAGE EASEMENT TO MONROE COUNTY WATER AUTHORITY
COUNTY ROAD 6
N 1182249.59 E 815099.85 GRID
N/F 550 SALT ROAD LLC T.A. # 066.010-02-012.200 550 SALT ROAD LIBER 10933 PAGE 36
WEBSTER
N/F ROCHESTER GAS & ELECTRIC CORPORATION T.A.# 066.010-02-013.100WEB SALT ROAD
N/F THOMAS J. WIDELL II T.A. # 66.010-02-081 1705 SHALLOW CREEK TRAIL LIBER 11545 PAGE 567
N/F KRASUCKI PROPERTIES LLC T.A. # 066.010-02-012.110 560 SALT ROAD LIBER 10195 PAGE 440
20+00
N/F EDWARD A. & SUSAN. DUFFY T.A. # 66.010-02-046 1696 SHALLOW CREEK TRAIL LIBER 10097 PAGE 477
SCHLEGEL ROAD SCHOOL ENTRANCE
PROJECT DATA FRONT SETBACK
40 FT.
40 FT.
5 FT.
5 FT.
75%
19.8%
REQUIRED
PROPOSED
N/A
35 FT.
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-22
SITE LINE & SYMBOL LEGEND
LOT 122 EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM & SANITARY SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
SECTION/PARCEL BOUNDARY
3. ALL SITE WORK IS TO BE IN COMPLIANCE WITH THE STANDARDS OF THE TOWN OF WEBSTER. 4. PRESERVE ALL MATURE TREES ON SITE, WHERE POSSIBLE, AND MARK SAID TREES BY THE DEVELOPER'S ENGINEER PRIOR TO THE COMMENCING OF ANY SITE WORK. REAL PROPERTY TAX SERVICE:
APPROVALS 1.
THAT THE PROPOSED FACILITIES FOR WATER SUPPLY AND SEWAGE DISPOSAL ARE INSTALLED IN CONFORMITY WITH SAID PLANS ON FILE WITH THE MONROE COUNTY DEPARTMENT OF HEALTH.
MIN. BUILDING SETBACK
2.
THAT NO LOT OR REMAINING LAND (IF APPLICABLE) SHALL BE SUBDIVIDED WITHOUT PLANS, FOR SUCH RESUBDIVISION, BEING SUBMITTED TO AND APPROVED BY THE MONROE COUNTY DEPARTMENT OF HEALTH.
3.
THAT AN ORIGINAL SUBDIVISION MAP, AS APPROVED THIS DATE, SHALL BE FILED IN THE OFFICE OF THE CLERK OF THE COUNTY OF MONROE PRIOR TO OFFERING LOTS FOR SALE.
4.
THAT THE OWNER OF THE SUBDIVSION SHALL FURNISH EACH PURCHASER, OF A LOT, WITH A COPY OF THE APPROVED PLAN, OR IN THE CASE OF SALE OF DEVELOPED LOTS, THE OWNER OF THE SUBDIVISION SHALL FURNISH EACH PURCHASER WITH AN ACCURATE "AS-BUILT" PLAN DEPICTING ALL INSTALLED FAC- ILITIES INCLUDING SANITARY SEWAGE, STORM WATER AND WATER SUPPLY.
5.
THAT ADEQUATE EROSION/SILTATION CONTROL MEASURES SHALL BE EMPLOYED PRIOR TO AND DURING CONSTRUCTION. IF THE PROJECT WILL RESULT IN THE DISTURBANCE OF ONE ACRE OR MORE, COVERAGE UNDER THE NYSDEC SPEDES GP 0-15-002 FOR STORM WATER DISCHARGE FOR CONSTRUCTION ACTIVITIES WILL BE OBTAINED.
BY:
TOWN ENGINEER
EXIST. CONCRETE CURB EXIST. EDGE OF PAVEMENT
SURVEY NOTES
CENTER LINE
THE DEVELOPER'S AND CONTRACTOR'S ATTENTION IS DIRECTED TO LOCAL LAW NO. 6 OF 2019, REGARDING LIABILITY INCURRED THROUGH DISTURBANCE OR DESTRUCTION OF GEODETIC SURVEY MONUMENTS.
PROPOSED BUILDING
THE DEVELOPER AND CONTRACTOR MUST LOCATE, MARK, BARRICADE, SAFEGUARD AND PRESERVE ALL SURVEY CONTROL MONUMENTS AND RIGHT-OF-WAY MONUMENTS IN THE AREAS OF CONSTRUCTION. FOR DESCRIPTIVE AND SURVEY DATA FOR GEODETIC CONTROL MONUMENTS GO TO THE COUNTY OF MONROE SURVEYORS OFFICE WEBSITE AND ACCESS THE GIS BASED INTERNET WEB VIEWER, OR CONTACT THE MONROE COUNTY SURVEYORS OFFICE.
PROPOSED LOT LINE
PROPOSED CONCRETE CURB
BY:
PLANNING BOARD CHAIRPERSON
BY:
6.
TOWN HIGHWAY SUPERINTENDENT
TOPOGRAPHIC SURVEY WAS CONDUCTED ON MAY 11, 2023.
DATE:
2.
MAP ENTITLED "XEROX SUBDIVISION MAP" PREPARED BY BERGMANN ASSOCIATES DATED JUNE 10, 2008, HAVING PROJECT NUMBER 6912.10 AND IS FILED IN THE MONROE COUNTY CLERK'S AS LIBER 336 OF MAPS PAGE 41. THE DEEDS AS SHOWN ON FILE IN THE MONROE COUNTY CLERK'S OFFICE. BOOK 10731 OF DEEDS PAGE 75 (LOT 1 LIBER 336 MAPS, PAGE 41) MAP ENTITLED "BELLA TERRA SUBDIVISION SECTION 1" PREPARED BY COSTICH ENGINEERING DATED MARCH 13, 2020, HAVING PROJECT NUMBER 4500.10 AND IS FILED IN THE MONROE COUNTY CLERK'S AS LIBER 362 OF MAPS PAGE 43 AND 44.
Monroe County Surveyors Office BY:
BY
PUBLIC HEALTH ENGINEER
DATE
PROJECT MANAGER
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
GRAPHIC SCALE 40
0
20
80
40
T
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
160
( IN FEET ) 1 inch = 40 ft. NO.
DATE
REVISION
BY
CHKD.
APVLS.
EL
HI
C
TITLE OF PROJECT
W.T.A.
OF NEW Y E T.
Civil Engineering
DRAWN BY
W.T.A. J.S.F. TOPO/BASE
L. S. 49 N O. 0 5 0 4 S V ED UR L AND S
Landscape Architecture
G.L.R.
PLAT MAP SECTION 2B PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
1"=40'
BELLA TERRA SUBDIVISION SECTION 2
TITLE OF DRAWING
Land Surveying
BOUNDARY
R
1.
EASEMENT DIMENSION
I
REFERENCES
XX.XX'
Daniel T. Hickok, N.Y.S. L.S., No. 050449
FIRE MARSHAL
3.
8.
BY:
YO
ELEVATIONS ARE REFERENCED TO MONUMENT 1128-3 (NYGS) 1940 & 1972, REFERENCED TO THE NATIONAL GEODETIC VERTICAL DATUM OF 1929, (ELEV.=353.736)
DIRECTOR OF PUBLIC HEALTH
EXIST. EDGE OF PAVEMENT EXISTING UTILITY POLE, GUY ANCHOR & POLE W/LIGHT
THAT THIS MAP WAS PREPARED FROM NOTES OF AN INSTRUMENT SURVEY COMPLETED ON MAY 11, 2023 AND FROM THE REFERENCE(S) LISTED HEREON. NO SEARCH OF RECORDS, OTHER THAN THOSE REFERENCED, WAS MADE FOR EASEMENTS OR ENCUMBRANCES AFFECTING THIS PARCEL.
County Highway Superintendent For the Monroe County Monumentation Law
E
7.
TOWN ASSESSOR
EN
ALL DISTANCES SHOWN ON THIS MAP ARE REFERENCED TO THE GROUND.
BY:
LI C
6.
This plat is approved in accordance with the provisions of Section 239-F, Article 12-B of the General Municipal Law and/or the Monroe County Monumentation Law. A separate approval is required for site construction. For the General Municipal Law:
K
USING A COMBINED SEA LEVEL AND COMBINED FACTOR OF 1.0000329, TIES TO MONUMENTATION WAS MADE USING APPROPRIATE PROCEDURES TO OBTAIN AN INDICATED ACCURACY OF 1:20,000 OR BETTER.
911 APPROVAL:
REALTY SUBDIVISION APPROVAL THIS IS TO CERTIFY THAT APPROVED PLANS FOR WATER SUPPLY AND SEWAGE DISPOSAL FOR THIS PROJECT ARE ON FILE IN THE OFFICE OF THE MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH. CONSENT IS HEREBY GIVEN FOR THE FILING OF THIS MAP IN THE MONROE COUNTY CLERK'S OFFICE IN ACCORDANCE WITH ARTICLE III OF THE MONROE COUNTY SANITARY CODE
RK O OK
5.
EXIST. RIGHT-OF-WAY LINE
THE HORIZONTAL DATUM SHOWN HEREON IS REFERENCED TO THE NEW YORK STATE PLANE COORDINATE SYSTEM OF 1927, WEST ZONE, TRANSVERSE MERCATOR PROJECTION, NAD 27 THROUGH CONTROL TIES TO THE FOLLOWING GEODETIC MONUMENTS N=1,182,944.36 E=811,944.70 (NAD 1927) N=1,182,986.24 E=814,040.05 (NAD 1927)
WEBSTER SEWER DISTRICT
-
MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH MONROE COUNTY SURVEYORS OFFICE:
EXIST. EASEMENT LINE
THIS PROJECT IS LESS THAN 5000 FEET FROM THE NEAREST GEODETIC SURVEY MONUMENT AND THIS PROJECT IS TIED INTO THE MONROE COUNTY GEODETIC MONUMENTATION NETWORK
1139-5 (NYGS) 1940/1982 1139-4 (NYGS) 1940/1982
BY:
WE, COSTICH ENGINEERING, D.P.C., HEREBY CERTIFY T0
A
4.
EXIST. ADJOINING PROPERTY LINE
CERTIFICATION
N
3.
PROPOSED EASEMENT LINE
THAT PLAN APPROVAL IS LIMITED TO 5 YEARS. TIME EXTENSIONS FOR PLAN APPROVAL MAY BE GRANTED BY THE MONROE COUNTY DEPARTMENT OF HEALTH BASED UPON DEVELOPMENTAL FACTS AND THE REALITY SUBDIVISION REGULATIONS IN EFFECT AT THAT TIME. A NEW PLAN SUBMISSION MAY BE REQUIRED TO OBTAIN A TIME EXTENSION.
6. THE DEED RESTRICTIONS FOR THE PROPERTY SHALL INCORPORATE THE DEFINITION OF THE PROPERTY LIMITS AND THE CONDITION OF DISTURBANCE BEYOND THE PROPERTY LIMITS.
ST
2.
5. COMPLY WITH ALL REQUIREMENTS OF ANY FEDERAL, STATE, COUNTY OR TOWN AGENCY.
MONROE COUNTY DEPARTMENT OF HEALTH REALTY SUBDIVISION CONDITIONS OF APPROVAL :
ADJACENT PROPERTY LINE
CENTER LINE
TRAIL MILANO
# 065.02-4-57
800 PHILLIPS ROAD LLC
2. ALL ROADWAY CONSTRUCTION TO BE IN ACCORDANCE WITH THE SPECIFICATIONS AND REGULATIONS SET FORTH BY THE TOWN OF WEBSTER.
RIGHT-OF-WAY LINE
LOT 156
1.
1. ALL THE IMPROVEMENTS SHALL BE CONSTRUCTED ACCORDING TO THE SPECIFICATIONS OF THE TOWN OF WEBSTER.
DA
N/F 800 PHILLIPS ROAD LLC 1572 SISTINE WAY T.A. # 065.02-4-56
131 Change to Costich Style
SPECIAL NOTES
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA101
SHEET 2 OF 9
D
W
RIM= 366.92
S
N
D
TG=363.26
W
36 APPROXIMATE LOCATION OF EXISTING 8" DIP CLASS 52 WATER MAIN
LOT 203
LOT 204
W
70'-18" HDPE @ 0.91%
LOT 205
PROPOSED 1" COPPER WATER SERVICE TO THE CURB STOP. 1" PE PRIVATE SERVICE TO THE BUILDING
LOT 208
LOT 207
LOT 206
DC-4 2'x2' INLET TG=361.0
DC-5 END SECTION INV=360.65
126'-24" HDPE @ 0.24% (PERF.)
361.33 361.23
360.65
357.90
OH
OH
W
35
0.8 0%
OH
16 1'24 "H
E
E
E
E
E
OH
RGE 102
OH
OH
OH
OH
OH
OH
OH OH
OH
OH
E
OH
OH
E
APPROXIMATE LOCATION TOWN LOT 7 OH
6.2
1
RGE 100 RGE T168
OH
OH
OH
35
@ "H DP E
MEADOWS TWO SUBDIVISION
TOWN OF WEBSTER OPEN SPACE
REMOVE BLOW OFF AND CONNECT TO EXISTING 8" D.I.P.
W
1. 1
6
8" D
10
0'24
2" BLOW OFF
OW
35
351.16
D
31 0.
38'-24" HDPE @ 0.81%
ARR
D-9 5' DIA M.H. RIM=0.0
"H DP 17 E @ 7'8" 0.9 PV 2% C @ 0.8 5%
18
FUTURE SECTIONS MEADOWS TWO SUBDIVISION
W
00 0. 35
LOT 120
ING
APPROXIMATE LOCATION TOWN LOT 14 35
107'-24" HDPE @ 0.80%
350.31
LOT 121
(60.
E
D-8 5' DIA M.H. RIM=0.0 D
LOT 122
LOT 123
APPROXIMATE LOCATION TOWN LOT 12
E
D-7 END SECTION INV=350.00
LOT 124
D-12 5' DIA M.H. RIM=360.9
APPROXIMATE LOCATION TOWN LOT 14
E
0. 8
LOT 125 D-11 5' DIA M.H. RIM=360.9
D
AIN
E
0%
LOT 126
356.21
273'-24" HDPE @ 0.80%
ATE RM
E
LOT 127
354.02
REMAINING LANDS SALT ROAD (ZONED: LMR)
IP W
E
9
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
15+71
0' W OOD IDE T R.O RAIL .W. EXI ST )
E
1.
D
APPROXIMATE LOCATION TOWN LOT 12
APPROXIMATE LOCATION TOWN LOT 6
W
E
MW MW
E OH
MW
DP E@
OH
E
OH
W OH
E
E
OH
14
DD-1 2'x2' INLET TG=367.3
OH
E
RGE T167A
23'-12" HDPE @ 1.02%
72'-12" HDPE @ 0.81%
E
OH
PROVIDE 18" MIN. SERERATION
E
35
6D
354.02
5'-
DD3 2'x2' INLET TG=365.0
23'-12" HDPE @ 1.03%
DD END SECTION INV=360.65
.5'
258'-24" HDPE @ 0.80%
351.96
18
361.56
E
D-10 5' DIA M.H. RIM=352.0
1
361.66 361.90
16+00
RGE 101
N/F XEROX CORPORATION T.A. # 65.020-01-040.110 750 PHILLIPS ROAD
DD-2 2'x2' INLET TG=367.6
E
14.5' SEPARATION FROM UTILITY POLE
9
8" ZINC COATED D.I.P. WATERMAIN
E
S00° 55' 15"E 726.83'
1.2
LOT 209
7.5
0
357.60
DC-10.1 END SECTION INV=368.00
LOT 210
17+00
OH
OH
DC-3 5' DIA INLET M.H. TG=365.8
4.6
W
69'-8" PVC @ 0.68%
RGE T172
DC-6A 5' DIA M.H. RIM=365.1
LOT 131
LOT 132
PROVIDE 18" MIN. SERERATION
356.00
S-1.5 4' DIA M.H. RIM=365.1
LOT 211
RGE 103 RGE T171
S-1.6 4' DIA M.H. RIM=366.1
SA
W
3
LOT 201
N/F 800 PHILLIPS ROAD LLC 535 TERRA VERDE WAY T.A. # 065.02-4-31
SA
W
H
WV
Y D
358.3
356.06
LOT 202
4'X10' BOX CULVERT IN COMPLIANCE WITH PREVIOUSLY APPROVED USACE PERMIT SEE SHEET CA300
ST
SA ST
ARROWWOOD TRAIL
WV TG=361.85
TG=361.67
S-1.4: CONNECT TO EX. STRUCTURE INV=353.32 INV=353.42
SA
(60.0' WIDE R.O.W.)
ST
S-1.7 4' DIA M.H. RIM=368.1
ST SA SA ST
36
4 359.5
SA ST
S-1.8 4' DIA M.H. RIM=368.5
CS
CS
CS
163'-24" HDPE @ 0.21%
W
350.82 8" PVC
S RGE T166
OH OH
CS
353.88
ST
23'-12" HDPE @ 1.09% DC-8.1 2'x2' INLET TG=368.2 10'-12" HDPE @ 0.80%
358.81
CS
W
TG=361.14
350.92
S
RIM=362.87
OH OH OH OH
D
8" PVC STUB INV=353.42
S 356.10
361.00
CS
8" PVC @ 1.01%
PROPOSED 6" SDR-21 STORM LATERAL TYP.
OH
S
263'-8" PVC @ 0.82%
361.60 D 361.10
102'-8" PVC @ 1.99%
353.98
358.7
S 9
OH
@ 0.40%
CS
D
OH
D 362.00
3% 264'-24" HDPE @ 0.4
ST
LOT 212
OH
114'-8" PVC
6'-12" HDPE @ 1.00% 88'-12" HDPE @ 0.46%
362.96
362.33 D 358.32 362.23 S 358.27
SA
1
6
0 363.
S-1.9 4' DIA M.H. RIM=370.1
CS
OH
358.98 D
33
SA
7 35
(60.0' W
"P 55'-8
.85%
0 VC @
E
D 358.
ERDE WAY TERRA VID E R.O.W.)
4+00
1
@
E
ST
6 .3
5+00
DPE
8" H 54'-1
% 0.52
E
SA ST
S
3+00
6+00
SA
ST
%
CS
PROPOSED 4" SDR-21 SANITARY LATERAL TYP.
N/F 800 PHILLIPS ROAD LLC 531 TERRA VERDE WAY T.A. # 065.02-4-32
353.32
2+00
RIM=364.08
DC-6 5' DIA M.H. RIM=365.8
22'-12" HDPE @ 1.00%
W
W
W
W
ST SA
CS
S 86 363. 14 360.
W
7+00
LOT 213
CS
20 1.
RIM=362.30 N. INV=349.88 8" PVC E. INV=349.93 8" PVC S. INV=351.58 8" PVC
358.23 RIM=364.02
W
7 35
DC-8 5' DIA M.H. RIM=368.4
W
W
0.7
@
CS
LOT 133
LOT 134
DA-5.2 5' DIA M.H. RIM=364.2
CS
CS
D
6 3.9 36 .16 0 36
"
'-8
4 11
9%
S-1.10 4' DIA M.H. RIM=371.1
E DP "H
S
356.20 D RIM=362.14
7 .4
W
W
11
@
C PV
.06
12
356.01
∆=5°16'19" R=1500.00' L=138.02' 12" HDPE @ 1.09% CHD=N02°32'31"E 137.97'
W
W
DC-6.1 2'x2' INLET TG=365.3
W
CS
CS CS
8"
1 2'-
00 8+
18+00
N/F 800 PHILLIPS ROAD LLC 525 TERRA VERDE WAY T.A. # 065.02-4-33
TG= 361.39
DC-6.2 2'x2' INLET TG=365.3
CS
P. C. STA 1+38.02
1+00
36" HDPE
8" PVC
W
ST SA
ST SA
W
HD
LOT 214
D S
1 36
0
@
REMAINDER OF LI
ST
1'-
W
0+00
60' R.O.W.
ST SA
65'-12" HDPE @ 1.00%
SA ST
SA ST
9 4.5 36
PE
CS
18+91
(60.0' WIDE R.O.W.)
8" ZINC COATED D.I.P. WATERMAIN
ST SA
DC-9 5' DIA M.H. RIM=370.0 SA ST
SA ST
CS
% .57
SA
CS
20
W
PROPOSED HYDRANT
DC-7 5' DIA M.H. RIM=368.1
00
9+
W
DC-8.2 2'x2' INLET TG=368.2
PROPOSED 8" TEE AND GATE VALVE
CS
TERRA VERDE WAY
TERRA VERDE WAY
N/F 800 PHILLIPS ROAD LLC 521 TERRA VERDE WAY T.A. # 065.02-4-34
2" BLOW OFF
LOT 222
PROPOSED HYDRANT APRON (SEE DETAIL)
W
57
REMOVE BLOW OFF AND CONNECT TO EXISTING 8" D.I.P. DA-5.1: CONNECT TO EX. STRUCTURE INV=358.23 INV=358.33
LOT 223
LOT 221
DC-10 5' DIA M.H. RIM=371.0
PROPOSED 4" SDR-21 SANITARY LATERAL TYP.
ST SA
5.
W
W
W
W
EXISTING 8" DIP WATER MAIN W W
LOT 224
LOT 130
LOT 166
W
LOT 219
LOT 220 N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-30
LOT 218
ST
PROPOSED 6" SDR-21 STORM LATERAL TYP.
CS
SA
LOT 217
36
W
W
LOT 129
7% @ 0.7 DPE 12" H
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-66
36 2. 7 1
W RIM=362.87
D 36" HDPE
PROVIDE 5' MIN. COVER OVER WATER MAIN AT DITCH CROSSING
36
LOT 135
0
360.76
TG=363.95
12" HDPE
TG=363.65
36" HDPE
8" PVC 357.72
357.72
OH
N/F 800 PHILLIPS ROAD LLC 1553 SISTINE WAY T.A. # 065.02-4-29
SA
CS
DC10.1 PROPOSED HYDRANT 2'x2' INLET APRON (SEE DETAIL) TG=370.4 LOT 216 DC-10.2 2'x2' INLET TG=370.4 23'-12" HDPE @ 1.82% 8'-12" HDPE @ 1.00% ST CS
D1 END SECTION INV=357.47
ST
10+00
LOT 215
SA
N/F 800 PHILLIPS ROAD LLC 1551 BELLORA WAY T.A. # 065.02-4-35
6.4
S D RIM=364.18 358.75
361.22
RIM=367.10
RIM=364.66
359.31
TG=364.02
358.83
356.76
352.01 RIM=364.66
OH OH RGE 97/ T165
OH
LOT 128
PROPOSED 1" COPPER WATER SERVICE TO THE CURB STOP. 1" PE PRIVATE SERVICE TO THE BUILDING
SA
OH
LOT 165
LOT 136
PROPOSED HYDRANT
INSTALL LATERALS FOR FUCTURE SECTION UNDER PROPOSED ROAD.
ST SA
CS
ST
N/F 800 PHILLIPS ROAD LLC 1555 SISTINE WAY T.A. # 065.02-4-28
S-1.11 4' DIA M.H. RIM=372.1
S
OH
N/F 800 PHILLIPS ROAD LLC 1554 SISTINE WAY T.A. # 065.02-4-65
D
OH
LOT 164
N/F 800 PHILLIPS ROAD LLC 1553 BELLORA WAY T.A. # 065.02-4-36
PROPOSED 8" GATE VALVE
E
LOT 137
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 1556 SISTINE WAY T.A. # 065.02-4-64
DC-11 5' DIA M.H. RIM=372.1
ST SA
E
N/F 800 PHILLIPS ROAD LLC 1555 BELLORA WAY T.A. # 065.02-4-37
END OF PROPOSED WATER MAIN, PROVIDE (2) LENGTHS OF PIPE PAST THE PROPOSED GATE VALVE, PROVIDE A TAPPED TEE WITH 2" BLOW-OFF AND USE BLOW-OFF AS TEMPORARY SAMPLING TAP.
LOT 127
E
BELLA TERRA SECTION 1
10+96
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-27
OH
LOT 163
E
LOT 138
MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH
EXISTING MEADOWS TWO BIO-RETENTION
EXISTING MEADOWS TWO SMF
OH
N/F 800 PHILLIPS ROAD LLC 1558 SISTINE WAY T.A. # 065.02-4-63
REMAINING LANDS SALT ROAD (ZONED: LMR)
E
351.93
.) (60.0' WIDE R.O.W
E
N/F 800 PHILLIPS ROAD LLC 1557 BELLORA WAY T.A. # 065.02-4-38
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
E
OH
RT CARBELLA COU
E
24" HDPE
LOT 162
24" CMP N.INV=363.22 S.INV=363.35
359.36
LOT 139
8" PVC
N/F 800 PHILLIPS ROAD LLC 1560 SISTINE WAY T.A. # 065.02-4-62
24" HDPE
N/F 800 PHILLIPS ROAD LLC 1559 BELLORA WAY T.A. # 065.02-4-39
LOT 126
360.89
OH
800 PHILLIPS ROAD LLC T.A. # 065.02-4-26
358.30
LOT 140
GRID
LOT 161
800 PHILLIPS ROAD LLC 1561 BELLORA WAY T.A. # 065.02-4-40
W
THESE PLANS FOR PUBLIC SANITARY SEWER EXTENSION / IMPROVEMENTS ARE HEREBY APPROVED PURSUANT TO ARTICLE 17 OF THE NYS ENVIROMENTAL CONSERVATION LAW SUBJECT TO CONDITIONS OF APPROVAL
DIRECTOR OF PUBLIC HEALTH
WATER MAINS AND APPURTENANCES TO BE CONSTRUCTED IN ACCORDANCE WITH THE REGULATIONS AND SPECIFICATIONS OF THE WATER AUTHORITY:
2.
LOT LINE
4" DIA. STORM DRAIN BEYOND CELLAR EXCAVATION
WHERE WATER SERVICE CROSSES STORM AND/OR SANITARY SEWER MAINS OR LATERALS, AN 18" MIN. SEPARATION IS REQUIRED.
GAR.
HOUSE 4" DIA.
DRIVEWAY
CLEAN OUT 10' MIN.
PE WATER SERVICE FROM THE CURB BOX TO THE HOUSE 6" DIA. STM LATERAL
LATERALS AND SERVICES TO EXTEND 11' PAST THE R.O.W. LINE OR 11' PAST A PERMANENT EASEMENT LINE, WHICHEVER IS GREATER.
4" DIA. SAN. LATERAL
FOR SETBACK INFO, SEE PLAT MAP FOR INDIVIDUAL LOT SPECIFICATIONS.
CURB BOX FOR THE WATER SERVICE ON R.O.W. LINE R.O.W. LINE
11'
·
1.
COPPER WATER SERVICE FROM THE WATERMAIN TO THE CURB BOX.
4.
5.
3. WHEN INSTALLING FIRE HYDRANTS, SHOULD GROUND WATER BE ENCOUNTERED WITHIN SEVEN (7) FEET OF THE FINISHED GRADE, FIRE HYDRANT WEEP HOLES (DRAINS) SHALL BE PLUGGED.
SECTION/PARCEL BOUNDARY PROPOSED RIGHT-OF-WAY PROPOSED LOT LINE PROPOSED EASEMENT LINE MIN. BUILDING SETBACK CENTER LINE EXIST. ADJOINING PROPERTY LINE EXIST. EASEMENT LINE EXIST. RIGHT-OF-WAY LINE EXIST. EDGE OF PAVEMENT
4. THE WATER MAIN SHALL BE PRESSURE/LEAKAGE TESTED IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE AWWA STANDARD C600 (LATEST REVISION) OR IN ACCORDANCE WITH
TOWN DRIVEWAY NOTES
THE CONTRACTOR SHALL LOCATE, MARK, SAFEGUARD AND PRESERVE ALL SURVEY CONTROL MONUMENTS AND RIGHT-OF-WAY MONUMENTS IN THE AREA OF THE SITE CONSTRUCTION, FOR DESCRIPTIVE AND SURVEY DATA PERTAINING TO THE MONUMENTS, CALL THE MONROE COUNTY GEODETIC SURVEY OFFICE. ALL SANITARY SEWERS, STORM SEWERS, WATER MAINS, AND APPURTENANCES, NOT WITHIN A DEDICATED RIGHT-OF-WAY, SHALL BE DEDICATED TO THE PROPER, GOVERNING AGENCY. THE DEDICATION SHALL BE CONDUCTED THROUGH EASEMENTS, WHICH SHALL BE SHOWN AND DESCRIBED AT THE FINAL STAGE OF PLANS.
1.
DRIVEWAYS ARE NOT PERMITTED OVER MANHOLES, CLEAN-OUTS, VALVES AND CATCH BASINS.
2.
DRIVEWAY CONNECTIONS ARE NOT PERMITTED IN THE VICINITY OF RECEIVING BASINS AND/OR THE TEMPORARY TURNAROUND.
3.
DRIVEWAY CONNECTIONS ARE NOT ALLOWED WITHIN 10' OF A HYDRANT.
DRIVEWAYS ARE NOT PERMITTED OVER MANHOLES, CLEAN-OUTS, VALVES AND CATCH BASINS
EXIST. WATER MAIN, GATE VALVE & HYDRANT EXIST. SANITARY SEWER & MANHOLE
W
4.
DRIVEWAYS TO HAVE 5 FOOT MINIMUM SEPARATION.
STORM SEWER LATERALS, FOR SINGLE-FAMILY HOMES ARE TO BE 6" DIA. P.V.C., SDR-35, AND ARE TO EXTEND (11) ELEVEN FEET BEYOND THE RIGHT-OF-WAY LINE OR (11) ELEVEN FEET BEYOND AN EASEMENT LINE (WHICHEVER IS GREATER).
1. 2.
DATE:
LEGEND BY:
ALL CROSSOVER PIPES SHALL BE PERFORATED HDPE.
W
Y
PROP. WATER MAIN, GATE VALVE & HYDRANT PROP. SANITARY SEWER & MANHOLE
PLANNING BOARD CHAIRPERSON
BY:
TOWN HIGHWAY SUPERINTENDENT
BY:
WEBSTER SEWER DISTRICT
BY:
TOWN ASSESSOR
EXIST. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION BY:
FIRE MARSHAL
PROP. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION
ALL ROADWAY WEEPS SHALL HAVE UNDERDRAIN THE FULL LENGTH OF THE ROAD.
PROP. GUTTER AND CATCH BASIN
BY:
MONROE COUNTY WATER AUTHORITY
2.
3.
4.
5.
ROOF LEADERS SHALL BE CONNECTED TO THE STORM SEWER DRAINAGE SYSTEM VIA A 6" PIPE WITH CLEANOUTS. FOUNDATION DRAINS SHALL BE CONNECTED TO THE STORM SEWER LATERALS VIA A SUMP PUMP. STORM SEWER PIPE MATERIAL OPTIONS ARE AS FOLLOWS: a) POLYVINYL CHLORIDE (P.V.C.) SDR-35. b) CORRUGATED POLYETHYLENE HIGH DENSITY PLASTIC (C.P.P.) ALL STORM PIPE CONNECTIONS TO BE WATER TIGHT.
PROJECT MANAGER
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
GRAPHIC SCALE 40
0
20
80
40
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
160
( IN FEET ) 1 inch = 40 ft. NO.
DATE
REVISION
BY
CHKD.
APVLS.
TE EL O R I T Y
DRAWN BY
BOUNDARY
C
HA
PR
0 9 6 1 84
OFE
SS I O N
TITLE OF PROJECT
W.T.A.
OF NEW
ED
NOT TO SCALE
SANITARY SEWER LATERALS, FOR THE SINGLE-FAMILY HOMES, ARE TO BE 4" DIA. P.V.C., SDR-21 OR SCH 40, AND SHALL EXTEND ELEVEN (11) FEET BEYOND THE RIGHT-OF-WAY LINE OR(11) ELEVEN FEET BEYOND AN EASEMENT LINE. (WHICHEVER IS GREATER)
DATE
TOWN ENGINEER
NS
TYPICAL LATERAL LAYOUT DETAIL
5.
BY:
L I CE
WATERMAIN CROSSING IS SUBJECT TO M.C.H.D. REGULATIONS
8" MIN. DIA. WATERMAIN
SANITARY SEWER MAINS ARE TO BE POLYVINYL CHLORIDE (P.V.C.), SDR-35, UNLESS DEPTHS EXCEED 12' IN WHICH CASE USE SDR-21.
PUBLIC HEALTH ENGINEER
APPROVALS
RK O IE
R.O.W. LINE HYDRANT IN LINE WITH PROPERTY LINE BOUNDARY
W
4.
THE PRESSURE AND FLOW DATA PROVIDED HEREIN REPRESENTS THE CALCULATED VALUES FOR THIS LOCATION IN THE DISTRIBUTION SYSTEM BASED ON TYPICAL LOW OPERATING CONDITIONS. THESE VALUES CAN VARY DEPENDING ON DEMANDS, OPERATIONAL PARAMETERS, SYSTEM CONFIGURATIONS, SUBSEQUENT MODIFICATIONS AND OTHER RELATED CRITERIA. PLEASE CONTACT MONROE COUNTY WATER AUTHORITY WITH ANY ADDITIONAL QUESTIONS.
H
W
MANHOLES ARE NOT TO CONFLICT WITH DRIVEWAY
THE DEVELOPERS AND CONTRACTORS ATTENTION IS DIRECTED TO LOCAL LAW NO. 6 OF 1971, REGARDING LIABILITY INCURRED THROUGH THROUGH DISTURBANCE OR DESTRUCTION OF GEODETIC SURVEY MONUMENTS, THE CONTRACTOR SHALL LOCATE, MARK, SAFEGUARD AND PRESERVE ALL SURVEY CONTROL MONUMENTS AND RIGHT-OF-WAY MONUMENTS IN THE AREA OF CONSTRUCTION. FOR MORE DESCRIPTIVE AND SURVEY DATA ON CONTROL MONUMENTS, CALL THE MONROE COUNTY GEODETIC SURVEY OFFICE.
STORM SEWER NOTES
SANITARY SEWER STORM SEWER WYE
ROAD CENTERLINE
·
3.
2. MINIMUM VERTICAL SEPARATION BETWEEN WATER MAINS AND SEWER PIPES SHALL BE 18 INCHES MEASURED FROM THE OUTSIDE OF THE PIPES AT THE POINT OF CROSSING. ONE FULL STANDARD LAYING LENGTH OF WATER MAIN SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. IN ADDITION, WHEN THE WATER MAIN PASSES UNDER A SEWER, ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECT FILL), SHALL BE PROVIDED FOR THE SEWER TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING OF THE SEWER ON THE WATER MAIN. MINIMUM HORIZONTAL SEPARATION BETWEEN PARALLEL WATER MAINS AND SEWER PIPES (INCLUDING MANHOLES AND VAULTS) SHALL BE 10 FEET MEASURED FROM THE OUTSIDE OF THE PIPES, MANHOLES OR VAULTS.
BY
PLEASE NOTE THE FOLLOWING INFORMATION
H
CLEANOUT(S), ON R.O.W. LINE OR EASEMENT LINE; EXTEND LATERAL 11' PAST CLEAN OUT. PROVIDE BRASS CAP.
·
ALL IMPROVEMENTS SHALL BE DONE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE TOWN OF WEBSTER, THE MONROE COUNTY HEALTH DEPARTMENT, THE MONROE COUNTY WATER AUTHORITY, THE MONROE COUNTY DEPARTMENT OF TRANSPORTATION, AND ANY OTHER AGENCY HAVING JURISDICTION.
DIRECTOR OF PUBLIC HEALTH
ER
NOTES:
WATER MAINS AND ALL WATER SERVICE LINES SHALL HAVE A MINIMUM OF FIVE FEET OF COVER FROM FINISHED GRADE IN LAWN AREAS AND A MINIMUM OF SIX FEET OF COVER FROM FINISHED GRADE IN PAVED AREAS. MINIMUM VERTICAL SEPARATION BETWEEN WATER MAIN AND SEWER MAINS SHALL BE 18" MEASURED FROM OUTSIDE OF PIPES AT THE POINT OF CROSSING. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER MAINS AND SEWER MAINS SHALL BE TEN FEET MEASURED FROM OUTSIDE OF THE PIPES. ONE FULL LENGTH OF WATER MAIN SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. WHERE A WATER MAIN CROSSES UNDER A SEWER ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECTED FILL) SHALL BE PROVIDED FOR THE SEWERS TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING ON AND BREAKING THE WATER MAINS. FIRE HYDRANT WEEP HOLES (DRAINS) SHALL BE PLUGGED WHEN GROUND WATER IS ENCOUNTERED WITHIN SEVEN FEET OF THE FINISHED GRADE. ALL MECHANICAL JOINT FITTINGS (TEES, BENDS, PLUGS, ETC.) SHALL BE BACKED WITH 2500 PSI CONCRETE THRUST BLOCKS OF APPROPRIATE SIZE TO PROVIDE THRUST RESTRAINT. SEPT 2017
2.
DATE
THESE PLANS FOR PUBLIC WATER SYSTEM EXTENSION / IMPROVEMENT ARE HEREBY APPROVED PURSUANT TO 10NYCRR5 OF THE STATE SANITARY CODE SUBJECT TO CONDITIONS OF APPROVAL
I NE
·
GUTTER INLET
LOT LINE
FLOOR DRAINS, IF CONSTRUCTED IN THE PROJECT, MUST BE CONNECTED TO THE SANITARY SEWER. NOTE: FLOOR DRAINS DO NOT INCLUDE FOUNDATION OR FOOTER DRAINS INSTALLED TO INTERCEPT UNCONTAMINATED GROUND WATER. ALL DISCHARGES FROM THE FLOOR DRAINS TO THE SANITARY SEWER MUST COMPLY WITH THE EFFLUENT LIMITS OF THE LOCAL AND/OR THE MONROE COUNTY SEWER USE LAW.
DATA SUPPLIED BY THE MCWA LOCATION: TERRA VERDE WAY TEST DATE: 5/26/2023 STATIC PRESSURE = 55 PSI OBSERVED FLOW = 1067 GPM RESIDUAL PRESSURE = 44 PSI Q20= 1993 GPM
NG
·
3.
PUBLIC HEALTH ENGINEER
MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH
E
·
DEFLECTION TESTS SHALL BE PERFORMED ON ALL FLEXIBLE PIPE. THE TEST SHALL BE CONDUCTED AFTER THE FINAL BACKFILL HAS BEEN IN PLACE AT LEAST THIRTY DAYS. NO PIPE SHALL EXCEED A DEFLECTION OF 5%. IF THE DEFLECTION TEST IS TO BE RUN USING A RIGID BALL OR MANDREL, IT SHALL HAVE A DIAMETER EQUAL TO 95% OF THE INSIDE DIAMETER OF THE PIPE, THE TEST SHALL BE PERFORMED WITHOUT THE AID OF MECHANICAL PULLING DEVICES.
HYDRANT FLOW TEST DATA
A
·
SOIL TEST. THE CONTRACTOR SHALL PROVIDE A SOIL TEST EVALUATION TO DETERMINE THE NEED FOR POLYETHYLENE ENCASEMENT PER ANSI/AWWS C105/AZ1.5-82 PRIOR TO WATER MAIN INSTALLATION. SOIL TESTING SHALL BE CONDUCTED BY AN APPROVED SOIL TESTING LABORATORY IN ACCORDANCE WITH WATER AUTHORITY STANDARDS. PRESSURE TEST. WATER MAINS TO BE PRESSURE TESTED IN ACCORDANCE WITH THE LATEST WATER AUTHORITY SPECIFICATIONS. A WATER AUTHORITY REPRESENTATIVE MUST WITNESS THIS TEST. HEALTH SAMPLE. THE WATER MAIN SHALL BE DISINFECTION EQUAL TO AWWA STANDARD SPECIFICATIONS, DESIGNATION C-651, BY USING THE CONTINUOUS FEED METHOD. AFTER FLUSHING AND DISINFECTING THE WATER MAIN, WATER SAMPLES SHALL BE COLLECTED FROM THE MAIN BY THE MONROE COUNTY HEALTH DEPARTMENT. FIRE HYDRANTS ARE NOT ACCEPTABLE SAMPLING POINTS. APPROVAL AND NOTIFICATION BY THE HEALTH DEPARTMENT MUST BE RECEIVED BEFORE THE MAIN IS PLACED IN SERVICE.
1. THE WATER MAIN SHALL BE DISINFECTED EQUAL TO A.W.W.A. STANDARD FOR "DISINFECTING OF WATER MAINS, DESIGNATION C651" (LATEST REVISION). FOLLOWING DISINFECTION, THE WATERMAIN SHALL BE FLUSHED UNTIL THE CHLORINE CONCENTRATION, IN THE WATER LEAVING THE MAIN, IS NO HIGHER THAN THAT GENERALLY PREVAILING IN THE SYSTEM. ALL WATER MAIN FITTINGS NOT RECEIVING 24-HOUR CHLORINE DISINFECTION CONTACT TIME MUST BE SWAB DISINFECTED 30 MINUTES PRIOR TO INSTALLATION. THE SAMPLING POINT(s) MUST BE DECONTAMINATED BY FLAMING. FIRE HYDRANTS ARE NOT ACCEPTABLE SAMPLING POINTS. THE MONROE COUNTY DEPARTMENT OF HEALTH MUST RECEIVE AT LEAST 48-HOUR ADVANCE NOTIFICATION REQUESTING SAMPLING SERVICES. SAMPLING WILL NOT BE PERFORMED PRIOR TO RECEIPT FROM A NEW YORK STATE LICENSED OR REGISTERED DESIGN PROFESSIONAL (ENGINEER, ARCHITECT OR LAND SURVEYOR WITH A SPECIAL EXEMPTION UNDER SECTION 7208(n) OF THE EDUCATION LAW) CERTIFYING THAT THE WATER SUPPLY IMPROVEMENTS, TESTING AND DISINFECTION PROCEDURES WERE COMPLETED IN ACCORDANCE WITH THE APPROVED PLANS, REPORTS, SPECIFICATIONS AND ANY APPROVED AMENDMENTS. THE DEPARTMENT WILL COLLECT SAMPLES FOR FREE CHLORINE RESIDUAL, TOTAL COLIFORM, ESCHERICHIA COLI (E. COLI) AND TURBIDITY. THE WATER MAIN SHALL NOT BE PLACED INTO SERVICE UNTIL SO AUTHORIZED BY THE MONROE COUNTY DEPARTMENT OF HEALTH.
C
·
BY
EXISTING UTILITIES (LOCATIONS, SIZES, MATERIALS & INVERTS) SHOWN ON THE PLANS, HAVE BEEN PLOTTED FROM FIELD SURVEYS AND RECORD MAPS AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION AND/OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF OR CLOSELY PARALLEL TO, OR UNDER THE PROPOSED CON-STRUCTION, SUFFICIENTLY AHEAD OF TIME TO ALLOW REDESIGN (IF DEEMED NECESSARY). THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURING AS A RESULT OF INCORRECTLY LOCATED UTILITIES/ NO EXTENSIONS OF CONTRACT TIME AND NO MONETARY DAMAGE CLAIMS SHALL BE ALLOWED AS A RESULT OF REVISED DESIGN LOCATIONS OR TIME ALLOWED TO DO THE SAME, WHICH SHALL RESULT FROM EXISTING UTILITIES BEING FOUND IN DIFFERENT LOCATIONS THAN SHOWN ON THESE DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER AND THE VARIOUS UTILITY OWNERS, IN AMPLE TIME, FOR THE OWNERS TO LOCATE AND MARK THEIR FACILITIES.
1.
ST
·
WATER MAIN(S) SHALL BE 8-INCH DUCTILE IRON CEMENT-LINED CLASS 52. WATER SERVICE(S) SHALL BE 1-INCH TYPE K COPPER FROM THE WATER MAIN TO THE CURB BOX AND 1-INCH (TYPE K SOFT COPPER OR PE #4710) FROM THE CURB BOX TO THE METER. WATER METER(S) SHALL BE LOCATED ON THE INTERIOR WALLS IMMEDIATELY UPON SERVICE ENTRANCE INTO THE BUILDING(S). ON METERED SERVICES REQUIRING A 1 1/2-INCH OR LARGER METER A BYPASS AROUND THE METER IS REQUIRED. ALL GATE VALVES SHALL HAVE STAINLESS STEEL BODY AND BONNET BOLTS.
MAXIMUM ALLOWABLE INFILTRATION OR EXFILTRATION SHALL NOT EXCEED 100 GALLONS PER INCH PER MILE OF PIPE PER DAY FOR THE SANITARY SEWER. IF AN AIR TEST IS USED, THE TEST, AS A MINIMUM, SHALL CONFORM TO THE PROCEDURE DESCRIBED IN THE ASTM-C-828-86, ENTITLED "STANDARD PRACTICE FOR LOW PRESSURE AIR TEST OF VITRIFIED CLAY PIPE LINES. SANTARY MANHOLES SHALL BE VISUALLY INSPECTED AND TESTED FOR LEAKAGE BY EXFILTRATION OR VACUUM. VACUUM TESTING OF MANHOLES SHALL COMPLY WITH THE METHOD OUTLINED IN THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION TECHNICAL INFORMATION PAMPHLET (TIP) NO. 15 (REVISED).
M.C.H.D. WATER MAIN NOTES
MI
· ·
1.
GENERAL UTILITY NOTES
D
SANITARY SEWER NOTES
PUBLIC WATER SYSTEM NOTES
AL
Civil Engineering
W.T.A.
TITLE OF DRAWING
Land Surveying
J.S.F. TOPO/BASE
Landscape Architecture
G.L.R.
UTILITY SECTION 2A PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
1"=40'
BELLA TERRA SUBDIVISION SECTION 2
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA110 SHEET 3 OF 9
W
W
OH
W
W
OH
.66 361
S
W
OH
RGE T157A
1.44%
293' - 15" PVC @
PROPOSED 8" D.I.P. CL 52 ZINC COATED
EXISTING SANITARY SEWER EASEMENT 10' WEST OF EX. SEWER TO R.O.W. TO TOWN OF WEBSTER PER LIBER 362 OF MAPS PAGE 44
OH
G
W
W
OH
OH
W
G
W
OH
W
OH
G
PROPOSED 1" COPPER WATER SERVICE TO THE CURB STOP. 1" PE PRIVATE SERVICE TO THE BUILDING
15" PVC
DB-16 5' DIA M.H. RIM=379.3
W
W
OH OH OH
362.1
362.23
PROPOSED 6" SDR-21 STORM LATERAL TYP.
ST SA
PROPOSED 4" SDR-21 SANITARY LATERAL TYP.
ST SA
LOT 226
W
TG=365.77
N/F 800 PHILLIPS ROAD LLC 1592 BELLORA WAY T.A. # 065.02-4-17
ST SA
RIM=369.01 C @1 .25%
8" PV
363.2 6
D 364.4 1
CS
ST SA
W
363.1 6
30" H D
W
PE @
SA ST
CS
WV
12" H DPE
WV TG=367.29
17 365.
D
DB-12.1 2'x2' INLET TG=369.5
W
GV
D
DB-11 5' DIA M.H. RIM=370.5
W
W
ST SA
W
ST SA
DB-12.2 2'x2' INLET TG=369.5
CS
ST
ST
LOT 259
LOT 250
LOT 260
DB-15A 5' DIA M.H. RIM=371.5
Y D
H
W
PROPOSED 1" COPPER WATER SERVICE TO THE CURB STOP. 1" PE PRIVATE SERVICE TO THE BUILDING
D
S
W
LOT 121
TG=364.26
TG=364.21
58"x36" CMP CULVERT N. INV=357.50 S. INV=357.80
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
N/F 800 PHILLIPS ROAD LLC 1575 SISTINE WAY T.A. # 065.02-4-21
LOT 230
254'-8" PVC @ 1.87%
S-12.1 4' DIA M.H. RIM=371.5
HYDRANT FLOW TEST DATA
VERDE WAY (60.0' WIDE R.O.W.)
S
W
354.67
EXISTING DRAINAGE EASEMENT TO THE TOWN OF WEBSTER PER LIBER 362 OF MAPS PAGE 44
354.53 CONC. HEADWALL
RIM=365.16
LOT 120
LOT 154
364.55
ST
LOT 252
PROPOSED 4" SDR-21 SANITARY LATERAL TYP.
D
CS
LOT 254
N/F 800 PHILLIPS ROAD LLC 1577 SISTINE WAY T.A. # 065.02-4-20
N/F 800 PHILLIPS ROAD LLC 1576 SISTINE WAY T.A. # 065.02-4-54
DB-15 5' DIA M.H. RIM=374.1
Y
APPROXIMATE LOCATION TOWN LOT 12
LOT 249
SA
STA 0+00 BELLORA WAY EQUALS STA 4+56.15 VERDE WAY
ST
END OF PROPOSED WATER MAIN, PROVIDE (2) LENGTHS OF PIPE PAST THE PROPOSED GATE VALVE, PROVIDE A TAPPED TEE WITH 2" BLOW-OFF AND USE BLOW-OFF AS TEMPORARY SAMPLING TAP.
LOT 256
APPROXIMATE LOCATION TOWN LOT 14
APPROXIMATE LOCATION OF EXISTING 8" DIP CLASS 52 WATER MAIN
PROPOSED 6" SDR-21 STORM LATERAL TYP.
ST
S-12 4' DIA M.H. RIM=374.5
PROPOSED HYDRANT. PROVIDE 8" GATE VALVE
SA
LOT 251
LOT 229 SA
W
CS
DB-14.2 2'x2' INLET TG=370.9
SA
LOT 253
CS
S
367.72 D
SA
W
H
CS
CS ST
264'-12" HDPE @ 1.7 7%
W
W
ST SA SA
W
W
W
LOT 255
DB-10.2 2'x2' INLET TG=369.2
RIM=365.87
LOT 153
SA
LOT 258
LOT 257
SA ST
DB-14.1 2'x2' INLET TG=370.9
ST
8" ZINC COATED D.I.P. WATERMAIN
SA ST
364.45
0%
CS
ST SA SA
CS
367.82 364.55
26'-12" HDPE @ 0.76% 10'-12" HDPE @ 1.04%
25'-12" HDPE @ 0.80%
W
CS CS
LOT 119
N/F 800 PHILLIPS ROAD LLC 1578 SISTINE WAY T.A. # 065.02-4-53
W
W
299'-18" HDPE @ 0.4
DB-15.1 2'x2' INLET TG=373.9
368.02
368.22
300'-8" PVC @ 0.40%
DB-14 5' DIA M.H. RIM=371.2
W
W
CS
363.25 366.52
368.10
CS
CS CS
368.30
W
W
23'-12" HDPE @ 0.43% W
WAY BELLORA R.O.W.) (60.0' WIDE
CS
W
S
152'-24" HD
DB-13 5' DIA M.H. RIM=370.1
7
366.42 D
PE @ 0.40% 6'-12" HDPE @ 1.63%
362.50 0 365.81 362.4 S D 1 .7 365
365.2
CS
366.75
0.40% 3'-8" PVC @
DB-15.2 2'x2' INLET TG=373.9
ST SA
4
TG=366.56
236'-
W
364.1
WV
40% @ 0.
24'-12" HDPE @ 0.95%
6'-12" HDPE @ 0.73%
W
N/F 800 PHILLIPS ROAD LLC T.A # 065.02-4-19
WV
CS
SA ST
W
NE W AY IDE R .O.W.)
SA ST
C 8" PV
CS
6 361.4 67 S 364.
364.57
%
E @ 0.40 154'-30" HDP
D 363.96
ST
W
LOT 152
CS
363.96
DB-10.1 2'x2' INLET 364.10 TG=370.2
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
8" PVC
N/F 800 PHILLIPS ROAD LLC 1580 SISTINE WAY T.A. # 065.02-4-52
S
364.20
(60.0' W
SISTE
358.00
S
RIM=367.53
LOT 151
361.36
360.76
RIM=369.71 363.8 6 RIM=369.56
W
W
CS
360.6 6
CS
W
ST SA
16
CS CS
10'-12" HDPE @ 0.56%
0.37%
S-11 4' DIA M.H. RIM=371.4
367.82
0.00%
SA ST
363.16
CS
LOT 228
CS
0.40%
PE @
DB-10: CONNECT TO EX. STRUCTURE INV=363.86 126'-30" HDPE @ 0.40% INV=363.96 INV=363.96 INV=363.96 153'-8" PVC @ 0.39%S-9 4' DIA M.H. ST SA SA ST RIM=370.6
S-8: CONNECT TO EX. STRUCTURE INV=360.66 INV=360.76
366.00
30" H D
TG= 367.48
WV
Y D
H
363.1
CS
SA ST
SA
SA ST
LOT 234
HDPE @
357.4 0
CS
SA ST
6
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-51
ST
SA ST
357.4 7
D
367.29
DB-12 5' DIA M.H. RIM=369.8
LOT 243
LOT 227
CS
SA
LOT 235
LOT 236
ST SA CS
CS
368.60
LOT 244
RIM=368.23
S
S-10 4' DIA M.H. RIM=370.2
110'-24" HDPE @ 0.40%
SA ST
LOT 233
ST
LOT 242
LOT 245
LOT 246
SA ST
LOT 239
LOT 240
DB-14A 2'x2' INLET TG=369.9
SA
365.37
8" PV C
W
RIM=367.99
LOT 237
LOT 238
ST
196'-12"
@ 0.38 %
LOT 247
LOT 248
LOT 241
239'-12 " HDPE
W
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM & SANITARY SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
198'-12" HDPE @ 1.01%
W
LOT 118
DB-10A 2'x2' INLET TG=367.4
8" ZINC COATED D.I.P. WATERMAIN
N/F 800 PHILLIPS ROAD LLC 1594 BELLORA WAY T.A. # 065.02-4-18
DB-12A END SECTION INV=368.00
136'-12" HDPE @ 0.40%
364.87
W
368.00
LOT 117
W
CS
CS
PROPOSED EASEMENT TO THE MCWA.
BE (60 LLOR .0' WI A W A DE R.O Y .W .)
S-13 4' DIA M.H. RIM=379.4
CS
LOT 232
363.29
W
S
W
12" HD PE
LOT 225
D
CS
D
1
'-1
93
372.50
TG=365.38
1.5
VC @ 0.4 0%
W
OH
EXISTING EASEMENT TO THE TOWN OF WEBSTER FOR STORM & SANITARY SEWER PURPOSES PER LIBER 362 OF MAPS PAGE 44
DP
37
207'-8" P
G
DP E
E
H 2"
@
0 3.0 37
LOT 231
W
12" H
0
W
APPROXIMATE LOCATION 20' WIDE SANITARY SEWER EASEMENT TO THE TOWN OF WEBSTER PER LIBER 8299 PAGE 109
DB-16.1 2'x2' INLET TG=377.0
4.4
1%
369.30
G
OH
W
APPROXIMATE LOCATION 20' WIDE SANITARY SEWER EASEMENT TO THE TOWN OF WEBSTER PER LIBER 8299 PAGE 109
WV
N
RIM=371.20
361.01
RIM=371.82
APPROXIMATE LOCATION OF 8" CI WATER MAIN PER M.C.W.A.
292' - 15" PVC @ 1.24%
365.24
296' - 15" PVC @ 1.14%
HYDRANT TO BE RELOCATED
368.87 368.94 RIM=378.18
VERDE WAY (60.0' WIDE R.O.W.)
W 361.77
WV
H
PROVIDE 8" GATE VALVE PROVIDE DISINFECTION AND SAMPLING TAP
365.09
Y D
S RIM=370.10
SHALLOW C
361 .85
% 0.8 2 C@
W
RIM=369.30
S
12" CMP N.INV=367.16 S.INV=367.24
PV
W
- 8"
W
92'
W
S
W
G
8" PVC
W
G
359.82
W
S
W
G
D
G
360.35
G
RGE 91
G
WV
G
RIM=370.02
RIM=369.87
W
G
15" PVC
359.88
W
G
SALT ROAD
GRID
G
S
G
(66' WIDE R.O.W.)
COUNTY ROAD 6
W
G
15" PVC APPROXIMATE LOCATION 15' WIDE EASEMENT TO ROCHESTER GAS & ELECTRIC CORPORATION PER LIBER 4944 PAGE 33
RIM=367.68
359.79
359.52
G
358.42
359.47
FURNISH AND INSTALL NEW 8”X8”X8” TAPPING SLEEVE AND VALVE. CONTRACTOR WILL PROVIDE EXCAVATION AND ALL MATERIALS FOR A SAFE EXCAVATION (PROPER TRENCH SHORING) WITH PLACEMENT OF AN ADEQUATELY SIZED THRUST BLOCK PER MCWA DETAIL. COORDINATE WITH MCWA TO SCHEDULE AND PERFORM THE TAP FOR A SET FEE. CONTRACTOR RESPONSIBLE FOR BACKFILLING WITH SUITABLE MATERIAL AND RESTORATION OF ALL GROUND SURFACES IMMEDIATELY UPON REMOVING THE SAMPLE TAP AFTER TESTING
361.90
W
358.34
PROVIDE 8" GATE VALVE PROVIDE DISINFECTION AND SAMPLING TAP
LIBER 10933 PAGE 36
G
FURNISH AND INSTALL NEW 8”X8”X8” TAPPING SLEEVE AND VALVE. CONTRACTOR WILL PROVIDE EXCAVATION AND ALL MATERIALS FOR A SAFE EXCAVATION (PROPER TRENCH SHORING) WITH PLACEMENT OF AN ADEQUATELY SIZED THRUST BLOCK PER MCWA DETAIL. COORDINATE WITH MCWA TO SCHEDULE AND PERFORM THE TAP FOR A SET FEE. CONTRACTOR RESPONSIBLE FOR BACKFILLING WITH SUITABLE MATERIAL AND RESTORATION OF ALL GROUND SURFACES IMMEDIATELY UPON REMOVING THE SAMPLE TAP AFTER TESTING
SALT ROAD
1705 SHALLOW CREEK TRAIL LIBER 11545 PAGE 567
G
EDWARD A. & SUSAN. DUFFY T.A. # 66.010-02-046 1696 SHALLOW CREEK TRAIL LIBER 10097 PAGE 477
FUTURE SECTIONS OF BELLA TERRA SUBDIVISION
DATA SUPPLIED BY THE MCWA LOCATION: SALT ROAD TEST DATE: 5/26/23 STATIC PRESSURE = 94 PSI OBSERVED FLOW = 1054 GPM RESIDUAL PRESSURE = 47 PSI Q20= 1347 GPM PLEASE NOTE THE FOLLOWING INFORMATION THE PRESSURE AND FLOW DATA PROVIDED HEREIN REPRESENTS THE CALCULATED VALUES FOR THIS LOCATION IN THE DISTRIBUTION SYSTEM BASED ON TYPICAL LOW OPERATING CONDITIONS. THESE VALUES CAN VARY DEPENDING ON DEMANDS, OPERATIONAL PARAMETERS, SYSTEM CONFIGURATIONS, SUBSEQUENT MODIFICATIONS AND OTHER RELATED CRITERIA. PLEASE CONTACT MONROE COUNTY WATER AUTHORITY WITH ANY ADDITIONAL QUESTIONS.
REMAINING LANDS SALT ROAD
MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH THESE PLANS FOR PUBLIC SANITARY SEWER EXTENSION / IMPROVEMENTS ARE HEREBY APPROVED PURSUANT TO ARTICLE 17 OF THE NYS ENVIROMENTAL CONSERVATION LAW SUBJECT TO CONDITIONS OF APPROVAL
DIRECTOR OF PUBLIC HEALTH
WATER MAINS AND APPURTENANCES TO BE CONSTRUCTED IN ACCORDANCE WITH THE REGULATIONS AND SPECIFICATIONS OF THE WATER AUTHORITY:
2.
LOT LINE
4" DIA. STORM DRAIN BEYOND CELLAR EXCAVATION
WHERE WATER SERVICE CROSSES STORM AND/OR SANITARY SEWER MAINS OR LATERALS, AN 18" MIN. SEPARATION IS REQUIRED.
GAR.
HOUSE 4" DIA.
DRIVEWAY
CLEAN OUT 10' MIN.
PE WATER SERVICE FROM THE CURB BOX TO THE HOUSE 6" DIA. STM LATERAL
LATERALS AND SERVICES TO EXTEND 11' PAST THE R.O.W. LINE OR 11' PAST A PERMANENT EASEMENT LINE, WHICHEVER IS GREATER.
4" DIA. SAN. LATERAL
FOR SETBACK INFO, SEE PLAT MAP FOR INDIVIDUAL LOT SPECIFICATIONS.
CURB BOX FOR THE WATER SERVICE ON R.O.W. LINE R.O.W. LINE
11'
·
1.
COPPER WATER SERVICE FROM THE WATERMAIN TO THE CURB BOX.
4.
5.
3. WHEN INSTALLING FIRE HYDRANTS, SHOULD GROUND WATER BE ENCOUNTERED WITHIN SEVEN (7) FEET OF THE FINISHED GRADE, FIRE HYDRANT WEEP HOLES (DRAINS) SHALL BE PLUGGED.
SECTION/PARCEL BOUNDARY PROPOSED RIGHT-OF-WAY PROPOSED LOT LINE PROPOSED EASEMENT LINE MIN. BUILDING SETBACK CENTER LINE EXIST. ADJOINING PROPERTY LINE EXIST. EASEMENT LINE EXIST. RIGHT-OF-WAY LINE EXIST. EDGE OF PAVEMENT
4. THE WATER MAIN SHALL BE PRESSURE/LEAKAGE TESTED IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE AWWA STANDARD C600 (LATEST REVISION) OR IN ACCORDANCE WITH
TOWN DRIVEWAY NOTES
THE CONTRACTOR SHALL LOCATE, MARK, SAFEGUARD AND PRESERVE ALL SURVEY CONTROL MONUMENTS AND RIGHT-OF-WAY MONUMENTS IN THE AREA OF THE SITE CONSTRUCTION, FOR DESCRIPTIVE AND SURVEY DATA PERTAINING TO THE MONUMENTS, CALL THE MONROE COUNTY GEODETIC SURVEY OFFICE. ALL SANITARY SEWERS, STORM SEWERS, WATER MAINS, AND APPURTENANCES, NOT WITHIN A DEDICATED RIGHT-OF-WAY, SHALL BE DEDICATED TO THE PROPER, GOVERNING AGENCY. THE DEDICATION SHALL BE CONDUCTED THROUGH EASEMENTS, WHICH SHALL BE SHOWN AND DESCRIBED AT THE FINAL STAGE OF PLANS.
1.
DRIVEWAYS ARE NOT PERMITTED OVER MANHOLES, CLEAN-OUTS, VALVES AND CATCH BASINS.
2.
DRIVEWAY CONNECTIONS ARE NOT PERMITTED IN THE VICINITY OF RECEIVING BASINS AND/OR THE TEMPORARY TURNAROUND.
3.
DRIVEWAY CONNECTIONS ARE NOT ALLOWED WITHIN 10' OF A HYDRANT.
DRIVEWAYS ARE NOT PERMITTED OVER MANHOLES, CLEAN-OUTS, VALVES AND CATCH BASINS
EXIST. WATER MAIN, GATE VALVE & HYDRANT EXIST. SANITARY SEWER & MANHOLE
W
4.
DRIVEWAYS TO HAVE 5 FOOT MINIMUM SEPARATION.
STORM SEWER LATERALS, FOR SINGLE-FAMILY HOMES ARE TO BE 6" DIA. P.V.C., SDR-35, AND ARE TO EXTEND (11) ELEVEN FEET BEYOND THE RIGHT-OF-WAY LINE OR (11) ELEVEN FEET BEYOND AN EASEMENT LINE (WHICHEVER IS GREATER).
1. 2.
DATE:
LEGEND BY:
ALL CROSSOVER PIPES SHALL BE PERFORATED HDPE.
W
Y
PROP. WATER MAIN, GATE VALVE & HYDRANT PROP. SANITARY SEWER & MANHOLE
PLANNING BOARD CHAIRPERSON
BY:
TOWN HIGHWAY SUPERINTENDENT
BY:
WEBSTER SEWER DISTRICT
BY:
TOWN ASSESSOR
EXIST. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION BY:
FIRE MARSHAL
PROP. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION
ALL ROADWAY WEEPS SHALL HAVE UNDERDRAIN THE FULL LENGTH OF THE ROAD.
PROP. GUTTER AND CATCH BASIN
BY:
MONROE COUNTY WATER AUTHORITY
2.
3.
4.
5.
ROOF LEADERS SHALL BE CONNECTED TO THE STORM SEWER DRAINAGE SYSTEM VIA A 6" PIPE WITH CLEANOUTS. FOUNDATION DRAINS SHALL BE CONNECTED TO THE STORM SEWER LATERALS VIA A SUMP PUMP. STORM SEWER PIPE MATERIAL OPTIONS ARE AS FOLLOWS: a) POLYVINYL CHLORIDE (P.V.C.) SDR-35. b) CORRUGATED POLYETHYLENE HIGH DENSITY PLASTIC (C.P.P.) ALL STORM PIPE CONNECTIONS TO BE WATER TIGHT.
PROJECT MANAGER
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
GRAPHIC SCALE 40
0
20
80
40
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
160
( IN FEET ) 1 inch = 40 ft. NO.
DATE
REVISION
BY
CHKD.
APVLS.
TE EL O R I T Y
DRAWN BY
BOUNDARY
C
HA
PR
0 9 6 1 84
OFE
SS I
TITLE OF PROJECT
W.T.A.
OF NEW
ED
NOT TO SCALE
SANITARY SEWER LATERALS, FOR THE SINGLE-FAMILY HOMES, ARE TO BE 4" DIA. P.V.C., SDR-21 OR SCH 40, AND SHALL EXTEND ELEVEN (11) FEET BEYOND THE RIGHT-OF-WAY LINE OR(11) ELEVEN FEET BEYOND AN EASEMENT LINE. (WHICHEVER IS GREATER)
DATE
TOWN ENGINEER
NS
TYPICAL LATERAL LAYOUT DETAIL
5.
BY:
L I CE
WATERMAIN CROSSING IS SUBJECT TO M.C.H.D. REGULATIONS
8" MIN. DIA. WATERMAIN
SANITARY SEWER MAINS ARE TO BE POLYVINYL CHLORIDE (P.V.C.), SDR-35, UNLESS DEPTHS EXCEED 12' IN WHICH CASE USE SDR-21.
RK O IE
R.O.W. LINE HYDRANT IN LINE WITH PROPERTY LINE BOUNDARY
W
4.
PUBLIC HEALTH ENGINEER
APPROVALS
H
W
MANHOLES ARE NOT TO CONFLICT WITH DRIVEWAY
THE DEVELOPERS AND CONTRACTORS ATTENTION IS DIRECTED TO LOCAL LAW NO. 6 OF 1971, REGARDING LIABILITY INCURRED THROUGH THROUGH DISTURBANCE OR DESTRUCTION OF GEODETIC SURVEY MONUMENTS, THE CONTRACTOR SHALL LOCATE, MARK, SAFEGUARD AND PRESERVE ALL SURVEY CONTROL MONUMENTS AND RIGHT-OF-WAY MONUMENTS IN THE AREA OF CONSTRUCTION. FOR MORE DESCRIPTIVE AND SURVEY DATA ON CONTROL MONUMENTS, CALL THE MONROE COUNTY GEODETIC SURVEY OFFICE.
STORM SEWER NOTES
SANITARY SEWER STORM SEWER WYE
ROAD CENTERLINE
·
3.
2. MINIMUM VERTICAL SEPARATION BETWEEN WATER MAINS AND SEWER PIPES SHALL BE 18 INCHES MEASURED FROM THE OUTSIDE OF THE PIPES AT THE POINT OF CROSSING. ONE FULL STANDARD LAYING LENGTH OF WATER MAIN SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. IN ADDITION, WHEN THE WATER MAIN PASSES UNDER A SEWER, ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECT FILL), SHALL BE PROVIDED FOR THE SEWER TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING OF THE SEWER ON THE WATER MAIN. MINIMUM HORIZONTAL SEPARATION BETWEEN PARALLEL WATER MAINS AND SEWER PIPES (INCLUDING MANHOLES AND VAULTS) SHALL BE 10 FEET MEASURED FROM THE OUTSIDE OF THE PIPES, MANHOLES OR VAULTS.
H
CLEANOUT(S), ON R.O.W. LINE OR EASEMENT LINE; EXTEND LATERAL 11' PAST CLEAN OUT. PROVIDE BRASS CAP.
·
ALL IMPROVEMENTS SHALL BE DONE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE TOWN OF WEBSTER, THE MONROE COUNTY HEALTH DEPARTMENT, THE MONROE COUNTY WATER AUTHORITY, THE MONROE COUNTY DEPARTMENT OF TRANSPORTATION, AND ANY OTHER AGENCY HAVING JURISDICTION.
ER
NOTES:
WATER MAINS AND ALL WATER SERVICE LINES SHALL HAVE A MINIMUM OF FIVE FEET OF COVER FROM FINISHED GRADE IN LAWN AREAS AND A MINIMUM OF SIX FEET OF COVER FROM FINISHED GRADE IN PAVED AREAS. MINIMUM VERTICAL SEPARATION BETWEEN WATER MAIN AND SEWER MAINS SHALL BE 18" MEASURED FROM OUTSIDE OF PIPES AT THE POINT OF CROSSING. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER MAINS AND SEWER MAINS SHALL BE TEN FEET MEASURED FROM OUTSIDE OF THE PIPES. ONE FULL LENGTH OF WATER MAIN SHALL BE CENTERED UNDER OR OVER THE SEWER SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. WHERE A WATER MAIN CROSSES UNDER A SEWER ADEQUATE STRUCTURAL SUPPORT (COMPACTED SELECTED FILL) SHALL BE PROVIDED FOR THE SEWERS TO PREVENT EXCESSIVE DEFLECTION OF JOINTS AND SETTLING ON AND BREAKING THE WATER MAINS. FIRE HYDRANT WEEP HOLES (DRAINS) SHALL BE PLUGGED WHEN GROUND WATER IS ENCOUNTERED WITHIN SEVEN FEET OF THE FINISHED GRADE. ALL MECHANICAL JOINT FITTINGS (TEES, BENDS, PLUGS, ETC.) SHALL BE BACKED WITH 2500 PSI CONCRETE THRUST BLOCKS OF APPROPRIATE SIZE TO PROVIDE THRUST RESTRAINT. SEPT 2017
2.
BY
I NE
·
GUTTER INLET
LOT LINE
FLOOR DRAINS, IF CONSTRUCTED IN THE PROJECT, MUST BE CONNECTED TO THE SANITARY SEWER. NOTE: FLOOR DRAINS DO NOT INCLUDE FOUNDATION OR FOOTER DRAINS INSTALLED TO INTERCEPT UNCONTAMINATED GROUND WATER. ALL DISCHARGES FROM THE FLOOR DRAINS TO THE SANITARY SEWER MUST COMPLY WITH THE EFFLUENT LIMITS OF THE LOCAL AND/OR THE MONROE COUNTY SEWER USE LAW.
DIRECTOR OF PUBLIC HEALTH
NG
·
3.
DATE
THESE PLANS FOR PUBLIC WATER SYSTEM EXTENSION / IMPROVEMENT ARE HEREBY APPROVED PURSUANT TO 10NYCRR5 OF THE STATE SANITARY CODE SUBJECT TO CONDITIONS OF APPROVAL
E
·
DEFLECTION TESTS SHALL BE PERFORMED ON ALL FLEXIBLE PIPE. THE TEST SHALL BE CONDUCTED AFTER THE FINAL BACKFILL HAS BEEN IN PLACE AT LEAST THIRTY DAYS. NO PIPE SHALL EXCEED A DEFLECTION OF 5%. IF THE DEFLECTION TEST IS TO BE RUN USING A RIGID BALL OR MANDREL, IT SHALL HAVE A DIAMETER EQUAL TO 95% OF THE INSIDE DIAMETER OF THE PIPE, THE TEST SHALL BE PERFORMED WITHOUT THE AID OF MECHANICAL PULLING DEVICES.
PUBLIC HEALTH ENGINEER
MONROE COUNTY DEPARTMENT OF PUBLIC HEALTH
A
·
SOIL TEST. THE CONTRACTOR SHALL PROVIDE A SOIL TEST EVALUATION TO DETERMINE THE NEED FOR POLYETHYLENE ENCASEMENT PER ANSI/AWWS C105/AZ1.5-82 PRIOR TO WATER MAIN INSTALLATION. SOIL TESTING SHALL BE CONDUCTED BY AN APPROVED SOIL TESTING LABORATORY IN ACCORDANCE WITH WATER AUTHORITY STANDARDS. PRESSURE TEST. WATER MAINS TO BE PRESSURE TESTED IN ACCORDANCE WITH THE LATEST WATER AUTHORITY SPECIFICATIONS. A WATER AUTHORITY REPRESENTATIVE MUST WITNESS THIS TEST. HEALTH SAMPLE. THE WATER MAIN SHALL BE DISINFECTION EQUAL TO AWWA STANDARD SPECIFICATIONS, DESIGNATION C-651, BY USING THE CONTINUOUS FEED METHOD. AFTER FLUSHING AND DISINFECTING THE WATER MAIN, WATER SAMPLES SHALL BE COLLECTED FROM THE MAIN BY THE MONROE COUNTY HEALTH DEPARTMENT. FIRE HYDRANTS ARE NOT ACCEPTABLE SAMPLING POINTS. APPROVAL AND NOTIFICATION BY THE HEALTH DEPARTMENT MUST BE RECEIVED BEFORE THE MAIN IS PLACED IN SERVICE.
1. THE WATER MAIN SHALL BE DISINFECTED EQUAL TO A.W.W.A. STANDARD FOR "DISINFECTING OF WATER MAINS, DESIGNATION C651" (LATEST REVISION). FOLLOWING DISINFECTION, THE WATERMAIN SHALL BE FLUSHED UNTIL THE CHLORINE CONCENTRATION, IN THE WATER LEAVING THE MAIN, IS NO HIGHER THAN THAT GENERALLY PREVAILING IN THE SYSTEM. ALL WATER MAIN FITTINGS NOT RECEIVING 24-HOUR CHLORINE DISINFECTION CONTACT TIME MUST BE SWAB DISINFECTED 30 MINUTES PRIOR TO INSTALLATION. THE SAMPLING POINT(s) MUST BE DECONTAMINATED BY FLAMING. FIRE HYDRANTS ARE NOT ACCEPTABLE SAMPLING POINTS. THE MONROE COUNTY DEPARTMENT OF HEALTH MUST RECEIVE AT LEAST 48-HOUR ADVANCE NOTIFICATION REQUESTING SAMPLING SERVICES. SAMPLING WILL NOT BE PERFORMED PRIOR TO RECEIPT FROM A NEW YORK STATE LICENSED OR REGISTERED DESIGN PROFESSIONAL (ENGINEER, ARCHITECT OR LAND SURVEYOR WITH A SPECIAL EXEMPTION UNDER SECTION 7208(n) OF THE EDUCATION LAW) CERTIFYING THAT THE WATER SUPPLY IMPROVEMENTS, TESTING AND DISINFECTION PROCEDURES WERE COMPLETED IN ACCORDANCE WITH THE APPROVED PLANS, REPORTS, SPECIFICATIONS AND ANY APPROVED AMENDMENTS. THE DEPARTMENT WILL COLLECT SAMPLES FOR FREE CHLORINE RESIDUAL, TOTAL COLIFORM, ESCHERICHIA COLI (E. COLI) AND TURBIDITY. THE WATER MAIN SHALL NOT BE PLACED INTO SERVICE UNTIL SO AUTHORIZED BY THE MONROE COUNTY DEPARTMENT OF HEALTH.
C
·
BY
EXISTING UTILITIES (LOCATIONS, SIZES, MATERIALS & INVERTS) SHOWN ON THE PLANS, HAVE BEEN PLOTTED FROM FIELD SURVEYS AND RECORD MAPS AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION AND/OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF OR CLOSELY PARALLEL TO, OR UNDER THE PROPOSED CON-STRUCTION, SUFFICIENTLY AHEAD OF TIME TO ALLOW REDESIGN (IF DEEMED NECESSARY). THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURING AS A RESULT OF INCORRECTLY LOCATED UTILITIES/ NO EXTENSIONS OF CONTRACT TIME AND NO MONETARY DAMAGE CLAIMS SHALL BE ALLOWED AS A RESULT OF REVISED DESIGN LOCATIONS OR TIME ALLOWED TO DO THE SAME, WHICH SHALL RESULT FROM EXISTING UTILITIES BEING FOUND IN DIFFERENT LOCATIONS THAN SHOWN ON THESE DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER AND THE VARIOUS UTILITY OWNERS, IN AMPLE TIME, FOR THE OWNERS TO LOCATE AND MARK THEIR FACILITIES.
1.
MI
·
WATER MAIN(S) SHALL BE 8-INCH DUCTILE IRON CEMENT-LINED CLASS 52. WATER SERVICE(S) SHALL BE 1-INCH TYPE K COPPER FROM THE WATER MAIN TO THE CURB BOX AND 1-INCH (TYPE K SOFT COPPER OR PE #4710) FROM THE CURB BOX TO THE METER. WATER METER(S) SHALL BE LOCATED ON THE INTERIOR WALLS IMMEDIATELY UPON SERVICE ENTRANCE INTO THE BUILDING(S). ON METERED SERVICES REQUIRING A 1 1/2-INCH OR LARGER METER A BYPASS AROUND THE METER IS REQUIRED. ALL GATE VALVES SHALL HAVE STAINLESS STEEL BODY AND BONNET BOLTS.
MAXIMUM ALLOWABLE INFILTRATION OR EXFILTRATION SHALL NOT EXCEED 100 GALLONS PER INCH PER MILE OF PIPE PER DAY FOR THE SANITARY SEWER. IF AN AIR TEST IS USED, THE TEST, AS A MINIMUM, SHALL CONFORM TO THE PROCEDURE DESCRIBED IN THE ASTM-C-828-86, ENTITLED "STANDARD PRACTICE FOR LOW PRESSURE AIR TEST OF VITRIFIED CLAY PIPE LINES. SANTARY MANHOLES SHALL BE VISUALLY INSPECTED AND TESTED FOR LEAKAGE BY EXFILTRATION OR VACUUM. VACUUM TESTING OF MANHOLES SHALL COMPLY WITH THE METHOD OUTLINED IN THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION TECHNICAL INFORMATION PAMPHLET (TIP) NO. 15 (REVISED).
M.C.H.D. WATER MAIN NOTES
ST
· ·
1.
GENERAL UTILITY NOTES
D
SANITARY SEWER NOTES
PUBLIC WATER SYSTEM NOTES
L O NA
Civil Engineering
W.T.A.
TITLE OF DRAWING
Land Surveying
J.S.F. TOPO/BASE
Landscape Architecture
G.L.R.
UTILITY SECTION 2B PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
1"=40'
BELLA TERRA SUBDIVISION SECTION 2
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA111
SHEET 4 OF 9
RIM=367.10
N
D TG=363.95 368
TG=363.26
SF
36 9
368
367
368
364
SF
368
LOD
E
E
E
E
E
LO D
E
E
E
E
E
E
E
APPROXIMATE LOCATION TOWN LOT 14
LOD
LOD
LOT 120
E
E
E
E
E
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
E
E
E
E
E
LOD
TRA OD
D
ARR
LOD
LOD
LOD D LO
0' W
IDE
R.O .W.
LOD
O (60. WWO
)
IL
LOD
TOWN OF WEBSTER OPEN SPACE
SF
SF
371
2 37
37 0 SF
APPROXIMATE LOCATION TOWN LOT 12
E
LO D
LOD
LOT 121
MEADOWS TWO SUBDIVISION
D
SF
1 37
371
370
SF
LOD
(60.0' WIDE R.O.W.)
SF
LOD
E
E
LOT 122
LOT 123
LO
WOODS
363
LOD
LOD
LOD
LOT 124
SF
5 36
D LO SF 36
0 36 1
X
SF D LO
SF
SF
LO
D
371
LOD
LO D
E
LOD
D
LO D
LOD
LOD
LOD D
LOD
16+00
D
LO
LOT 125
LOT 126
LOT 127
REMAINING LANDS SALT ROAD (ZONED: LMR)
LO
D D
D
APPROXIMATE LOCATION TOWN LOT 6
D
LOD
LOD
LOD
LOD
LOD
APPROXIMATE LOCATION TOWN LOT 12
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
15+71
LOD
LOD
LOD
LOD
LOD
371
36 5 36 1
7
LOD
D
DD-2 TG=367.6
LO
MAINTAIN EXISTING GRADE OVER PROPOSED STORM SEWER
APPROXIMATE LOCATION TOWN LOT 7
X
LOD
LOD LOD
LOD
2
LOD
ARROWWOOD TRAIL LO
DD3 TG=365.0
E
LOD
369
D
LOD
RIP RAP OUTLET PROTECTION TYP.
DD END SECTION INV=360.65
DC-4 TG=361.0
DC-3 TG=365.8
SF
LOD
LOD
SF
E
LOD
SF
LO
WOODS
SF
SF
SF
SF
SF
SF
LOD
SF
LOD
SILT FENCE TYP.
SF
SF
LO D
S00° 55' 15"E 726.83'
SF
LOD
SF
SF
E
S
36
369
X
X
X
E
36
D
X
X X
SF
CHECK DAMS TYP.
X
X
X
X
X
X
358
APPROXIMATE LOCATION TOWN LOT 14
SF
SF
X
X
X
X
357
36 7 X
X
X X
DD-1 TG=367.3
TEMPORARY TOPSOIL STOCKPILE
369
E
LOD
LO
362 361
36 6
17+00
DC-5 END SECTION INV=360.65
SF
359
358 357
SF
SF
365 364 SF 363
SF
SF
8
E
SF
359
36
E
SF
E
LOD
SF
360
37 0
E
LOD SF
EDGE OF BRUSH / HEDGEROW
N/F XEROX CORPORATION T.A. # 65.020-01-040.110 750 PHILLIPS ROAD
LOD
LOD
360
D
D LO
SILT FENCE SURROUNDING PROPOSED BIO-RETENTION BASIN
361
0
LOT 132
EDGE OF BRUSH / HEDGEROW
SF
36 1
LOT 208
LOT 207
LO
LOT 206
D LO
LOT 205
LOT 209
D
LOT 204
GARAGE ELEV. =367.3
LOT 210
1
37
D
LOT 203
GARAGE ELEV. =367.3
X X
LO
GARAGE ELEV. =366.3
GARAGE ELEV. =370.5
DC-10.1 END SECTION INV=368.00 X
GARAGE ELEV. =366.3
GARAGE ELEV. =368.3
SF
LOT 131
1
37
GARAGE ELEV. =370.5
GARAGE ELEV. =368.3
3 37
37
SF
9
DC-8 RIM=368.4
D LO
8 36
S-1.6 RIM=366.1
36
362
LOT 201 362
DC-7 RIM=368.1 S-1.7 RIM=368.1
370
LOT 211
S-1.8 RIM=368.5
SF
SF
36 2
S
LO
S
SF 6 36
D
S
LOT 133 N/F 800 PHILLIPS ROAD LLC 535 TERRA VERDE WAY T.A. # 065.02-4-31
D
S
18+00
LOT 202
363
363
3
60
D
GARAGE ELEV. =371.5
X
64
SF
N/F 800 PHILLIPS ROAD LLC 525 TERRA VERDE WAY T.A. # 065.02-4-33
3
GARAGE ELEV. =364.3
D
SF
GARAGE ELEV. =364.3
LO
364
DC-6A RIM=365.1 S-1.5 RIM=365.1
SF
DA-5.2 RIM=364.2
S
X
LO D
364
D
DC-6 RIM=365.8
(60.0' W
LOT 212
373
363
LO
D
X
X
D
X
GARAGE ELEV. =371.5
S-1.9 RIM=370.1 DC-9 RIM=370.0
LO D
DC-6.1 TG=365.3
X
D
S
LOT 213
S
7+00
X
X
ERDE WAY TERRA VID E R.O.W.)
4+00
3+00
X
RIM=364.02
X
DC-8.1 TG=368.2
5+00
X
X
S
D RIM=362.14
D X
18+91
6+00
X
REMAINDER OF LI
D LO
DC-8.2 TG=368.2 X
RIM=364.08
2
00 8+
X
X X
GARAGE ELEV. =372.5
S-1.10 RIM=371.1 DC-10 RIM=371.0
37
D
LOT 214
DC10.1 TG=370.4
D S
0
9
DC-6.2 TG=365.3
2+00
∆=5°16'19" R=1500.00' L=138.02' 3 CHD=N02°32'31"E 36 137.97'
GARAGE ELEV. =372.5
37
36
INLET PROTECTION TYP.
0+00
TG= 3 361.39 62
X
GARAGE ELEV. =369.3
00
X
368
1+00 36 1
GARAGE ELEV. =369.3
LO
2 37
GARAGE ELEV. =368.1
GARAGE ELEV. =370.5
X
9+
GARAGE ELEV. =370.5
X
P. C. STA 1+38.02
4
362
LOT 219
X
LOD
GARAGE ELEV. =368.1
LOT 218
X
LOT 222
LOD
LOD
36
STABILIZED CONSTRUCTION ENTRANCE
371
X
X
LOD
D
X
3 36
X X
LO
X
RIM=362.87
SF
8 36
X
TG=361.85
X
DC-10.2 TG=370.4
LOT 217
LOT 221
SF
GARAGE ELEV. =365.8
SF
372
10+00
SF
D
3
SF
X X
N/F 800 PHILLIPS ROAD LLC 531 TERRA VERDE WAY T.A. # 065.02-4-32
D
372
GARAGE ELEV. =371.5
LO D
TG=361.67
X
N/F 800 PHILLIPS ROAD LLC 521 TERRA VERDE WAY # 065.02-4-34
LO
70
GARAGE ELEV. =371.5
LOT 220
LO D
LOT 130
LO
362
LOT 166
60' R.O.W.
9
D
LOD
5 36
364
GARAGE ELEV. =365.8
LO D
LOT 216 D LO
364
LOT 223
371
SF
LO
LOT 224
D
D
D
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-30
LO
D
RIM=362.87
SF 365
366
363
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-66
371
LOT 215
363
LOT 129
(60.0' WIDE R.O.W.)
36
365
LOD
LOD
DC-11 RIM=372.1
S-1.11 RIM=372.1
LOD
366
LOT 128
1 37
S
D LO
D
LO
N/F 800 PHILLIPS ROAD LLC 1553 SISTINE WAY T.A. # 065.02-4-29
TERRA VERDE WAY
SF
3 36
N/F 800 PHILLIPS ROAD LLC 1555 SISTINE WAY T.A. # 065.02-4-28
8
36
8
LOD
TG=361.14
LOT 135
36
366
D LO
LOT 165
TERRA VERDE WAY
D
LO
SILT FENCE OD TYP.L
D
N/F 800 PHILLIPS ROAD LLC 1551 BELLORA WAY T.A. # 065.02-4-35
D
10+96
37 0
SF
LO
LOT 164
LOT 136
LO
SF
LIMITS OF DISTURBANCE SECTION 2 A 10.78 ACRES
LIMITS OF TOPSOIL PILE TO BE REMOVED
N/F 800 PHILLIPS ROAD LLC 1554 SISTINE WAY T.A. # 065.02-4-65
370
SF 367
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-27
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 1556 SISTINE WAY T.A. # 065.02-4-64
N/F 800 PHILLIPS ROAD LLC 1553 BELLORA WAY T.A. # 065.02-4-36
LOD
D LO
366
LOT 137
D
LO
D
LOT 127 N/F 800 PHILLIPS ROAD LLC 1555 BELLORA WAY T.A. # 065.02-4-37
LOD LO
LOT 163
BELLA TERRA SECTION 1
SF
N/F 800 PHILLIPS ROAD LLC 1558 SISTINE WAY T.A. # 065.02-4-63
LOT 138
SF
N/F 800 PHILLIPS ROAD LLC 1557 BELLORA WAY T.A. # 065.02-4-38
LOD
LOD
REMAINING LANDS SALT ROAD (ZONED: LMR)
LO
S
4 36
LOD
D
.) (60.0' WIDE R.O.W
TG=363.65
EDGE OF BRUSH / HEDGEROW
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
SF
RIM=364.18
T
SF
LOT 162
R CARBELLA COU
SF
TG=364.02
SF
LOT 139
9
SF
N/F 800 PHILLIPS ROAD LLC 1560 SISTINE WAY T.A. # 065.02-4-62
36
RIM=364.66
SF
N/F 800 PHILLIPS ROAD LLC 1559 BELLORA WAY T.A. # 065.02-4-39
RIM=364.66
D
S
LOT 126
RIM= 366.92
800 PHILLIPS ROAD LLC T.A. # 065.02-4-26
LOT 161
GRID
LOT 140
N/F 800 PHILLIPS ROAD LLC 1561 BELLORA WAY T.A. # 065.02-4-40
FUTURE SECTIONS MEADOWS TWO SUBDIVISION
LEGEND NOTES:
PERFORATED PIPE, COLLECTION SYSTEM OVERFLOW 'CATCH BASIN'
BERM
D
SECTION/PARCEL BOUNDARY PROPOSED RIGHT-OF-WAY PROPOSED LOT LINE PROPOSED EASEMENT LINE MIN. BUILDING SETBACK CENTER LINE EXIST. ADJOINING PROPERTY LINE EXIST. EASEMENT LINE EXIST. RIGHT-OF-WAY LINE EXIST. EDGE OF PAVEMENT
DRIVEWAYS ARE NOT PERMITTED 1. ALL CROSSOVER PIPES SHALL BE PERFORATED HDPE. OVER MANHOLES, CLEAN-OUTS, VALVES AND CATCH BASINS 2.
OUTLET
ALL ROADWAY WEEPS SHALL HAVE UNDERDRAIN THE FULL LENGTH OF THE ROAD.
2:1 SLOPE 1.5' MAX.
3:1 SLOPE
12" MIN. 24" MAX.
12"
STAKE
EXIST. WATER MAIN, GATE VALVE & HYDRANT EXIST. SANITARY SEWER & MANHOLE
W
EXIST. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION
FABRIC
20' MIN. WIDTH STORM DRAINAGE EASEMENT TO THE TOWN OF WEBSTER
SECTION VIEW
EXISTING PAVEMENT
ELEV=A (C+1.5' MIN.)
1.
AS REQUIRED, 100 FT. MIN. FOR ACCESS TO COUNTY OR STATE ROADS, OTHERWISE, 50 FT. (EXCEPT ON SINGLE RESIDENCE LOT WHERE A 30 FT. MINIMUM LENGTH SHALL APPLY.
WIDTH
2% MIN. SLOPE 1 FILTER FABRIC
1 1
1
6"
SECTION B-B
RIGHT-OF-WAY LINE
THE SEDIMENTATION TRENCH SHALL BE EXCAVATED OR SHAPED TO LINE, GRADE, AND CROSS SECTION AS REQUIRED TO MEET THE CRITERIA SPECIFIED HEREIN, AND BE FREE OF BANK PROJECTIONS OR OTHER IRREGULARITIES WHICH WILL IMPEDE NORMAL FLOW. FILLS SHALL BE COMPACTED AS NEEDED TO PREVENT UNEQUAL SETTLEMENT THAT WOULD CAUSE DAMAGE TO THE TRENCH. STABILIZATION SHALL BE DONE ACCORDING TO THE APPROPRIATE STANDARD AND SPECIFICATIONS FOR VEGETATIVE PRACTICES.
CONSTRUCTION SPECIFICATIONS 1. 2.
3. 4. 5.
STONE WILL BE PLACED ON A FILTER FABRIC FOUNDATION TO THE LINES, GRADES AND LOCATIONS SHOWN IN THE PLAN. SET SPACING OF CHECK DAMS TO ASSUME THAT THE ELEVATIONS OF THE CREST OF THE DOWNSTREAM DAM IS AT THE SAME ELEVATION OF THE TOE OF THE UPSTREAM DAM. EXTEND THE STONE A MINIMUM OF 1.5 FEET BEYOND THE DITCH BANKS TO PREVENT CUTTING AROUND THE DAM. PROTECT THE CHANNEL DOWNSTREAM OF THE LOWEST CHECK DAM FROM SCOUR AND EROSION WITH STONE OR LINER AS APPROPRIATE. ENSURE THAT CHANNEL APPURTENANCES SUCH AS CULVERT ENTRANCES BELOW CHECK DAMS ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONE. MAXIMUM DRAINAGE AREA 2 ACRES.
SEDEMENTATION TRENCH DETAIL
CHECK DAM DETAIL
NOT TO SCALE
NOT TO SCALE
ROAD CENTERLINE
STORM SEWER
1. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION.
GUTTERS
2. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER, THEY SHALL BE OVERLAPPED BY 6" AND FOLDED.
RIGHT-OF-WAY LINE
NOTES:
347
347
1. SEE 225-44 OF THE TOWN CODE ZONING ORDINANCE FOR MIN. HEIGHT OF FIRST FLOOR ELEVATIONS WITH RELATION TO THE ELEVATION AT THE ROAD CROWN. 2. WHEN BUILT-IN AREA IS NOT ON STORM SEWER RUN, SPLASH BLOCKS MAY BE PERMITTED.
PERSPECTIVE VIEW CONSTRUCTION NOTES:
MANHOLE (SEE PLAN VIEW FOR INVERTS)
18"
ALL TREES, BRUSH, STUMPS, OBSTRUCTIONS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE REMOVED AND DISPOSED OF SO AS NOT TO INTERFERE WITH THE PROPER FUNCTIONING OF THE SEDIMENTATION TRENCH.
1' MIN.
347
F.F.=348.5
EXISTING GRADE PROPOSED GRADE FLOW DIRECTION EASEMENT LINE SPLASH BLOCKS SUMP PUMP FIRST FLOOR ELEV.
3. MAINTENANCE SHALL BE PERFORMED AS NEEDED, AND MATERIAL REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE.
SECTION VIEW
2. 36" MIN. FENCE POSTS, DRIVEN 16" MIN. INTO THE GROUND.
UNDIST. GROUND
FLOW EMBED FILTER CLOTH MIN. 8" INTO GROUND
POST MATERIAL:
STEEL, EITHER T OR U TYPE, OR 2" HARDWOOD.
FILTER CLOTH:
FILTER X, MIRAFI 100X, STABILINKA T140N, OR EQUAL.
PREFABRICATED UNIT:
GEOFAB, ENVIROFENCE, OR APPROVED EQUAL.
TYPICAL LOT GRADING DETAIL
FILTER FABRIC SILT FENCING DETAIL
NOT TO SCALE
NOT TO SCALE
BY:
CUT FABRIC FROM A CONTINUOUS ROLL TO ELIMINATE JOINTS. IF JOINTS ARE NEEDED THEY WILL BE OVERLAPPED TO THE NEXT STAKE.
PLANNING BOARD CHAIRPERSON
1. FILTER FABRIC SHALL HAVE AN EOS OF 40-85. BURLAP MAY BE USED FOR SHORT TERM APPLICATIONS.
BY:
TOWN HIGHWAY SUPERINTENDENT
3.
STAKE MATERIALS WILL BE STANDARD 2" x 4" WOOD OR EQUIVALENT. METAL WITH A MINIMUM LENGTH OF 3 FEET.
4.
SPACE STAKES EVENLY AROUND INLET 3 FEET APART AND DRIVE A MINIMUM 18 BY: WEBSTER SEWER DISTRICT INCHES DEEP. SPANS GREATER THAN 3 FEET MAY BE BRIDGED WITH THE USE OF WIRE MESH BEHIND THE FILTER FABRIC FOR SUPPORT.
5.
FABRIC SHALL BE EMBEDDED 1 FOOT MINIMUM BELOW GROUND AND BACKFILLED. IT SHALL BE SECURELY FASTENED TO THE STAKES AND FRAME.
DATE:
BY:
TOWN ASSESSOR
6.
A 2" x 4" WOOD FRAME SHALL BE COMPLETED AROUND THE CREST OF THE FABRIC FOR OVER FLOW STABILITY.
MAXIMUN DRAINAGE AREA 1 ACRE
BY:
FILTER FABRIC DROP INLET PROTECTION DETAIL
FIRE MARSHAL
PROJECT MANAGER
20
80
40
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
160
( IN FEET ) 1 inch = 40 ft. NO.
DATE
REVISION
BY
CHKD.
APVLS.
PR
0 9 6 1 84
OFE
AL S S I ON
Civil Engineering
DRAWN BY
ER
0
C
HA
W.T.A. J.S.F. TOPO/BASE
Landscape Architecture
G.L.R.
GRADING SECTION 2A PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
1"=40'
BELLA TERRA SUBDIVISION SECTION 2
TITLE OF DRAWING
Land Surveying
BOUNDARY
I NE
40
TE EL O R I T Y
NG
NOT TO SCALE
GRAPHIC SCALE
TITLE OF PROJECT
W.T.A.
OF NEW
ED
NOT TO SCALE
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
NS
BIO RETENTION DETAIL
STABILIZED CONSTRUCTION ENTRANCE DETAIL
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
E
360.5
24" MAX @ CENTER
347
H
361.0
347
RK O IE
366.0
1
8" MINIMUM
L I CE
LOT 205 - 208
C
4'MIN.
CONSTRUCTION SPECIFICATIONS
347
NOT TO SCALE
BIORETENTION PLANTING SOIL AND MULCH SPECIFICATIONS ARE PER APPENDIX H OF NYSSWDM
B (T.G.)
3.
4.
MULCH LAYER SPECIFICATIONS THE MULCH LAYER SHOULD BE STANDARD LANDSCAPE STYLE, SINGLE OR DOUBLE SHREDDED HARDWOOD MULCH OR CHIPS. THE MULCH LAYER SHOULD BE WELL AGED (STOCKPILED OR STORED FOR AT LEAST 12 MONTHS), UNIFORM IN COLOR, AND FREE OF OTHER MATERIALS, SUCH AS WEED SEEDS, SOIL, ROOTS, ETC. THE MULCH SHOULD BE APPLIED MAXIMUM DEPTH OF THREE INCHES. GRASS CLIPPINGS SHOULD NOT BE USED FOR MULCH MATERIALS.
A
1
TOWN ENGINEER
GATHER EXCESS AT CORNERS
F.F.=348.5
2
CONSTRUCTION SPECIFICATIONS
2.
BIO RETENTION AREA
2
TRAPEZOIDAL CROSS-SECTION
EX. PAVE.
PLANTING SOILS SPECIFICATIONS THE PLANTING SOIL SHOULD BE A SANDY LOAM, LOAMY SAND, LOAM (USDA), OR A LOAM/SAND MIX (SHOULD CONTAIN 50% SAND AND 50% TOPSOIL WITH AN ORGANIC CONTENT OF 5%, BY VOLUME). A PERMEABILITY OF AT LEAST 1.0 FEET PER DAY (0.5"/HR) IS REQUIRED. THE SOIL SHOULD BE FREE OF STONES, STUMPS, ROOTS, OR OTHER WOODY MATERIAL OVER 1" IN DIAMETER, BRUSH OR SEED FROM NOXIOUS WEEDS. PLACEMENT OF THE PLANTING SOIL SHOULD BE IN LIFTS OF 6" TO 8", LOOSELY COMPACTED.
2 4
FILTER FABRIC
TYPICAL PROFILE
1 2
10' MIN
PLAN VIEW
PERFORATED PIPE IN GRAVEL (SEE UTILITY PLAN)
1
BY:
HEIGHT OF FILTER = 16" MINIMUM
SEE NOTE 2
CUTOFF TRENCH DESIGN BOTTOM
B
346
A
VARIES
SECTION A-A 2'
VARIES SEE NOTE 4
ELEV=C
347
1.5' MIN.
C/L
100' MINIMUM FOR ACCESS TO COUNTY OR STATE ROADS, OTHERWISE - 50' MIN.
347
FILTER FABRIC
APPROVALS
TO CENTER)
C
3
FREEBOARD
5' MAX. (CENTER
ST
1
WATER QUALITY
346
BURIED FABRIC FRAME
20' WIDE UTILITY EASEMENT
9"MIN.
TRENCH TO BE PERPENDICULAR TO OVERLAND FLOW
10' MIN
ELEV=B
W FLO AND L R OVE
DROP INLET WITH GATE
MI
TYPICAL SECTION
A
345
346
20" MIN.
FILTER CLOTH
PROFILE
PROP. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION PROP. GUTTER AND CATCH BASIN
346
16" MIN.
SEE CA120 AND CA121
TOE
PROP. WATER MAIN, GATE VALVE & HYDRANT PROP. SANITARY SEWER & MANHOLE
2"X4" WOOD FRAME
INLET WITH TOP OF GRATE AND INVERT INFORMATION. (SEE PLAN VIEW)
CREST 24" MAX @ CENTER
H
E
B
10' MIN
PERFORATED PIPE IN 4" GRAVEL JACKET
SLOP
NOT TO SCALE
MOUNTABLE BERM OPTIONAL
6" MIN.
SAME ELEVATION
STONE BERM DROP INLET PROTECTION
C/L
100' MINIMUM FOR ACCESS TO COUNTY OR STATE ROADS, OTHERWISE - 50' MIN.
345
A CUTOFF TRENCH 18" WIDE 6" DEEP
Y
346
X
W
FILTER FABRIC - MIRAFI 14ON OR APPROVED EQUAL
SLOPE (FT/FT)
O W
ELEV=C
PLANTING SOIL (DEPTH VARIES)
REFER TO GOVERNING AGENCY FOR INLET SPECIFICATIONS
TEMP. SEDIMENTATION BUILDUP. CONTRACTOR SHALL REMOVE AS NECESSARY
FL
ELEV=B=T.G.
ELEV=B 6"-12" PONDING 3" MULCH
W
FL O
X=
SPACING VARIES
H (Ft)
H
#1 & #2 CRUSHED STONE
TYPICAL PLAN VIEW
D
3' MIN.
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA120 SHEET 5 OF 9
LOD
SHALLO
N
LOD
SALT ROAD
378
4 37
LOT 121
LOD LOD
380
381
LOD
379
LOD
379
LOD
378
LOD
377
LOD LOD
LOD
376 377
LOD
374 LOD
373 LOD
372
371
SF
27+00
LOD
SILT FENCE TYP.
1
37
FUTURE SECTIONS OF BELLA TERRA SUBDIVISION
372
REMAINING LANDS SALT ROAD (ZONED: LMR)
N/F 800 PHILLIPS ROAD LLC 1574 SISTINE WAY T.A. # 065.02-4-55
374
375 LOD
SF
9 370
372
SF
VERDE WAY (60.0' WIDE R.O.W.)
36
CHECK DAMS TYP.
REMAINING LANDS 83.213 ACRES FUTURE BELLA TERRA SUBDIVISION
N/F 800 PHILLIPS ROAD LLC 1575 SISTINE WAY T.A. # 065.02-4-21
8
36
3
28+00
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
WOODS
377
LOSF D 36
LOD
37
SF
7
36 6
S CONC. HEADWALL
5
SF
SF LOD
DB-15A RIM=371.5 S-12.1 RIM=371.5
D SF S
36
LOD
GARAGE ELEV. = 379.2
376
8
GV
(60.0'
36
APPROXIMATE LOCATION TOWN LOT 12
SISTE
371
APPROXIMATE LOCATION TOWN LOT 14
NE W AY WIDE R.O.W .)
S
375
371
S
RIM=367.53
370
EDGE OF BRUSH / HEDGEROW
SF LOD
SF LOD
364
GARA ELEV GE . = 37 6.2
369 37
0 RIM=366.03 RIM=365.71
D
LOD
364
378
SF RIM=365.87
SF LOD
SFLOD
4 36
SF
TG=364.26
377
LOD
LOD
D
SFLOD
SF
5 36
RIM=365.16
SFLOD
SF LOD
365
3 36
TG=364.21
SFLOD
365
366
LOT 120
367
LOD
367
368
SFLOD
369
SF LOD
LOD
SF LIMITS OF TOPSOIL PILE
37 5
37 4
LOD
LOD
370
369
LOD
LOD
SF
366
N/F 65 800 PHILLIPS ROAD 3 LLC 1577 SISTINE WAY T.A. # 065.02-4-20
LOT 154
SF OD L
366
LOD
LOT 153
N/F 800 PHILLIPS ROAD LLC 1576 SISTINE WAY T.A. # 065.02-4-54
367
369
368
SF LOD
SF D LO
371
LOD
SF
SF
370
368
SF OD L
LIMITS OF TOPSOIL PILE
6
1
LOT 254
LOT 251
LOD
D LO
372
LOT 250
N/F 800 PHILLIPS ROAD LLC T.A # 065.02-4-19
N/F 800 PHILLIPS ROAD LLC 1578 SISTINE WAY T.A. # 065.02-4-53
SF
369
LOT 152
6
LOT 260
369
37
LOD
GARAGE GARAGE ELEV. = 369.9ELEV. = 369.9
5
37
SF
367
LOT 253
GARAGE371.2 E G A R ELEV. = GA 371.2 ELEV. = LOT 252
STA 0+00 BELLORA WAY EQUALS STA 4+56.15 VERDE WAY
370
.2 AGE GARV. = 371 E EL
AGE .2 GARV. = 371 E EL
367
LOT 119
GARAGE ELEV. = 372.9
LOT 255 370
TG=366.56
LOT 249
LOT 259
LOT 229
37
1
LOD
LOT 258
LOT 257
LOT 256
GARAGE ELEV. = 372.9
376
37
DB-10.2 TG=369.20
SF
GARAGE ELEV. = 372.2
GARAGE ELEV. = 372.2
371
GE GARA. = 371.2 ELEV
GE GARA. = 371.2 V ELE
X
LOD
X
23+00
LOD
8+00
N/F 800 PHILLIPS ROAD LLC 1580 SISTINE WAY T.A. # 065.02-4-52
36
371
376
4 37
370
H.P. STA 6+67.10 ELE 370.65
X
369
SF
X
6+00
L.P. STA 5+30.42 DB-12.2 ELE 369.90 TG=369.54
X
LO D
7+00
X
X
372
X
D
LOT 228
LOT 230
X
X
9+00
STABILIZED CONSTRUCTION ENTRANCE
2
X
TG=367.29
X
0+00
DB-14.2 TG=370.90
372.45
D X
DB-10.1 TG=370.25
X X
LOT 151
RIM=369.56
10+00
DB-15 RIM=374.1
37
X
LOD
X X
N/F 800 PHILLIPS ROAD LLC T.A. # 065.02-4-51
3
X
5+00
RIM=369.71
S
373
1+00
X
X
370
368.20
10+2
2+00
3+00
X
S
S
368
371
X
X
D
X
X
SF LOD
373
DB-14.1 TG=370.90
X
D
X
X
X
WAY BELLORA R.O.W.) (600.0' WIDE 0
4+
S-9 RIM=370.6
D X
DB-12 RIM=369.8
DB-11 RIM=370.5
D
S-12 RIM=374.5
X
RIM=369.01
GARAGE ELEV. = 370.9
GARAGE ELEV. = 370.9
GARAGE GARAGE ELEV. = 370.2 ELEV. = 370.2
371
LOD
BE (60 LLOR .0 ' WI A W A DE R .O Y .W .)
S
DB-12.1 TG=369.54
SF
S
D
X
X
RIM=368.23
374
S D X
X
X
INLET PROTECTION TYP.
DB-14 RIM=371.2
X
REMAINING LANDS SALT ROAD (ZONED: LMR)
375
GARAGE ELEV. = 371.1
DB-13 RIM=370.1 S-10 RIM=370.2
X
LOT 243
S-11 RIM=371.4
372
GARAGE ELEV. = 371.1
DB-15.2 TG=373.90 DB-15.1 TG=373.90
N/F 800 PHILLIPS ROAD LLC T.A. # 65.020-01-040.221 LIBER 10731 PAGE 75 REMAINDER OF LIBER 362 OF MAPS PAGE 43
7
LOT 227
378
X
LOT 244
LOT 245
LOT 246
3
GARAGE ELEV. = 369.9
37
RIM=367.99
GARAGE ELEV. = 371.2
2
LOD
GARAGE ELEV. = 369.9
GARAGE ELEV. = 373.1
37
SF
LOT 247
LOT 248
GARAGE ELEV. = 371.2
GARAGE ELEV. = 373.1
GARAGE ELEV. = 372.2
GARAGE ELEV. = 372.2
24+00
LOD
SF LOD
LOT 240
LOT 242
LOT 234
LOT 239
369
LOT 241
LOT 233
LOT 235
LOT 236
LOT 237
LOT 238
369
LOT 118
GARAGE ELEV. = 381.2
37
3 37
X
H.P. 369.5
370
378
X X
370
0 37
X
LOD
N/F 800 PHILLIPS ROAD LLC 1594 BELLORA WAY T.A. # 065.02-4-18
LOT 226
378
LOD
LOD
369
X
SF
H.P. 370.5
379
DB-14A TG=369.9
371
X
X
379
6 37
X
X
LOT 225
5 37
X
X
DB-10A TG=367.4
377
LOD
368
H.P. 373.0
9 36
X
9
37
26+00
LOD
SF
372
380
LOT 232
DB-12A END SECTION INV=368.00
25+00
LOD
TG=365.77
VERDE WAY (60.0' WIDE R.O.W.)
GARAGE ELEV. = 379.5
S
LOD LOD
X
X
GARAGE GARAGE ELEV. = 378.1 ELEV. = 378.1
37 0
LOD
369
S
LOD
INLET PROTECTION TYP.
X
SILT FENCE TYP.
N/F 800 PHILLIPS ROAD LLC 1592 BELLORA WAY T.A. # 065.02-4-17
S
GARAGE ELEV. = 379.5
1 37
LOD
375
LOD
S
LOD
4
X
D
380
381
GARAGE ELEV. = 381.2
D
G
RGE 91
LOD
37
373
S-13 RIM=379.4
22+00
LOD
370
6
X
378
380
Hs 18
LOT 231
377
375 37
369
Lt 1
Aa 3
Sm 4
DB-16 RIM=379.3
379
378 X
GARAGE ELEV. = 379.2
G
S
LOD
Lt 1
Aa 3
371
Aa 3
LANDSCAPED BERM. REFER TO SECTION 1 APPROVAL PLANS.
Pm 3
Pm Pm 5 3
Hs 18
Lt 1
Cf 8
379
G
RIM=366.72
LOD
Pm 3
Cf 8
378
Cf 8 DB-16.1 TG=377.00
GARA ELEV GE . = 37 6.2
G
3
D
LOD
LOD
LOD
377
Wa 17
LOD
376
D
G
37 LOD
SF
TG=365.38
Pm 5
Lt 1
Aa 3
Pm 3
Lt 1
375
375 Lt 1
371
Aa 3
374
Pm 3
374
372
372
Sm 4
Fi 7
RIM=378.18
RIM=380.62
X
Sm 9
Fi 7
Fi 7
Aa 3
Sm 9
Lt 3
X
RIM=369.87
RIM=367.68
Ar 3
Sm 9
Fi 7
Fi 7
Ar 3
Aa 3
Sm 9
Fi 7
Fi 7
Wa 17
Hs 17
LO
15" PVC
Ar 3
Fi 7
Ar 3 373
Bx 5
Cf 8
21+00
Ar 3
Sm 9
Fi 7
RIM=371.82
Fi 7
7
3
Pm 3
Fi 7
LO D
68
RIM=371.20
37
6
2 37
1 37
371
Hs 17
37
5 37
37 4
37 3
Bx 5
LOD
G
369
RIM=370.02
381
GRID
0 38
9 37
6
5
STABILIZED CONSTRUCTION ENTRANCE
7
4
3
8
37
(66' WIDE R.O.W.)
COUNTY ROAD 6
37
37
37 372
37
37
28+38
MILANO TRAIL (60.0' WIDE R.O.W.)
RIM=365.03
WILDFLOWER PLANTING GUIDE QTY KEY BOTANICAL NAME DECIDUOUS TREES 21 Aa AMELACHIER ARBOREA 15 Ar ACER RUBRUM ‘OCTOBER GLORY’ 6 Lt LIRIODONDENDRON TULIPIFERA EVERGREEN TREES 25 Pm PSEUDOTSUGA MENZIESII SHRUBS 10 Bx BUXUS X. GREEN MOUNTAIN 32 Cf CALAMAGROSTIS X. ACUTIFLORA 77 Fi FORSYTHIA X INTERMEDIA ‘SPRING GLORY’ 70 Hs HEMEROCALLS X. ‘HAPPY RETURNS’ 53 Sm SYRINGA MEYERI ‘PALIBIN’ 34 Wa WEIGELA FLORIDA ‘WINE AND ROSES’
THE APPLICATION OF AN APPROVED HERBICIDE, SUCH AS GLYPHOSATE (ROUNDUP® OR RODEO®), IS THE MOST COMMON AND LEAST TIME-INTENSIVE PROTOCOL FOR CONTROLLING EXISTING VEGETATION. HERBICIDES ARE MOST EFFECTIVE ON ACTIVELY ROWING PLANT TISSUES; THEREFORE, THEY ARE VERY EFFECTIVE ON NEW GROWTH IN THE SPRING. SPRAYING SHOULD BEGIN WHEN GROWTH IS APPROXIMATELY 6” HIGH. ONE TO TWO WEEKS LATER, A FOLLOW-UP APPLICATION OF SPRAY MAY BE MADE TO ADDRESS SKIPS OR PERSISTENT SPECIES. IF SUBSTANTIAL PLANT TISSUES REMAIN ON THE SURFACE FOLLOWING A FULL KILL BY HERBICIDES, A CLOSE MOWING, TILLAGE OR BURNING MAY BE NECESSARY TO ACHIEVE GOOD SEED-TO-SOIL CONTACT. FIRST GROWING SEASON
5’ HT/3’ SP. 6’HT/2’SP. 8’ HT/6’ SP. 24” HT/SP. 5’-7’ SP. 4’-5’ HT/SP.
EXIST. WATER MAIN, GATE VALVE & HYDRANT EXIST. SANITARY SEWER & MANHOLE
W
SP.=SPREAD HT.=HEIGHT
NO.#=GALLON SIZE CONT.=CONTAINER
EXIST. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION
BR.=BARE ROOT
1.5' MAX.
H
W
STAKE
Y
PROP. WATER MAIN, GATE VALVE & HYDRANT PROP. SANITARY SEWER & MANHOLE PROP. DRAINAGE SEWER, FIELD INLET INLET MANHOLE, M.H., & END SECTION
A CUTOFF TRENCH 18" WIDE 6" DEEP
FILTER CLOTH
SECTION VIEW
C/L
PROFILE
346
A
FREEBOARD
EXISTING PAVEMENT
346
10' MIN
2'
1
1 2
2 4
10' MIN
2 4'MIN.
1
1 FILTER FABRIC
1 1
1
ALL TREES, BRUSH, STUMPS, OBSTRUCTIONS, AND OTHER OBJECTIONABLE MATERIAL SHALL BE REMOVED AND DISPOSED OF SO AS NOT TO INTERFERE WITH THE PROPER FUNCTIONING OF THE SEDIMENTATION TRENCH.
AS REQUIRED, 100 FT. MIN. FOR ACCESS TO COUNTY OR STATE ROADS, OTHERWISE, 50 FT. (EXCEPT ON SINGLE RESIDENCE LOT WHERE A 30 FT. MINIMUM LENGTH SHALL APPLY.
3.
4.
SECTION B-B
RIGHT-OF-WAY LINE
347
THE SEDIMENTATION TRENCH SHALL BE EXCAVATED OR SHAPED TO LINE, GRADE, AND CROSS SECTION AS REQUIRED TO MEET THE CRITERIA SPECIFIED HEREIN, AND BE FREE OF BANK PROJECTIONS OR OTHER IRREGULARITIES WHICH WILL IMPEDE NORMAL FLOW. FILLS SHALL BE COMPACTED AS NEEDED TO PREVENT UNEQUAL SETTLEMENT THAT WOULD CAUSE DAMAGE TO THE TRENCH. STABILIZATION SHALL BE DONE ACCORDING TO THE APPROPRIATE STANDARD AND SPECIFICATIONS FOR VEGETATIVE PRACTICES.
2.
3. 4. 5.
STONE WILL BE PLACED ON A FILTER FABRIC FOUNDATION TO THE LINES, GRADES AND LOCATIONS SHOWN IN THE PLAN. SET SPACING OF CHECK DAMS TO ASSUME THAT THE ELEVATIONS OF THE CREST OF THE DOWNSTREAM DAM IS AT THE SAME ELEVATION OF THE TOE OF THE UPSTREAM DAM. EXTEND THE STONE A MINIMUM OF 1.5 FEET BEYOND THE DITCH BANKS TO PREVENT CUTTING AROUND THE DAM. PROTECT THE CHANNEL DOWNSTREAM OF THE LOWEST CHECK DAM FROM SCOUR AND EROSION WITH STONE OR LINER AS APPROPRIATE. ENSURE THAT CHANNEL APPURTENANCES SUCH AS CULVERT ENTRANCES BELOW CHECK DAMS ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONE. MAXIMUM DRAINAGE AREA 2 ACRES.
SEDEMENTATION TRENCH DETAIL
CHECK DAM DETAIL
NOT TO SCALE
NOT TO SCALE
ROAD CENTERLINE
STORM SEWER
1. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION.
GUTTERS
2. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER, THEY SHALL BE OVERLAPPED BY 6" AND FOLDED.
RIGHT-OF-WAY LINE
NOTES:
347
347
1. SEE 225-44 OF THE TOWN CODE ZONING ORDINANCE FOR MIN. HEIGHT OF FIRST FLOOR ELEVATIONS WITH RELATION TO THE ELEVATION AT THE ROAD CROWN. 2. WHEN BUILT-IN AREA IS NOT ON STORM SEWER RUN, SPLASH BLOCKS MAY BE PERMITTED.
PERSPECTIVE VIEW CONSTRUCTION NOTES:
MANHOLE (SEE PLAN VIEW FOR INVERTS)
CONSTRUCTION SPECIFICATIONS 1.
TOWN ENGINEER
GATHER EXCESS AT CORNERS
8" MINIMUM
347
18"
EX. PAVE.
2.
347
24" MAX @ CENTER
6"
BY:
HEIGHT OF FILTER = 16" MINIMUM
CONSTRUCTION SPECIFICATIONS
2% MIN. SLOPE
CONSTRUCTION SPECIFICATIONS
CONSTRUCTION SPECIFICATIONS AND NOTES
346
347
WIDTH
TRAPEZOIDAL CROSS-SECTION
1.
347
F.F.=348.5
2
1
APPROVALS
TO CENTER)
SEE NOTE 2
CUTOFF TRENCH DESIGN BOTTOM
B
BURIED FABRIC FRAME
1.5' MIN.
SECTION A-A
DROP INLET WITH GATE 5' MAX. (CENTER
347
FILTER FABRIC
345
346 20' WIDE UTILITY EASEMENT
9"MIN.
TRENCH TO BE PERPENDICULAR TO OVERLAND FLOW
C/L
PLAN VIEW
H
E
2"X4" WOOD FRAME
INLET WITH TOP OF GRATE AND INVERT INFORMATION. (SEE PLAN VIEW)
CREST 24" MAX @ CENTER
B
W FLO AND L R OVE
100' MINIMUM FOR ACCESS TO COUNTY OR STATE ROADS, OTHERWISE - 50' MIN.
SLOP
TOE
NOT TO SCALE
MOUNTABLE BERM OPTIONAL
6" MIN.
345
SAME ELEVATION
STONE BERM DROP INLET PROTECTION
100' MINIMUM FOR ACCESS TO COUNTY OR STATE ROADS, OTHERWISE - 50' MIN.
346
X
1' MIN.
REFER TO GOVERNING AGENCY FOR INLET SPECIFICATIONS
TEMP. SEDIMENTATION BUILDUP. CONTRACTOR SHALL REMOVE AS NECESSARY
SPACING VARIES
H (Ft) SLOPE (FT/FT)
F.F.=348.5
EXISTING GRADE PROPOSED GRADE FLOW DIRECTION EASEMENT LINE SPLASH BLOCKS SUMP PUMP FIRST FLOOR ELEV.
3. MAINTENANCE SHALL BE PERFORMED AS NEEDED, AND MATERIAL REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE.
SECTION VIEW
2. 36" MIN. FENCE POSTS, DRIVEN 16" MIN. INTO THE GROUND.
UNDIST. GROUND
FLOW EMBED FILTER CLOTH MIN. 8" INTO GROUND
POST MATERIAL:
STEEL, EITHER T OR U TYPE, OR 2" HARDWOOD.
FILTER CLOTH:
FILTER X, MIRAFI 100X, STABILINKA T140N, OR EQUAL.
PREFABRICATED UNIT:
GEOFAB, ENVIROFENCE, OR APPROVED EQUAL.
TYPICAL LOT GRADING DETAIL
FILTER FABRIC SILT FENCING DETAIL
NOT TO SCALE
NOT TO SCALE
BY:
CUT FABRIC FROM A CONTINUOUS ROLL TO ELIMINATE JOINTS. IF JOINTS ARE NEEDED THEY WILL BE OVERLAPPED TO THE NEXT STAKE.
PLANNING BOARD CHAIRPERSON
1. FILTER FABRIC SHALL HAVE AN EOS OF 40-85. BURLAP MAY BE USED FOR SHORT TERM APPLICATIONS.
O W
X=
PROP. GUTTER AND CATCH BASIN
3' MIN.
BY:
TOWN HIGHWAY SUPERINTENDENT
3.
STAKE MATERIALS WILL BE STANDARD 2" x 4" WOOD OR EQUIVALENT. METAL WITH A MINIMUM LENGTH OF 3 FEET.
4.
SPACE STAKES EVENLY AROUND INLET 3 FEET APART AND DRIVE A MINIMUM 18 BY: WEBSTER SEWER DISTRICT INCHES DEEP. SPANS GREATER THAN 3 FEET MAY BE BRIDGED WITH THE USE OF WIRE MESH BEHIND THE FILTER FABRIC FOR SUPPORT.
5.
FABRIC SHALL BE EMBEDDED 1 FOOT MINIMUM BELOW GROUND AND BACKFILLED. IT SHALL BE SECURELY FASTENED TO THE STAKES AND FRAME.
DATE:
BY:
TOWN ASSESSOR
6.
A 2" x 4" WOOD FRAME SHALL BE COMPLETED AROUND THE CREST OF THE FABRIC FOR OVER FLOW STABILITY.
MAXIMUN DRAINAGE AREA 1 ACRE
BY:
FILTER FABRIC DROP INLET PROTECTION DETAIL
FIRE MARSHAL
NOT TO SCALE PROJECT MANAGER
( IN FEET ) 1 inch = 40 ft. NO.
DATE
REVISION
BY
CHKD.
APVLS.
ED
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
160
ER
80
40
0 9 6 1 84
PR OFE
SS I
L O NA
Civil Engineering
DRAWN BY
W.T.A./E.L.O. J.S.F. TOPO/BASE
Landscape Architecture
G.L.R.
GRADING SECTION 2B PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
1"=40'
BELLA TERRA SUBDIVISION SECTION 2
TITLE OF DRAWING
Land Surveying
BOUNDARY
I NE
20
C
HA
NG
0
H
40
TE EL O R I T Y
RK O IE
GRAPHIC SCALE
TITLE OF PROJECT
W.T.A.
OF NEW
NS
NOT TO SCALE
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
L I CE
STABILIZED CONSTRUCTION ENTRANCE DETAIL
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
E
A ONE YEAR GUARANTEE SHALL BE PROVIDED ON ALL PLANT MATERIALS FROM THE DATE OF PROVISIONAL ACCEPTANCE.
CONT CONT CONT CONT BB CONT
A
9.
MULCH ALL TREES, SHRUBS AND ANNUAL PLANTING. SEE DETAIL DRAWING NO. CA501 (SHEET 10 OF 10).
#5 #2 #7 #2 30"-36" HT #3
C
8.
GREEN MOUNTAIN BOXWOOD FORESTER’S FEATHER REED GRASS SPRING GLORY FORSYTHIA HAPPY RETURNS DAYLILLY DWARF KOREAN LILAC WINE AND ROSES WEIGELA
12"
#1 & #2 CRUSHED STONE
4 PARTS TOPSOIL, 1 PART PEAT MOSS, 1/2 PART WELL ROTTED MANURE AND 10 LBS. 5-10-5 PLANTING FERTILIZER MIXED THOROUGHLY PER CUBIC YARD. STAKE TREES IMMEDIATELY AFTER PLANTING. REMOVE AFTER ONE YEAR.
40’-80’ HT/
ST
7.
BB
MI
6.
SHOULD LOCATION OF TREES BE WITHIN 20' OF OVERHEAD WIRES, RELOCATE SAID TREES TO A MINIMUM OF 20' FROM WIRES.
6’-7’
ALL ROADWAY WEEPS SHALL HAVE UNDERDRAIN THE FULL LENGTH OF THE ROAD.
20" MIN.
5.
SHOULD LOCATION OF TREES BE WITHIN 5' OF UNDERGROUND UTILITIES, RELOCATE SAID TREES TO A MINIMUM OF 5' FROM ROOTBALL TO UTILITIES.
DOUGLAS FIR
2.
FABRIC
10' MIN
4.
THE CONTRACTOR IS HEREBY NOTIFIED THAT UNDERGROUND UTILITIES EXIST AND HE SHOULD SECURE CURRENT UTILITY PLANS BEFORE COMMENCING WORK.
15’-25’ HT./SP. 25’-35’ SP. 60’-90’ HT/ 30’-50’ SP.
20' MIN. WIDTH STORM DRAINAGE EASEMENT TO THE TOWN OF WEBSTER
VARIES SEE NOTE 4
3.
BB BB BB
3:1 SLOPE
12" MIN. 24" MAX.
ALL PLANTS SHALL MEET OR EXCEED THE MINIMUM REQUIREMENTS AS NOTED IN THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK BY THE AMERICAN ASSOCIATION OF NURSERYMEN, ANSI Z60.I. THE CONTRACTOR SHALL STAKEOUT ALL PLANTINGS FOR OWNER REPRESENTATIVE APPROVAL PRIOR TO BEGINNING WORK.
1.75”- 2.25” 2"-2.5" CAL 2”- 3” CAL.
2:1 SLOPE
GENERAL MAINTENANCE · IN ADDITION TO STRUCTURAL MAINTENANCE, SILTATION NEEDS TO BE REMOVED AS NEEDED. CLOSE MOWING OR EXTENSIVE CHEMICAL USE IS NOT CONDUCIVE TO WATER QUALITY IMPROVEMENT AND WILDLIFE HABITAT.
2.
SERVICEBERRY OCTOBER GLORY MAPLE TULIP TREE
SECTION/PARCEL BOUNDARY PROPOSED RIGHT-OF-WAY PROPOSED LOT LINE PROPOSED EASEMENT LINE MIN. BUILDING SETBACK CENTER LINE EXIST. ADJOINING PROPERTY LINE EXIST. EASEMENT LINE EXIST. RIGHT-OF-WAY LINE EXIST. EDGE OF PAVEMENT
D
BB=BALLED & BURLAPPED CAL.=CALIPER IN INCHES
SPECIAL CIRCUMSTANCES · IF YOU NOTICE A HEAVY INFESTATION OF RAGWEED OR FOXTAIL IN THE SECOND GROWING SEASON, TRIM THE MEADOW TO A HEIGHT OF 8”. IF BIOENGINEERING OR CONTAINERIZED WOODY MATERIALS WERE USED, TRIMMING SHOULD BE ABOVE OR AROUND NEW GROWTH OF THE PLANTS. TRIMMING SHOULD CEASE AFTER MID-SEPTEMBER.
LANDSCAPE NOTES
MATURE SIZE
ABBREVIATIONS:
SECOND GROWING SEASON · PRIOR TO NEW SPRING GROWTH REACHING A HEIGHT OF 2” (E.G., SHORTLY AFTER FORSYTHIA OR REDBUD BLOOMS), · TRIM ANY MATERIAL STANDING FROM THE PREVIOUS YEAR CLOSE TO THE GROUND (APPROXIMATELY 2”). THIS WILL ALLOW THE SOIL TO WARM MORE QUICKLY, WHICH WILL STIMULATE THE EMERGENCE AND GROWTH OF NATIVE SEEDLINGS. IT WILL ALSO REDUCE THE LIKELIHOOD OF THE MEADOW BEING INVADED BY SHRUBS. · IF BIOENGINEERING OR CONTAINERIZED WOODY MATERIALS WERE USED ON THE SITE OR SEED OF SHRUBS/TREES WERE PART OF THE MIX, THE SITE SHOULD NOT BE TRIMMED AFTER THE ESTABLISHMENT YEAR. · PROBLEM WEEDS SHOULD BE HAND PULLED OR SPOT-SPRAYED.
1.
ROOT NOTE
FL
·
SIZE
DRIVEWAYS ARE NOT PERMITTED 1. ALL CROSSOVER PIPES SHALL BE PERFORATED HDPE. OVER MANHOLES, CLEAN-OUTS, VALVES AND CATCH BASINS
W
·
WHENEVER CANOPY (OVERALL VEGETATION) REACHES A HEIGHT OF 18”- TRIM THE MEADOW TO A HEIGHT OF 8” (NOTE: A LAWN MOWER IS NOT RECOMMENDED AS THE MOWER HEIGHT WILL BE TOO LOW AND NATIVE SEEDLINGS WILL BE KILLED). THIS WILL REDUCE COMPETITION BY FAST-GROWING WEEDS FOR SUNLIGHT, WATER AND NUTRIENTS NEEDED BY SLOW-GROWING PERENNIAL NATIVES. MOWING SHOULD CEASE BY MID-SEPTEMBER. FOR SEEDINGS OF ANNUAL WILDFLOWER MIXES OR ANNUAL & PERENNIAL WILDFLOWER MIXES, PROBLEM WEEDS SHOULD BE REMOVED. PROBLEM WEEDS SHOULD BE REMOVED OR SPOT SPRAYED WITH APPROVED HERBICIDES (SUCH AS ROUNDUP® OR RODEO®).
COMMON NAME
FL O
·
LEGEND
NOTES:
PLANT SCHEDULE
SITE PREPARATION (PER WWW.ERNSTSEEDS.COM)
16" MIN.
D
LOT 155
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA121
SHEET 6 OF 9
EXISTING GRADE PROPOSED CENTERLINE FINISHED GRADE
GRADE BREAK STA = 10+95.71 ELEV = 371.765
375 DC-9: 5' DIA. M.H. STA. 7+94 RIM=370.0 INV. IN (18" FROM DC-10)=363.96 INV. OUT (18" TO DC-8)=363.86
70'-18" HDPE @ 0.91%
370 0.78% PE @ 0.92% 185'-18" HD
88'-12" HDPE @ 0.46% 65'-12" HDPE @ 1.00%
365
7% 112'-18" HDPE @ 0.5
2% 154'-18" HDPE @ 0.5
1.32%
365 177'-8" PVC @ 0.85%
264'-24" HDPE @ 0.43%
114'-8" PVC @ 0.79%
P.V.I. (NO VERT. CURVE) STA.= 15+70.58 ELEV.=366.34
155'-8" PVC @ 0.85%
360 192'-12" HDPE @ 1.46%
" PVC 102'-8
355
9% @ 1.9
263'-8" PVC @ 0.82% 69'-8" PVC @ 0.68%
114'-8" PVC @ 0.40%
350
EXISTING MANHOLE STA. 1+09 RIM=364.02 INV IN=353.42 (8") INV OUT=353.32 (8") EXISTING MANHOLE STA. 1+19 RIM=362.92 INV IN=358.33 (12") INV OUT=358.23 (12")
345 0+00
DC-6: 5' DIA. M.H. STA. 3+15 RIM=365.8 S-1.5: 4' DIA. M.H. STA. 2+22 INV. IN (12" FROM DC-6A)=361.60 RIM=365.1 DC-6A: 5' DIA. M.H. STA. 2+28INV. IN (24" FROM DC-7)=361.10 INV. IN (8" FROM S-1.6)=353.98 RIM=365.1 INV. IN (12" FROM DC-6.1)=358.65 INV. OUT (8" TO S-1.4)=353.88 INV. OUT (12" TO DC-6)=362.00 INV. OUT (24" TO DC-5)=361.00
1+00
S-1.8: 4' DIA. M.H. STA. 6+51 RIM=368.5 INV. IN (8" FROM S-1.9)=358.81 INV. OUT (8" TO S-1.7)=358.79
S-1.6: 4' DIA. M.H. STA. 3+22 DC-7: 5' DIA. M.H. STA. 5+77 RIM=366.1 RIM=368.1 INV. IN (8" FROM S-1.7)=356.10 INV. IN (18" FROM DC-8)=362.33 INV. OUT (8" TO S-1.5)=356.00 INV. OUT (24" TO DC-6)=362.23
188'-8" PVC @ 0.93%
2+00
P.V.I. (NO VERT. CURVE) STA.= 18+90.52 ELEV.=368.39
INV. OUT (12" TO DA-5.1)=358.98 DA-5.2: 5' DIA. M.H. STA. 1+84 RIM=364.2
DC-8: 5' DIA. M.H. STA. 6+47 RIM=368.4 INV. IN (18" FROM DC-9)=363.06 INV. IN (12" FROM DC-8.1)=365.08 INV. OUT (18" TO DC-7)=362.96
S-1.9: 4' DIA. M.H. STA. 7+98 RIM=370.1 INV. IN (8" FROM S-1.10)=360.16 INV. OUT (8" TO S-1.8)=360.14
P.V.I. (NO VERT. CURVE) STA.= 18+80.52 ELEV.=368.19
375
370
380
GRADE BREAK STA = 2+24.67 ELEV = 365.000
GRADE BREAK STA = 0+00.00 ELEV = 362.040
380
3+00
4+00
DC-10: 5' DIA. M.H. STA. 9+02 RIM=371.0 INV. IN (18" FROM DC-11)=364.69 INV. IN (12" FROM DC-10.1)=365.57 INV. IN (12" FROM DC10.1)=367.43 INV. OUT (18" TO DC-9)=364.59
S-1.7: 4' DIA. M.H. STA. 5+83 RIM=368.1 INV. IN (8" FROM S-1.8)=358.32 INV. OUT (8" TO S-1.6)=358.27
5+00
6+00
360
375
355
370
S-1.11: 4' DIA. M.H. STA. 10+73 RIM=372.1 INV. OUT (8" TO S-1.10)=362.71
DC-11: 5' DIA. M.H. STA. 10+80 RIM=372.1 INV. OUT (18" TO DC-10)=366.40
S-1.10: 4' DIA. M.H. STA. 9+06 RIM=371.1 INV. IN (8" FROM S-1.11)=361.21 INV. OUT (8" TO S-1.9)=361.06
375
P.V.I. (NO VERT. CURVE) STA.= 16+74.95 ELEV.=365.71
370
EXISTING GRADE
2.00%
1.21%
-0.61%
350
365
365 PROPOSED CENTERLINE FINISHED GRADE
7+00
8+00
9+00
345 10+96
10+00
360 15+71 16+00
TERRA VERDE WAY 2A PROFILE SCALE: HORIZ. 1"=50' VERT. 1"=5'
17+00
360 18+91
18+00
HORIZ. 1"=50' VERT. 1"=5'
370
370
PROPOSED PRECAST HEADWALL FINISHED GRADE
PROPOSED PRECAST HEADWALL
365
380
375
FUTURE CENTERLINE GRADE
P.V.I. (NO VERT. CURVE) STA.= 20+50.27 ELEV.=380.15
P.V.I. (NO VERT. CURVE) STA.= 25+17.54 ELEV.=371.81
385
22+91.27 PVI ELEV: 378.41 K: 45.53 LVC: 100.00
22+41.27 BVCE: 378.77
390
23+41.27 EVCE: 376.95
390
365
PROPOSED CENTERLINE FINISHED GRADE
PROPOSED 4' X10' BOX CULVERT @ 0.50%
385
360
0.50%
0.95%
380 EXISTING GRADE
360
EX. DITCH PROFILE
-0.72%
0.49%
0.17%
0.35%
0.82%
-2.92%
375
0+00
1+00
1+65
STREAM CROSSING BOX CULVERT PROFILE 370
264'-12" HDPE @ 1.77%
196'-12" HDPE @ 0.40%
DB-16: 5' DIA. M.H. STA. 21+79 RIM=379.3 INV. IN (12" FROM DB-16.1)=373.00 INV. OUT (12" TO DB-15)=372.50
254'-8" PVC @ 1.87%
S-12: 4' DIA. M.H. STA. 24+35 RIM=374.5 INV. IN (8" FROM S-13)=364.55 INV. IN (8" FROM S-12.1)=364.55 INV. OUT (8" TO S-11)=364.45
DB-15: 5' DIA. M.H. STA. 24+40 RIM=374.1 INV. IN (12" FROM DB-16)=367.82 INV. IN (12" FROM DB-15A)=367.82 INV. IN (12" FROM DB-15.1)=367.82 INV. OUT (18" TO DB-14)=367.72
S-12.1: 4' DIA. M.H. STA. 26+44 RIM=371.5 INV. OUT (8" TO S-12)=365.37
355 28+38
28+00
27+00
26+00
25+00
24+00
23+00
22+00
360
355 20+00
21+00
375
TERRA VERDE WAY 2B PROFILE SCALE: HORIZ. 1"=50' VERT. 1"=5'
5+31.35 PVI ELEV: 369.74 K: 76.78 LVC: 100.71
4+81.00 BVCE: 370.06
EXISTING MANHOLE STA. 9+94 RIM=368.59 PROPOSED CENTERLINE INV IN=363.26 (30") FINISHED GRADE INV OUT=363.16 (30")
5+81.71 EVCE: 370.07
375
6+17.84 BVCE: 370.31
7+17.85 EVCE: 370.30
P.V.I. (NO VERT. CURVE) STA.= 10+23.42 ELEV.=368.20
6+67.84 PVI ELEV: 370.65 K: 73.74 LVC: 100.01
370
380
5+30.42 LOW PT ELEV: 369.90
6+67.10 HIGH PT ELEV: 370.48
370
P.V.I. (NO VERT. CURVE) STA.= 0+00.15 ELEV.=373.16
380
375 UTILITY POLE APPROXIMATLY 14.5 ' NORTH OF PROPOSE SEWER.
INV. OUT (8" TO S-10)=363.16 INV. IN (8" FROM S-12)=363.25 S-11: 4' DIA. M.H. STA. 2+76 RIM=371.4
EXISTING RG&E EASEMENT.
365
365
375
EXISTING GRADE
-0.64%
370
370
0.67%
360
-0.69%
154'-30" HDPE @ 0.40%
365
126'-30" HDPE @ 0.40%
360
299'-18" HDPE @ 0.40%
152'-24" HDPE @ 0.40%
110'-24" HDPE @ 0.40%
+/- 9' EXCAVATION
360
S-13: 4' DIA. M.H. STA. 21+84 RIM=379.4 INV. OUT (8" TO S-12)=369.30
+/- 8' EXCAVATION ADJACENT TO EXISTING UTILITY POLE
DB-15A: 5' DIA. M.H. STA. 26+38 RIM=371.5 INV. OUT (12" TO DB-15)=368.60
365
7.1' TO BOTTOM OF EXCAVATION
207'-8" PVC @ 0.40%
APPROXIMATE LOCATION OF BURIED ELECTRIC
365
VERTICAL SCALE 1" = 2.5' HORIZONTAL SCALE 1" = 1'
4.6' TO TOP OF SEWER
370
365
355 163'-8" PVC @ 0.40%
300'-8" PVC @ 0.40%
DB-12: 5' DIA. M.H. STA. 5+39 RIM=369.8 INV. IN (24" FROM DB-13)=365.27 DB-13: 5' DIA. M.H. STA. 4+31 DB-14: 5' DIA. M.H. STA. 2+81 INV. IN (12" FROM DB-12A)=366.00 RIM=370.1 RIM=371.2 DB-11: 5' DIA. M.H. STA. 6+66 INV. IN (12" FROM DB-12.1)=366.44 INV. IN (24" FROM DB-14)=365.81 INV. IN (18" FROM DB-15)=366.52 RIM=370.5 INV. IN (12" FROM DB-14A)=366.75 INV. IN (30" FROM DB-12)=364.67INV. OUT (30" TO DB-11)=365.17 INV. OUT (24" TO DB-12)=365.71 INV. IN (12" FROM DB-14.1)=367.90 INV. OUT (30" TO DB-10)=364.57 INV. OUT (24" TO DB-13)=366.42 S-10: 4' DIA. M.H. STA. 4+36 S-9: 4' DIA. M.H. STA. 6+72 RIM=370.2 RIM=370.6 INV. IN (8" FROM S-11)=362.50 INV. IN (8" FROM S-10)=361.46 INV. OUT (8" TO S-9)=362.40 INV. OUT (8" TO S-8)=361.36 236'-8" PVC @ 0.40%
5+00
4+00
3+00
2+00
TOWN ENGINEER
BY:
PLANNING BOARD CHAIRPERSON
350 0+00
1+00
BY:
TOWN HIGHWAY SUPERINTENDENT
HORIZ. 1"=50' VERT. 1"=5' BY:
WEBSTER SEWER DISTRICT
BY:
TOWN ASSESSOR
BY:
FIRE MARSHAL
PROJECT MANAGER
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
0
25
100
50
NO.
DATE
REVISION
BY
CHKD.
APVLS.
ED
( IN FEET ) 1 inch = 50 ft.
C
HA
NS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
200
H
50
TE EL O R I T Y
PR
0 9 6 1 84
OF E
AL S S I ON
Civil Engineering
DRAWN BY
RK O IE
GRAPHIC SCALE
TITLE OF PROJECT
W.T.A.
O F N EW
L I CE
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
ER
6+00
BY:
W.T.A.
TITLE OF DRAWING
J.S.F. TOPO/BASE
Landscape Architecture
G.L.R.
ROAD PROFILES PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
1"=50'
BELLA TERRA SUBDIVISION SECTION 2
Land Surveying
BOUNDARY
I NE
7+00
RG&E CROSSING PROFILE SCALE: HORIZ. 1"=50' VERT. 1"=5'
355
NG
8+00
350 1+77
E
9+00
EXISTING MANHOLE STA. 8+24 RIM=369.56 INV IN=363.96 (30") INV IN=363.96 (12") INV IN=363.96 (12") INV OUT=363.86 (30")
1+00
A
350 10+23 10+00
EXISTING MANHOLE STA. 8+30 RIM=369.71 INV IN=360.76 (8") INV OUT=360.66 (8")
350 0+00
C
355
APPROVALS
ST
153'-8" PVC @ 0.39%
260'-8" PVC @ 1.23%
360
355
MI
360
+/- 6' EXCAVATION
165'-30" HDPE @ 0.36%
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA300 SHEET 7 OF 9
19"
DISCHARGE STORM PIPE
B BOLT COMPACTED STONE ENCASEMENT No. 1 CRUSHED STONE.
FINISHED GRADE
6" MINIMUM NO.2 CRUSHED STONE. (COMPACTED LEVEL BASE)
TYPICAL CATCH BASIN DETAIL
STORM SEWER BEDDING DETAIL
NOT TO SCALE
NOT TO SCALE
REVISED BY COSTICH 05/24/2016
PLAN VIEW
24"x24"
FILL EXCAVATED AREA WITH #1 & #2 CRUSHED STONE. COMPACT IN 6" LAYERS. CONTRACTION JOINTS-D/4
N0.4 REBARS (TYP.)
25"
FLOW
2"
BRUSHED FINISH
20'
24"x27" NOMINAL
MANHOLE FRAME AND COVER TO BE NEENAH R-1726, SYRACUSE CASTING OR APPROVED EQUAL. MATERIAL TO MEET A.S.T.M. SPECIFICATION A-48, CLASS 30.
APPROPRIATE LETTERS "STORM" OR "WSD" TO BE CAST AS PART OF THE COVER. (2" HIGH)
2"
1"
- NOTE BEARING SURFACES TO BE MACHINED. ALL SURFACES TO BE BITUMINOUS COATED.
8"
TRENCH & CULVERT EXCAVATION
27-1/2"
18" DIAMETER FILTREXX R SOXX TM (ALSO AVAILABLE IN 8", 12" AND 24" DIAMETERS
PLAN VIEW 1'-0"
I.D. "A"
"A"
SEE NOTE 3
PIPE DIA.
DIM. "A"
UP TO 18"
12"
18" TO 36"
18"
OVER 36"
24"
2-3" LIFTS ASPHALT CONC. 37.5mm BASE COURSE
18" DIAMETER FILTREXX R SOXX TM (ALSO AVAILABLE IN 8", 12" AND 24" DIAMETERS)
2" ASPHALT CONC. 19mm BINDER COURSE 1 1/2" ASPHALT CONC. 9.5mm TOP COURSE FULL DEPTH SAWCUT EXISTING PAVED SHOULDER WIDTH PLUS 1' OR AS DIRECTED BY MCDOT ACCESS 24" ROAD
SECTION VIEW
COUNTY ROAD
FOR ANY PROJECT ON WHICH CONCRETE WILL BE POURED OR OTHERWISE FORMED ON SITE, A SUITABLE WASHOUT FACILITY MUST BE PROVIDED FOR THE CLEANING OF CHUTES, MIXERS, AND HOPPERS OF THE DELIVERY VEHICLES UNLESS SUCH A FACILITY WILL BE USED AT THE SOURCE OF THE CONCRETE.
ALL CONCRETE GUTTERS AND INLET APRONS TO BE 4000 P.S.I. TYPE I PORTLAND CEMENT (A.S.T.M. D-150)
CONSTRUCTION OF INLET IN PAVEMENT AREAS:
12"
8"
ANCHOR
12"
KEYWAY
12" WIDE CONCRETE APRON AREAS TO BE CONSTRUCTED COMPLETELY AROUND THE INLET (3000 P.S.I.) (AS SHOWN). FRAME AND GRATE TO BE APPROVED BY THE TOWN AND TO BE ABLE TO WITHSTAND THE LOAD OF VEHICLE TRAVEL. POSTIVE DRAINAGE (1/4"/FT SLOPE) TO BE OBTAINED IN THE CONCRETE APRON AREA SURROUNDING THE INLET.
EXISTING UNDERDRAIN TO REMAIN 6" TYPE 2 CRUSHED STONE SUBBASE COURSE
2. SELECT GRANULAR FILL OR SUITABLE NATIVE MATERIAL, AS APPROVED BY THE DEPARTMENT'S ENGINEER OR HIGHWAY MAINTENANCE MANAGER, SHALL BE COMPACTED IN A MAXIMUM OF 6" LIFTS AT 95% COMPACTION.
6"
4" DIA. PERFORATED POLYETHYLENE WEEP DRAIN PIPE. PIPE TO BE INSTALLED 20' ON UPSTREAM SIDE OF ALL GUTTER INLETS (C.B.'s). PIPE TO BE WRAPPED WITH AN APPROVED FILTER FABRIC AND ENDS TO BE CAPPED. PIPES ARE NOT REQ'D. IN ROCK OR WELL DRAINED SOIL, TO BE DETERMINED BY THE TOWN ENGINEER.
PAVEMENT SECTION AS SHOWN ON PLANS APPROVED BY THE LOCAL MUNICIPALITY
1. REPLACE PAVEMENT IN KIND WITH WHAT IS EXISTING, UNLESS CONDITIONS EXIST WHERE THAT ISN'T FEASIBLE, THEN INSTALL SECTION AS APPROVED BY THE DEPARTMENT'S ENGINEER OR HIGHWAY MAINTENANCE MANAGER. THE MINIMUM APPROVABLE SECTION SHALL BE 6" OF TYPE 2 SUBBASE (CRUSHER RUN STONE), 2" OF ASPHALT BINDER AND 1 1/2" OF ASPHALT TOP. SEE NOTE 6 FOR TRENCHES LESS THAN 24" WIDTH.
3. 6" OF STONE BEDDING, CONSISTING OF A BLENDING OF #1 AND 2 STONE, IS REQUIRED FOR SANITARY OR STORM SEWER INSTALLATIONS WITH CRUSHED STONE HAUNCHING TO A MINIMUM OF 1/2 OF THE PIPE DIAMETER ON THE SIDE OF THE PIPE. 4. IF CONCRETE BASE IS EXISTING, IT MUST BE REPLACED WITH A MINIMUM OF 6" OF ASPHALT BASE. 5. IF PAVEMENT MARKINGS OR SIGNAL LOOPS ARE DESTROYED, THEY MUST BE REPLACED. 6. WHEN TRENCH WIDTH IS LESS THAN 24", FLOWABLE FILL MUST BE PLACED ABOVE THE 6" OF #1 AND 2 STONE BEDDING TO BINDER GRADE. A 2" LIFT OF BINDER AND A 1 1/2" LIFT OF TOP ASPHALT MUST BE THEN INSTALLED TO FINISH GRADE.
NOTES:
SECTION A-A
1. ALL ACCESS ROADS SHALL MEET THE COUNTY HIGHWAY AT A RIGHT ANGLE (90°), UNLESS OTHERWISE AUTHORIZED BY THE COUNTY SUPERINTENDENT OF HIGHWAYS OR DESIGNEE. 2. RIGHT-OF-WAY WIDTH VARIES. 3. RADIUS MAY VARY DEPENDING ON PROPOSED VEHICLE USAGE FOR ACCESS ROAD. REVISED 9/17/14
11/18/14 REVISED
SEWER MANHOLE FRAME - COVER
GUTTER AND CATCH BASIN DETAIL
STANDARD YARD INLET DETAIL
TRENCH AND PAVEMENT RESTORATION FOR ROAD CUT
ACCESS ROAD CONNECTION WITHOUT CURB OR GUTTER TO A COUNTY HIGHWAY WITH SHOULDER
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
1"
6"
1"
REVISED BY COSTICH 05/24/2016
MAXIMUM DEPTH OF CONTAMINATED WATER IS 50% OF CONCRETE WASHOUT HEIGHT.
2"x2"x36" WOODEN STAKES PLACED 5' O.C.
SECTION VIEW
6" 6"
R=30' SEE NOTE 3 P.C.
4"
CAPPED END
EXPANSION JOINT (TYP.) 6"
1-1/2"
SUBBASE TYPE 2 (2 - 6" LIFTS)
6" NO. 1 AND 2 CRUSHED STONE BEDDING
* NOTE: 1. PAINT INSIDE WALLS OF INLET WITH (1) COAT & THE BOTTOM OF INLET WITH (2) COATS OF KOPPERS BITUMASTIC 300-M, BRIGGS FABERTITE (C) OR APP. EQUAL. 2. THE TOWN OF WEBSTER REQUIRES A 2-3" DEEP AREA AT INLET BOTTOM (BELOW THE OUTLET ELEV.) FOR COLLECTION OF SILT, DEBRIS, ETC. 3. ALL YARD INLETS SHALL BE 24"x24"
35"
1/4"
SEE NOTE #2*
3500 P.S.I. CONCRETE
26-1/4"
24-1/2"
6"
2" MIN.
DISCHARGE STORM PIPE
TROWEL FINISH
3/4"
4"
SEE NOTE #1*
EXISTING CONCRETE BASE (SEE NOTE 4)
SELECT GRANULAR FILL OR SUITABLE NATIVE MATERIAL
4" PLASTIC PIPE ON ALL SIDES OTHER THAN THE SIDE OF DISCHARGE.
EXISTING ASPHALT BASE (SEE NOTE 1) TACK COAT
3"
22-3/4"
"STORM" OR "WSD"
ANCHORS SET IN MORTAR
P.T.
6"
7-1/2"
1-1/2"
GALVANIZED FRAME AND GRATE, (BORDEN NO.1 OR APPROVED EQUAL)
8"
PRE-CAST CONCRETE STRUCTURE (4000 P.S.I.)
6", TYP.
PROPOSED ACCESS ROAD
1. UNDER NO CIRCUMSTANCES MAY WASH WATER FROM THESE VEHICLES BE ALLOWED TO ENTER ANY SURFACE WATERS. 2. CONCRETE WASHOUT SHALL BE UNDERLAYED WITH 10 MIL. THICK PLASTIC BUFFER. 3. MAKE SURE THAT PROPER SIGNAGE IS PROVIDED TO DRIVERS SO THAT THEY ARE AWARE OF THE PRESENCE OF WASHOUT FACILITIES. 4. WASHOUT FACILITIES SHOULD NOT BE PLACED WITHIN 50 FEET OF STORM DRAINS, OPEN DITCHES OR SURFACE WATERS. 5. INSTALL ON FLAT GRADE NOT TO EXCEED 2%. 6. CONCRETE WASHOUT MAY BE STACKED IN A PYRAMIDAL CONFIGURATION FOR ADDED HEIGHT AND STABILITY. 7. CONCRETE WASHOUT MAY BE DIRECT SEEDED AT THE TIME OF INSTALLATION. 8. THEY SHOULD BE IN A CONVENIENT LOCATION FOR THE TRUCKS, PREFERABLY NEAR THE PLACE WHERE THE CONCRETE IS BEING POURED. 9. CONCRETE WASHOUT NOT TO BE LESS THAN 6' IN DIAMETER.
APPROVALS
BY:
TOWN ENGINEER
BY:
PLANNING BOARD CHAIRPERSON
BY:
TOWN HIGHWAY SUPERINTENDENT
CONCRETE WASHOUT DETAIL NOT TO SCALE BY:
WEBSTER SEWER DISTRICT
BY:
TOWN ASSESSOR
BY:
FIRE MARSHAL
PROJECT MANAGER
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
BY
CHKD.
APVLS.
H
REVISION
ED
DATE
NS
NO.
C
PR
0 9 6 1 84
OF E
AL S S I ON
Civil Engineering
DRAWN BY
L I CE
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
TE EL O R I T Y HA
TITLE OF PROJECT
W.T.A.
O F N EW
RK O IE
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
ER
UNDISTURBED GROUND OR ROCK
NOTE:
20' MIN. & VARIES
A
W.T.A.
TITLE OF DRAWING
J.S.F. TOPO/BASE
Landscape Architecture
G.L.R.
DETAILS PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
AS NOTED
BELLA TERRA SUBDIVISION SECTION 2
Land Surveying
BOUNDARY
I NE
FILTER FABRIC -WRAPPED (MIRAF) (40S OR APP. EQUAL)
SAW CUT EXISTING PAVEMENT EACH SIDE, TACK COAT ALL CUTS, AND CAP SEAM WITH BITUMINOUS SEALER
A
NG
O.D./2
6" MIN.
TOWN INSPECTOR MAY REQUIRE SELECT OR IMPORTED BACKFILL IF FIELD CONDITIONS NECESSITATE.
RECTICULINE GRATE TO BE A GALVANIZED #9 OR EQUAL TO N.Y.S.D.O.T. DWG. NUMBER 655-3.
P.T.
E
N.Y.S. SPEC 706-04 STEEL REINFORCED PRE-CAST CONCRETE OR APPROVED EQUAL 3000 P.S.I. CONCRETE
FLOW
PUMP CONTAMINATED WATER INTO CONCRETE WASHOUT
A
3"
2" ASPHALT CONCRETE, 19mm BINDER COURSE
4" PLASTIC PIPE (TYP.)
R=30' SEE NOTE 3
ASPHALT CONCRETE, 37.5mm BASE COURSE (SEE NOTE 1) MIN. 6", 2 - 3" LIFTS
C
6" MIN.
A
VARIES (2'-6" MIN.)
PORTLAND CEMENT MORTAR
26" (VARIES)
12" DIA. PERFORATED 16 GAUGE C.M.P. AT 1% MIN. SLOPE - ASPHALTIC COATED (OR 12" DIA. PERF. CORRUGATED POLYETHYLENE) TO GUTTER INLET
O.D.
ASPHALT CONCRETE, 9.5mm TOP COURSE MIN. THICKNESS 1 1/2" (SEE NOTE 1)
ST
24" WIDE
A
COMPACTED SELECT FILL TO ROAD SUBBASE IN PAVEMENT AREAS. SELECT FILL SHALL BE SAND, GRAVEL AND SIMILAR MATERIAL WHICH SHALL BE FREE FROM CLAY, LOAM, ORGANIC MATERIAL, DEBRIS, OR FROZEN MATERIAL, AND SHALL CONTAIN NO STONES PEBBLES OR LUMPS OVER 2" IN GREATEST DIMENSION.
MI
NATIVE BACKFILL COMPACTED TO 95% STANDARD PROCTOR ASTM-D698 ON ALL SIDES AS SHOWN.
48" MINIMUM
4" DIA. PERF. PLASTIC PIPE, 20' ON UPSTREAM SIDE OF CATCH BASIN. (GUTTER WEEP)
NO.4 REINFORCING BAR (BOTH SIDES)
3'-0"
KEYWAY (TYP.)
2 COATS ASPHALTIC WATERPROOFING (KOPPER BITUMASTIC 300M. BRIGGS FABERTITE (C) OR APPROVED EQUAL. (INSIDE AND OUTSIDE OF WALLS)
1-1 /
P.C.
2" MIN.
COMPACTED COMMON FILL
2"x2"x36" WOODEN STAKES PLACED 5' O.C.
COUNTY HIGHWAY
6" MIN. TOPSOIL
ROAD PAVEMENT (SEE DETAIL ENTITLED "TYPICAL ROAD CROSS SECTION DETAIL"
17' MIN. OR MATCH EXIST. EDGE OF SHOULDER
CL
2.5"
3'-0"
E . SLOP
10' MIN. (TYP.)
1% MIN
SAW CUT FULL DEPTH AND TACK COAT
1.5" FINISHED CENTERLINE ROAD GRADE
80' MIN. AND VARIES
GALVANIZED FRAME AND GRATE (BORDEN NO.1 OR APP. EQUAL.)
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11
CA500 SHEET 8 OF 9
BEND OR FITTING
HYDRANT MARKER NOTES:
1" TOP COURSE (1.5" FOR MAJOR ROADS)
NOTE:
HYDRANT MARKER 3'
NO. 5 REBAR (5/8")
A (FT)
1.5
2.0
1.5
2.0
2.5
1.5
1.5
2.5
1.0
H (FT)
VOL (CY)
L (FT)
W (FT)
H (FT)
VOL (CY)
L (FT)
W (FT)
H (FT)
VOL (CY)
L (FT)
W (FT)
H (FT)
VOL (CY)
3.0
3.6
3.6
1.5
3.0
3.6
3.6
1.5
4.5
5.4
5.4
4.9
6.0
7.2
7.2
11.5
8"
SOIL BEARING STRENGTH -
PSF
PSI TEST PRESSURE
VERTICAL DOWN THRUST BLOCKS 3"(TYP)
HORIZONTAL AND VERTICAL UP THRUST BLOCKS CL BOND BREAKER GRADE
1. THE CONTRACTOR/DEVELOPER IS SOLELY RESPONSIBLE FOR THE ABOVE ACTIONS; THE MONROE COUNTY WATER AUTHORITY WILL NOT MONITOR THIS WORK OR GUARANTEE IT's COMPLETION.
CONCRETE THRUST BLOCK UNDISTURBED SOIL
3 ft
NOT TO SCALE
NOT TO SCALE
BOND BREAKER
W
TYPICAL MONUMENT INSTALLATION
WEBSTER HYDRANT NOTES & HYDRANT MARKER DETAIL
TYPICAL ROAD CROSS-SECTION DETAIL
1.5
W (FT)
BEND PROFILE
H
CONCRETE THRUST BLOCK UNDISTURBED SOIL
BEND ELEVATION
VERTICAL UP THRUST BLOCKS NOT TO SCALE
NOT TO SCALE
3"
(T YP
GRADE
CL
CONCRETE THRUST BLOCK
CONCRETE THRUST BLOCK
)
A
V I CE IN
SE
R
GRADE
3. ALL VALVES SHALL BE OPEN LEFT EXCEPT: TOWN OF WEBSTER - VALVES 12" AND SMALLER SHALL OPEN RIGHT. TOWN OF HENRIETTA - SHALL OPEN RIGHT
DIP TRENCH
MONROE COUNTY
WATER AUTHORITY
SEPT 2016 DATE
ROCHESTER, NEW YORK
NOT TO SCALE
VALVE NOT TO SCALE
DME 3
MONROE COUNTY
WATER AUTHORITY
HYDRANT MARKER
SEPT 2016 DATE
ROCHESTER, NEW YORK
MONROE COUNTY
WATER AUTHORITY ROCHESTER, NEW YORK
NOT TO SCALE
DME 5
SEPT 2016 DATE DME 8
PLUG
CONCRETE THRUST BLOCK
TEE PLAN CORPORATION STOP
RIGHT-OF-WAY OR WATER MAIN EASEMENT LINE 5.5' BURY HYDRANT TO BE INSTALLED w/4-1/2" NOZZLE FACING THE ROADWAY
UNDISTURBED SOIL
TEE ELEVATION
WATER MAIN BEND
GRADE
WATER MAIN
CL A
BEND BOND BREAKER
H
2. VALVE SHALL NOT SUPPORT VALVE BOX.
EXCAVATION TO MEET OSHA REQUIREMENTS.
UNDISTURBED SOIL
UNDISTURBED SOIL BOND BREAKER
1. VALVE BOX SHALL BE CENTERED ON VALVE AND SET ON COMPACTED BACKFILL.
TRENCH LIMITS
CONCRETE THRUST BLOCK
ALL LETTERING SHALL BE 2" MINIMUM AND PAINTED BLACK BY USE OF A STENCIL. HYDRANT MARKER TO BE INSTALLED AND MAINTAINED ON STEAMER NOZZLE OF EACH HYDRANT UNTIL HYDRANT IS PLACED IN SERVICE.
SOLID CONCRETE BLOCK (MIN: 4"x8"x16" UP TO 12" VALVE 8"x8"x16" LARGER THAN 12" VALVE)
6"MIN IN ROCK
L
1" COPPER OR PLASTIC (MIN)
VALVE
6" 6"MIN IN ROCK
12" DIAMETER x 1/8" THICK (SOLID) RED OR ORANGE PLASTIC DISK TO READ: "NOT IN SERVICE"
5'-0" MIN
SHEET OF POLYETHYLENE ENCASEMENT OVER TYPE 7 SELECT FILL TYPE 7 SELECT FILL FOR WIDTH OF TRENCH AROUND VALVE BOX
PIPE ZONE
6"
DEPTH OF COVER AS SPECIFIED 5'MIN IN LAWN 6'MIN IN PAVEMENT
BASE
N OT
TYPE 4 SELECT FILL (RUN OF BANK SAND) ENVELOPE (WHEN ROCK IS ENCOUNTERED)
12"
EXTENSION
BEND ELEVATION
3" (TYP)
MIN
VALVE BOX
UNDISTURBED SOIL
1" COPPER
W
1" CURB STOP
H
12"
W
CL
GRADE
MIN
SUITABLE NATIVE MATERIAL, COMPACT TO 85% MAX STANDARD PROCTOR DENSITY
90 DEGREE
W (FT)
DE WI
WATERMAIN
ALL ROADWAY WEEPS SHALL HAVE UNDERDRAIN THE FULL LENGTH OF THE ROAD
THE PLANNING BOARD MAY ESTABLISH CERTAIN ROADS AS "MAJOR COLLECTOR ROADS." THESE ROADS WILL REQUIRE THE ADDITIONAL DIMENSIONS/AMOUNTS AS INDICATED ABOVE.
1.5
H (FT)
45 DEGREE
L (FT)
* SIZE BLOCK BASED ON BRANCH DIAMETER. SOIL BEARING STRENGTH PSF PSI TEST PRESSURE
1. THE TOWN REQUIRES THE COLOR CODING OF THE 2.5" HYDRANT NOZZLES WHICH WILL INDICATE FIRE FLOWS: RED = 500 g.p.m. OR LESS ORANGE = 500 to 1000 g.p.m. GREEN = 1000 g.p.m. AND UP
HYDRANT MARKER LOCATION
APPROVED FILTER FABRIC, IF REQUIRED BY THE TOWN INSPECTOR WHEN UNSUITABLE MATERIAL IS ENCOUNTERED.
1.0
A (FT)
PIPE DIAMETER
PLASTIC CAP
2. CONTRACTOR SHALL CONTACT PROJECT ENGINEER FOR FLOW PRESSURE AND PAINT NOZZLES ACCORDINGLY.
2"
1.5
W (FT)
90 DEGREE
2221 DEGREE
3" (TYP)
3" BINDER COURSE (3.5" FOR MAJOR ROADS)
4" DIA. PERFORATED POLYETHYLENE WEEP DRAIN PIPE. PIPE TO BE WRAPPED WITH AN APPROVED FILTER FABRIC. PIPES ARE NOT REQ'D. IN ROCK OR WELL DRAINED SOIL, TO BE DETERMINED BY THE TOWN ENGINEER.
1.0
H (FT)
45 DEGREE
1141 DEGREE
H
3" (#3) CRUSHER RUN STONE-SECOND COURSE
1.0
BEND TEE*, CAP OR PLUG H W A (FT) (FT) (FT)
A
#1 AND #2 CLEAN STONE (IN GUTTER WEEP AREA, THE ENTIRE LENGTH OF THE ROADWAY)
EXISTING GRADE
HYDRANT NOZZLE COLOR NOTES:
GRADE
9" (#3) CRUSHER RUN STONE-FIRST COURSE PLACED IN TWO LIFTS. 2 FEET
SUB-GRADE COURSE (IF REQ'D.)
8"
4. ALL FIRE HYDRANTS PROPOSED IN THIS PROJECT SHALL HAVE A HYDRANT MARKER AS SHOWN IN THIS DETAIL.
4-1/2" 17-1/2"
8"
3. MINIMUM HEIGHT ABOVE GRADE IS 6 FT.
PAINTED GREEN
6"
2. POST TO BE PAINTED GREEN WITH TOP 3 FT. PAINTED YELLOW.
1-1/2"
EXCAVATE TO ACCEPTABLE SUB-BASE (12" MIN.)
PIPE 11-1/4 DEGREE 22-1/2 DEGREE DIAMETER H W A H W A (FT) (FT) (FT) (FT) (FT) (FT)
36" MIN. 42" MAX.
2-1/2"
PAVEMENT CENTERLINE
10'-0"
6 FEET
1'-6"
1'-0"
PAINTED YELLOW
6"x30" CONC. GUTTER
13'-0"
1. DELINEATOR POST, FLANGED CHANNEL (2"x7/8"x1/8") (8' LENGTH, STEEL)
DISINFECTION/ BLOW-OFF/ SAMPLING TAP (TEMPORARY)
IN THE PRESENCE OF A WATER AUTHORITY REPRESENTATIVE REMOVE ALL CORPORATIONS ASSOCIATED WITH TEMPORARY DISINFECTION/SAMPLE TAPS AND REPLACE WITH THREADED BRASS PLUGS.
MONROE COUNTY
WATER AUTHORITY ROCHESTER, NEW YORK
NOT TO SCALE
REBAR (TYP) CONCRETE THRUST BLOCK BOND BREAKER
W
UNDISTURBED SOIL
BEND PLAN
CONCRETE THRUST BLOCK
1. THRUST BLOCKS SHALL BE CENTERED HORIZONTALLY ON BENDS. 2. VOLUMES SHOWN IN CHART ARE MINIMUMS.
UNDISTURBED SOIL
BEND PLAN
SEPT 2016 DATE
HORIZONTAL THRUST BLOCKS
DME 14
NOT TO SCALE
BEND ELEVATION MONROE COUNTY
WATER AUTHORITY ROCHESTER, NEW YORK
VERTICAL DOWN THRUST BLOCKS
SEPT 2016 DATE
MONROE COUNTY
WATER AUTHORITY ROCHESTER, NEW YORK
NOT TO SCALE
DME 6
SEPT 2016 DATE DME 7
DRILL 3/16" HOLE 4-1/2" FROM TOP OF VALVE BOX AND INSERT TRACING WIRE AND KNOT
GRADE GRADE SERVICE LINE 12"MIN
WATER MAIN
SHEET OF POLYETHYLENE ENCASEMENT OVER TYPE 7 SELECT FILL
TYPE 7 SELECT FILL FOR WIDTH OF HYDRANT TRENCH
WATER MAIN CURB BOX AND ROD
MJ ANCHOR TEE, 6" OUTLET
VALVE BOX w/TOP
SOLID CONCRETE BLOCK (MIN:4"x8"x16")
GRADE
SOLID CONCRETE BLOCK (MIN:8"x8"x16") 6"x18" (MIN) ANCHOR PIPE ONE CONTINUOUS LENGTH FROM VALVE TO HYDRANT
2" COPPER / BRASS PIPE
PERPENDICULAR HYDRANT ASSEMBLY NOT TO SCALE
MONROE COUNTY
WATER AUTHORITY ROCHESTER, NEW YORK
WATER MAIN
COATED TRACING WIRE
1. COPPER SERVICE TO BE USED UNLESS OTHERWISE APPROVED BY THE ENGINEER.
6" MJ GATE VALVE CAP
CORPORATION STOP (INSTALL WITH OPERATING KEY POSITIONED ON SIDE)
2°
DI MJ TAPPED TEE (2" TAP), ROTATED DOWN 45° NOTE: SAME SIZE AS WATER MAIN
BARE TRACING WIRE TO BE WRAPPED AROUND AND TAPED TO CORPORATION STOP
22-1/
PLAN
SHEET OF POLYETHYLENE ENCASEMENT OVER TYPE 7 SELECT FILL
CONCRETE THRUST BLOCK LENGTH ALONG MAIN IS 2' (MIN)
5' MIN COVER
VALVE BOX
POLYETHYENE ENCASEMENT
5' MIN COVER
TYPE 7 SELECT FILL
SOLID CONCRETE BLOCK (MIN:4"x8"x16")
TRACING WIRE TO BE WRAPPED AROUND OUTSIDE OF CURB BOX CURB BOX w/ROD CURB STOP BARE TRACING WIRE TO BE ATTACHED AND TAPED TO COUPLING OR TO CONSUMER TRACING WIRE
BARE TRACING WIRE TO BE WRAPPED AROUND AND TAPED TO CURB BOX
2. TRACING WIRE TO BE USED WITH POLYETHYLENE SERVICE ONLY. SEPT 2016 DATE DME 9
SERVICE INSTALLATION NOT TO SCALE
MONROE COUNTY
WATER AUTHORITY ROCHESTER, NEW YORK
SEPT 2016 DATE DME 17
2" x 90° BRASS BEND 2" BRASS PIPE
2" BRASS NIPPLE
2" x 45° BRASS BEND
DME 16
APPROVALS
BY:
TOWN ENGINEER
BY:
PLANNING BOARD CHAIRPERSON
BY:
TOWN HIGHWAY SUPERINTENDENT
BY:
WEBSTER SEWER DISTRICT
BY:
TOWN ASSESSOR
BY:
FIRE MARSHAL
PROJECT MANAGER
COPYRIGHT © 2023 COSTICH ENGINEERING, D.P.C.
BY
CHKD.
APVLS.
H
REVISION
W.T.A.
0 9 6 1 84
OF E
AL S S I ON
TITLE OF DRAWING
J.S.F. TOPO/BASE
Landscape Architecture
G.L.R.
DETAILS PORTION OF TAX PARCEL 065.020-01-040.221 TOWN LOT 6, 7, 12, & 14 , TOWNSHIP 14 , RANGE 4, SECTION 11, PHELPS AND GORHAM PURCHASE, TOWN OF WEBSTER, COUNTY OF MONROE, STATE OF NEW YORK
LOCATION OF PROJECT
DATE
12/13/2023 SCALE
AS NOTED
BELLA TERRA SUBDIVISION SECTION 2
Land Surveying
BOUNDARY
I NE PR
Civil Engineering
DRAWN BY
ER ED
DATE
NS
NO.
C
L I CE
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, LAND SURVEYOR, ARCHITECT OR LANDSCAPE ARCHITECT, TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY . ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS/HER SEAL AND THE NOTATION "ALTERED BY", FOLLOWED BY HIS/HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATION, TO THE DOCUMENT.
TE EL O R I T Y HA
TITLE OF PROJECT
W.T.A.
O F N EW
RK O IE
EXISTING UTILITIES (LOCATION, SIZES AND INVERTS) SHOWN ON THE PLANS ARE APPROXIMATE AND ARE NOT CERTIFIED AS TO THE ACCURACY OF THEIR LOCATION OR COMPLETENESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATIONS AND DEPTHS OF ALL UTILITIES AND STRUCTURES IN THE PATH OF, OR CLOSELY PARALLEL TO, OR UNDER, THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DELAYS OR DAMAGES OCCURRING AS A RESULT OF INCORRECTLY LOCATED UTILITIES. IT IS THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITY OWNERS IN AMPLE TIME FOR THEM TO LOCATE AND MARK THEIR FACILITIES. THE CONTRACTOR SHALL ALSO NOTIFY UNDERGROUND UTILITY LOCATION SERVICE AT LEAST 48 HOURS IN ADVANCE OF COMMENCING ANY WORK.
NG
ROCHESTER, NEW YORK
E
WATER AUTHORITY
SEPT 2016 DATE
A
NOT TO SCALE
MONROE COUNTY
C
TEE w/2" BLOW-OFF
CONCRETE BLOCK (MIN:4" x 8" x 16")
ST
ELEVATION
MI
2" BRASS NIPPLE
2" CURB STOP w/DRAIN
Costich Engineering
217 Lake Avenue Rochester, NY 14608 (585) 458-3020
CLIENT
800 PHILLIPS ROAD, L.L.C. 55 ALLIED WAY HILTON, NY. 14468 PHONE NO.: 585-392-3222
DWG. #
4500.11