1020 Lehigh Station Road Henrietta, New York 14467 585-334-1122 www.Lefrois.com New wall Existing chairs/tables relocated here
Employee break room 010 Sales 005
Women 007
Men 008
Business Center 009
NEW refrigerator for employees Existing millwork with sink relocated here
New door and walls
New door and wall
Beverage Sink not Counter required
Parts Manager Office 012
Utility 013
Parts Storage 014 Retail space 011
use ipads for sales
Customer lounge 006 1 A7 Showroom 001
F-32 Marketing media center mounted above centered on main entry
Frost windows looking into parts storage
Infill opening F-25 apparel display. RCC to approve final location
New counter ledge (wood grain laminate). Scope by LeFrois
DRAWING ALTERATION
Existing Electrical Panel
Sales Mgr 004
Drop safe, floor mounted within one base cabinet, concealed by door
The following is an excerpt from the New York State Education Law Article 147 Section 7207 Part 69.5b and applies to this drawing.
Sales 003
"it is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter an item in any way. If an item bearing the seal of an architect is altered, the altering architect shall affix to his item the seal and the notation "altered by" followed by his signature and the date of such alteration, and a specific description of the aleration."
Service 015
EV charger relocated here Add one service bay
Service manager 002 REVISIONS PROGRESS PLOT
4/8/24
ISSUED FOR PERMIT
20'-9"
ISSUED FOR CONST.
9'-0"
Service Advisors 017
3'-0"
5'-10"
13'-2"
2'-0"
ISSUED FOR FINAL BIDDING
29'-6"
3'-0"
New storefront glass and door relocated
NO.
DATE
DESCRIPTION
1
11/17/17
Progress Set NREDI Renovation
4/8/24
1 A1
25'-0"
23'-9"
Service Reception 016 16'-0"
ACT at 12'-0" aff
2 A8
SMC Window into service manager office (4'x3')
Door into showroom
50'-0"
1 A8
PROJECT
3 A8
VISION NISSAN Webster F-13A
Proposed Floor Plan 1/8" = 1'-0"
All furniture/lockers provided by owner
1
F-13A
Service Advisors Elevation 1/4" = 1'-0"
All furniture/lockers provided by owner
LOCATION
785 Ridge Rd Webster Monroe County New York
DRAWING TITLE
Proposed Floor Plan SHEET NO.
SCALE:
As noted
DRAWN BY:
A-1
BRM
DATE:
Dec. 2017
DRAWING:
ACM-3
MTL. PANELS TO MATCH EP-5
TOP OF PARAPET 16'-0"
1020 Lehigh Station Road Henrietta, New York 14467 585-334-1122 www.Lefrois.com
ACM-1
MTL. PANELS PAINTED TO MATCH EP-5
TOP OF PARAPET 14'-6"
EAVE HT. 16'-0"
FIN FLOOR 0'-0"
CMU EP-5
CMU PAINTED TO MATCH EP-5
ADDITION
BOTTOM OF FTG -4'-0" MIN NOTE: New configuration of storefront glass and doors.
STOREFRONT GLAZING; CLEAR GLAZING W/ CLEAR ANODIZED ALUMINUM MULLIONS, TYP.
MATERIAL SCHEDULE
Proposed West Elevation
AREA
1/8" = 1'-0"
EXTERIOR ACM-1 ALUMINUM COMPOSITE MATERIAL - SILVER
CODE ITEM
ACM-3 ALUMINUM COMPOSITE MATERIAL - DARK GRAY EP-5
All secondary elevations to be painted EP-5. We do not recommend painting factory finished metal. If the dealer team chooses to, the dealer team should consult a painting professional for specific guidance, but even so, it could be a maintenance issue in the future.
PRODUCT
COLOR
ALPOLIC
BSX SILVER METALLIC
ALPOLIC 732L878 (FEVE)
NSG NISSAN GRAY
PAINT - DARK GREY
TO MATCH SHERWIN WILLIAMS 7076 CYBERSPACE OR RAL 7024 7024 GRAPHITE GRAY
B-1
BOLLARD
PRE FINISHED BOLLARD
ACM-3
MTL. PANELS PAINTED TO MATCH EP-5
LIGHT GREY PAINT OR VINYL SLIP ON
STAINLESS STEEL
ACM-1 DRAWING ALTERATION
EAVE HT. 16'-0"
The following is an excerpt from the New York State Education Law Article 147 Section 7207 Part 69.5b and applies to this drawing. "it is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter an item in any way. If an item bearing the seal of an architect is altered, the altering architect shall affix to his item the seal and the notation "altered by" followed by his signature and the date of such alteration, and a specific description of the aleration."
FIN FLOOR 0'-0"
CMU PAINTED TO MATCH EP-5
BOTTOM OF FTG -4'-0" MIN
STOREFRONT GLAZING; CLEAR GLAZING W/ CLEAR ANODIZED ALUMINUM MULLIONS, TYP.
Proposed East Elevation
BUILDING ENVELOPE THERMAL COMPLIANCE
1/8" = 1'-0"
Where possible, do not mount anything to the silver acm band (ACM-1). Please try and mount all obstructions on a different plane that wont interfere with the signage. All obstructions: cameras, lights, speakers, etc must match adjacent surface in color.
Dealer to verify height requirements of service operations before installing EMBs. They are mounted within the OHD recess, thereby reducing clearance heights.
COMPONENT
DESCRIPTION
Roof 1:
ASSEMBLY 'U' VALUE
Standing seam metal roof with R30 insulation (warehouse)
---
0.043
Floor:
Concrete slab on grade; R10 rigid vertical perimeter insulation
10.0
Walls:
Wall 1:
8" 'Omni block' cmu with integral insulation inserts
---
Wall 2:
'E-Shadowall' metal wall panel with R-25 batt insulation
---
Wall 3:
ACM wall panel with R-25 batt insulation
---
?
Door A:
Swinging, insulated metal
---
0.55
Door B:
Non swinging, insulated metal; (sizes vary)
---
0.190
Fenestration:
ACM HEIGHT TO BE 5'-0" TO ACCOMMODATE SMALL SIGN FAMILY
ACM-1
INSTALL T43 TABLET WITH SMALL LETTERSETS SIGN PROVIDED BY AGI
PARAPET HT. 19'-5 1/2"
ACM-3
PROGRESS PLOT
4/8/24
ISSUED FOR FINAL BIDDING ISSUED FOR PERMIT
R VALUE
Nissan wordmark to be 1N from edge, where N is the height of N in the Nissan wordmark.
REVISIONS
ISSUED FOR CONST.
NO.
0.048
DATE
DESCRIPTION
NREDI Renovation
4/8/24
0.045
See 'Comcheck' documentation for complete building envelope energy code compliance
ADDITION
INSTALL SMALL SIGN FAMILY BY AGI RIDGE HT.
ADDITION
EAVE HT. 16'-0"
TOP OF PARAPET 16'-0"
EAVE HT. 16'-0" EAVE HT. 14'-6"
PARAPET BEYOND MTL WALL PANELS EP-5 12
12
WALL PANELS PAINTED TO MATCH EP-5
PROJECT
.5
.25
VISION NISSAN LOCATION
TOP OF CMU 4'-0" FIN FLOOR 0'-0"
FIN FLOOR 0'-0" BOTTOM OF FTG -4'-0" MIN
12x12 GARAGE DOOR W/ VISION PANELS
CMU PAINTED TO MATCH EP-5
Proposed North Elevation 1/8" = 1'-0"
STOREFRONT GLAZING; CLEAR GLAZING W/ CLEAR ANODIZED ALUMINUM MULLIONS, TYP.
NEW BOLLARD B-1 BOTTOM OF FTG -4'-0" MIN
785 Ridge Rd Webster Monroe County New York 12x12 GARAGE DOOR W/ VISION PANELS
NEW BOLLARD B-1
CMU EP-5
12x12 GARAGE DOOR PAINTED TO MATCH EP-5
BOLLARD TO BE PAINTED TO MATCH EP-5
CMU PAINTED TO MATCH EP-5
DOOR TO BE PAINTED TO MATCH EP-5
DRAWING TITLE
Proposed Elevations
Proposed South Elevation 1/8" = 1'-0"
SHEET NO.
SCALE:
As noted
DRAWN BY:
A-3b
ADR
DATE:
July 2023
DRAWING: