eee et

Leal i . 12" 7 ‘ - = ae _

422 ee + SHOWER NOTES. Sa Bh wie Bi-d" yal sad! |b Sie! “BHOWER |S Te BE TILED Site. CONSTRUCTED | 33° ays" _BHOWER BASE |S To BE Mat Soup ,

. | | | ae te “ERRFACE MATERIAL w/ SINGLE DAAIN, 30.30

7 | “ | | 4 > THRESHOLD # 3 SIDES w/ WALL FUNGE. “SHOWER SEAT \s To BE eerky “SURFACE ONE PIECE PITCHED TO DRAIN | | CWAWS “To BE TED. Bw SCHULTE TIUE BASE £ =e 3 3 = oe : a rn eee 5 i B an, READ, WALL

a

—{_.

randallfpeacock@gmail.com

ARCHITECT

545 Spring Meadow Lane ; - Webster, New York 14580

L

AT

585-746-5984

| s| ‘s O q | (Daal 62"

eT ERISTNG SALVAGED

¥ | Oo < _ § Q | <<

7

ene, oN SAND ¢ ON i See MALUED PVC" eae SESTOAWNT

- —d= —

2'-<' = 2 Oud

= —} : aH SSE dees Fine a 3 = 54 SL ees | Al —2i)2" eee em MTD TO_4ve4 a) na BS" Se : PSST w/ SFPSET BRACKETS A= 07°20 a0" — SF | Ae et EXOTNG GUARDRAIL POST Re Bid. gi ae 7 WINes ROOM a _— , . — ~ : / ri 2@) am) LA Ie SATH S# " = Ww AVT Fl SRING 53 ‘ : | Aan : ——— y- TH | of STING DEC pe \ ~XO : SU RLOORING oan s pots oe at ; , an an _ nl? _ ony ( = — 3 ’ ~ f 4 > a | AND POSTS, SALVAGE BAILING = #5 seate = =o jf te i 1s FoR REUSE | | 7 3 aa an | ®) fl | = i | = ie — | ——_——. REMOVE FRISTING STEPS AND , 2p Ost 9 a e pro : cs — ~ RAILINGS GENERAL NOTES AND_ SPECIFICATIONS headin | at 3 nt Lb hood: at WEAVE NEW DECENG | ; 01 GENERAL NOTES - Ee Thee _ 9 ft " | , | 1) This set of construction documents has been prepared for a “Design Build” project. This means that . _ ad {LI . \ . tk - HI T = BO ce et ee ge there are specific interior and exterior materials and elements that have not been identified in the : | ' " ‘RANCHE ne. ; T —f — | p drawings. The Contractor shall confer with the owner for selection of these materials. - Gas Ly lL 240 J 30" , att: _ [ ; Busine: Se CES PIRES - | ’ 2) The Contractor(s) shall be responsible for safety precautions and employee training and : . ; - et Dow FT SS i ee \ — —| . : _ o t safety programs necessary in conjunction with the work of this project. The Contractor a = og NI. Aan Sain is eal : , sntomeile’ tt : shall indemnify the Owner and the Architect through adequate insurance coverage . : —— : : 7 against any claims arising from construction-related injuries or injuries resulting from a , fou as fail t intai f diti the job site. Th tractor shall ide th with Certifeates of Insurance indicating that the Contractor has. in force statutory | Lp . RELOCATE Busts FURNACE € VENT Workmen's Compensation Insurance and adequate Builders Liability Insurance, 2 SET MU. BEL OW ; | AND. COMBUSTIO APS PLEES (minimum of 1 million dollars per occurrence). The contractor shall maintain adequate : ™ a A collision and liability insurance on all of his owned or leased vehicles used in conjunction AN SIMPSON. ‘sapuded RELOCATE Ale. ELECTRIC DISCONNECT with this project. The contractor shall notify the owner immediately if any of these policies Hoe POLT INTO cM EKI hould | be terminated during th f th tructi ject. The G | ~ —$-- f sree Shel oe Tooponebla feverhing tel subconvator cary the miu “Cayapcl caps Te ATC BEAM 7 RELOCATE A/C CONDENSED & PAD insurance requirements identified above. : wes : REMOVE EXISTING Hose \B\e> 3) The owner shalt obtain hazard insurance on the structure and property to protect the - ad pos at ere Post 7, foots . owner and contractor from damage to the structure by natural causes or vandalism GuaRD RAIL WME fi: / _RPEMOVE EXISTING PUR NACE VENT during the process of construction. oe GAWAGE Ree DECE RAILING |e. fm AND COMBUSTION Ale PIPES oe oo | | pore leLe RONDEAIL ON OFF= Bap | 4) This project has been designed in conformance with the requirements of the 2020 New paneer , no York State Residential Code (NYSRC) and the 2020 New York State Energy . ’ RELA CATE. Ale CONDENSER UNIT Conservation Construction Code. The Contractor(s) shall be responsible for : ; NO, PAD ( (ALSO. REMOVE & FuUEC understanding and complying with these codes and with all additional local, state, and . I cowoaie ta a 7eEp9s owe i ' mS CONNECT) federal laws, codes, standards, and regulations applicable to this project and its ; ty ; . - - construction. Ee ° @ 24 ac, WG al E

5) The Contractor shall be responsible for obtaining a building permit and shall include in his pricing all necessary permits and inspection fees for the Town of Webster, New York, in which the project is located.

REMoVE

ExsTINS, WINDOW, INFILL PART EE AMS IN KINDS, INSTALL NeW .

6) The Contractor(s) shall be responsible for supplying all materials, labor, assemblies,

finishes, etc., to provide the owner with a complete job, the quality of which matches or . =) a ap : HGah AND HEADERS. boOR Toa INCLUDE a exceeds the highest reasonable standard of quality found in the local industry. . A OE AUETNG SIDING €¢ ALVAGE - : — . . - ; LOCKING | LATCASET. (INCLUDE WIDE, “T~HOLD 7) The Contractor(s) shall be responsible for construction means and methods, including i RE-USE. INSTAL Ded. Fuse |< RINVe) i ., , . * ‘ : - . 4 \ . ‘ a a - on (but not limited to) temporary shoring of existing structures to be preserved and/or ENED Rast. PWD SHEATHINY PI . “aE ake pe — — SHADED. RBEA INIDICATES NEW ‘SE0F cea kay ae reconstructed, temporary shoring of new construction where required, temporary 2 = Va -¢ 5 “ba - PITCH. CNERBUNT. ON EXISTING i 12 SARAGE connecting structures, etc. The shoring shall be maintained until such time as the work , : fit sews EE i te nen nmeaaiae Bi). eD, ROOF. USE NAD %. 2 BEARING PLATE AT Pro i bl db d in its final fi tion. Shori d bracing desi hall 6 , . \ Cola ' , a proded bythe contador, “omoaten, Sheng and tretng Gesgn shel te Be rath ryeb a T8- f aye — Reese 2 AT VALLEY ~ REMOVE EXISTING . 8) Material, products, fixt d t shall be installed in strict d ith th | re | “Boea & Vac © wa) caves Nees Ware — aterial, products, fixtures and equipment shall be installed in strict accordance wi e oe ee 7 K€ VALLES’ we Manufacturer’s written instructions or shop drawings. Applicable requirements of the rome iy a, nS BACE | pm be A building code shall be adhered to. ; os a : are “TYPE: Ke cr. sal on (SHIELD ' LNDERLAYM NT" ' feoet 9) Thecontractor shall be responsible for familiarizing himself with the Contract Documents, _— a ea SlnFACE. MTD. aed G. UGHT IN EXIST, Wj : Ss field conditions, and dimensions. Prior to ordering materials or proceeding with WIDE. CONC PAYER » WALK AY seT-5 4 : ee WA. swiTcH = =. PITRE TO =. tt DATE construction the contractor shall confirm that the work may be accomplished as shown. ; . . ; ct COAPAC CON NSHED - t The contractor shall further be responsible for advising the Architect of any ; ee me ew em IN respite: a th wo discrepancies and/or conflicts between the existing conditions and the proposed work Ltd STONE. USE P . (C RESTRAIr Minh G Bi aE im ~ AM } prior to proceeding with the work in question. Should there be any questions related to the : ee ee SOEs OF EMSTING ¢ Gonaae. Gage * — —— Contract Documents, existing conditions, and/or the design intent, the contractor shall be 4 “) oP5O + MU wh TPES. CNP, BD. FoR. MIN, BO OMI DRAWN Bf | responsible for obtaining a clarification from the Architect prior to proceeding with the of REMOVE GRASS, FILL WW, T L ~ ; work in question. oo CLANT! INGS BY SHERS a 7 AL. PEACOCK -| 10) If, at any time, the Contractor(s) become aware of an error or inconsistency in ‘ DA bEEP ‘SoFRiT ABOVE KITCHEN CABINETS . Soe Tite oo these documents the Architect should be notified immediately, and a correction should “REMAVE. EST STING SSR ANO ) BRAM E & pe | , be solicited. | | BMNAGE Fat BEOSE WEILL OPENING IN - {FLOOR PLAN, SITE 11) Due to revisions made during the development of these plans they may not reflect the —— INP. ale BT SOLE ro SOLE PLATE Fi di ted. Wh ible the abb tion N.T.S. (Not to Scale) has b , 7 : — — ised to identify these conditions, DO NOT SCALE THE DRAWINGS! fa dimension 1s coho rors Age TT SHEET NUMBER | needed that cannot be deduced from the drawings contact the architect. a cee Ly ce Se a 12) Inthe event of a materials conflict, written specifications or notes are to take precedence : a ~ over the drawings. , fee ce mee omit it nt ct

13) Inthe event of a dimensional conflict, drawings take precedence over written specifications. Large-scale drawings shall take precedence over small-scale drawings. Bring any conflicting instructions or information to the attention of the Architect immediately.

14) These drawings are to be taken as a whole. Items or materials called out and described at one location are typical for all similar areas unless noted otherwise.

End of document