APASOLAR.COM
TM
WHERE INNOVATION MEETS AUTOMATION
GEOBALLAST FOUNDATION NO MORE CONCRETE
RAPID SETUP
By utilizing locally sourced quarry rock, simply drop the weight in and you’re done. No more waiting on concrete trucks, renting concrete pumps, or washing out trucks onsite. No more labor hours for setting up temporary concrete molds. No more waiting 24 hours for concrete to cure. The flow and speed of your job is 100% in your control.
The galvanized steel wire box is delivered to the site over 70% pre-assembled. Simply unfold the box, install the spiral wires and connect the anchor tubes. The Geoballast foundation is then fully assembled and can be moved to the proper position in the row and filled with quarry rock. It’s easy to assemble, stage, and stringline.
The Geoballast Foundation was developed after years of installing ballasted solar projects. Concrete, whether pre-cast or pour in place, proved to be an expensive and time-consuming method. Our innovative engineering and R&D teams developed a revolutionary process for ballasted projects. The goal was to remove all concrete and take the idea of a standard gabion basket and engineer it to excel as a ballast solution. Our highly engineered Geoballast box has the fastest installation time available, and is one of the most cost effective products on the market.
In business since 2008, APA offers a versatile line of racking and foundation solutions for projects in even the most challenging environments. With projects nationwide, APA is a trusted racking partner.
20-345 COUNTY ROAD X \\ P.O. BOX 224 \\ RIDGEVILLE CORNERS, OH 43555
419.267.5280 // SALES@APASOLAR.COM
WHY USE A GEOBALLAST FOUNDATION? TELESCOPING POST Both posts have adjustable positions to match site requirements.
APA Drawings can be PE stamped for all 50 States and territories Tilt Angles: 5°-35° Tilt Options Wind Loading: Up to 130mph Snow Loading: Up to 100psf Mounting Orientation: 2-High in Portrait Weight Requirement: 2,250 lbs per basket Foundation Coating: Galvanized with PVC coating for added protection
PRE-ASSEMBLED BASKET The ballast is shipped 70% assembled, which allows for lower labor cost and quick deployment.
SIMPLE SETUP PROCESS Place folded ballast basket on the ground Unfold basket and insert lower tube Install spiral retainers and u-bolt connections Place in desired location and fill with quarry rock
STANDARD QUARRY ROCK Rock can be sourced from local quarries to reduce shipping costs.
TM
419.267.5280 // SALES@APASOLAR.COM
Datasheet
250/275kW, 1500Vdc String Inverters for North America
CPS SCH275KTL-DO/US-800 The 250/275kW high power CPS three phase string inverters are designed for ground mount applications. The units are high performance, advanced and reliable inverters designed specifically for the North American environment and grid. High efficiencies, wide operating voltages, broad temperature ranges and NEMA Type 4X enclosure enable this inverter platform to operate at high performance across many applications. The SCH275KTL inverters include a selectable Active Power of either 250kW or 275kW (factory default) with 12 MPPTs and are available with either 36 fused PV string inputs or 24 unfused PV string inputs. The CPS FlexOM solution enables communication, controls and remote product upgrades.
Key Features ◼
NFPA 70, NEC 2017 compliant
◼
Touch safe DC Fuse holders adds convenience and safety
◼
Protection Functions for enhanced reliability and safety
◼ ◼ ◼
CPS FlexOM Gateway enables remote FW upgrades Integrated DC disconnect switch Selectable Max AC Active Power of 250kW or 275kW
CHINT POWER SYSTEMS AMERICA 2021/12-MKT NA
◼
12 MPPTs with 36 fused inputs or 24 unfused inputs
◼
Full power capacity up to 42°C
◼
Copper and Aluminum compatible AC connections
◼
Standard 5 year warranty with extensions to 20 years
◼
NEMA Type 4X outdoor rated, tough tested enclosure
◼
Supported comm protocols (Modbus RTU, TCP/IP, PLC, CAN)
Chint Power Systems America 6800 Koll Center Parkway, Suite 235 Pleasanton, CA 94566 Tel: 855-584-7168 Mail: AmericaSales@chintpower.com Web: www.chintpowersystems.com
Technical Data Model Name DC Input
CPS SCH275KTL-DO/US-800-36
CPS SCH275KTL-DO/US-800-24 1500V
Max. DC Input Voltage Operating DC Input Voltage Range
500-1450Vdc
Start-up DC Input Voltage / Power
550Vdc / 500W
MPPT Voltage Range @ PF>0.99 Number of MPP Trackers
900-1300Vdc
1
Max. PV Input Current Max. PV Short-Circuit Current Number of DC Inputs
12
12
26A per MPPT
30A per MPPT
600A, 50A per MPPT
600A, 50A per MPPT
36 Fused Inputs, 3 per MPPT Type II
DC Surge Protection AC Output
250kW / 275kW
Max AC Output Power (Selectable) @ PF>0.99
275kVA
Max. AC Apparent Power
800Vac
Rated Output Voltage Output Voltage Range Grid Connection Type
24 Non-Fused Inputs Load-rated DC switches
DC Disconnection Type
704-880Vac
2
3-Phase / PE 198.5A
Max. AC Output Current @800Vac
60Hz
Rated Output Frequency Output Frequency Range Power Factor
2
57 - 63Hz >0.99 (±0.8 adjustable)
Current THD @ Rated Load
<3%
Max. Fault Current Contribution (1 Cycle RMS)
215.2A
Max. OCPD Rating
300A
AC Surge Protection System and Performance
Type II
Max. Efficiency
99.0%
CEC Efficiency
98.5%
Stand-by / Night Consumption Environment
5W NEMA Type 4X
Enclosure Protection Degree
Variable speed cooling fans
Cooling Method Operating Temperature Range Operating Humidity
-22°F to +140°F / -30°C to +60°C (derating from +107°F / +42°C)
3
0 to 100% 8202ft / 2500m (no derating)
Operating Altitude
<80dBA @ 1m and 25°C
Audible Noise Display and Communication
LED indicators, WiFi + APP
User Interface and Display Inverter Monitoring
Modbus RS485 / Ethernet TCP/IP / PLC / CAN
Site Level Monitoring
CPS FlexOM (1 per 32 inverters) SunSpec / CPS
Modbus Data Mapping
Standard / (with FlexOM Gateway)
Remote Diagnostics / FW Upgrade Functions Mechanical
27.2 x 41.3 x 15.7in (690 x 1050 x 400mm)
Dimensions (HxWxD)
Approx. 262lbs / 119kg
Weight
Vertical installation
Mounting / Installation Angle AC Termination
Stud Type Terminal (Wire range: 3/0AWG – 600kcmil AL/CU, Lugs not supplied)
DC Termination
36 Fused Input: Screw Clamp Fuse Holder (Wire range: #14 - #6 AWG CU) 24 Non-Fused Input: Screw Clamp Terminal (Wire range: #14 - #8 and #6 - #4 AWG CU)
Fused String Inputs (3 per MPPT) Safety Certifications and Standards
4
20A fuses provided (Fuse values up to 30A acceptable) UL1741-SA Ed. 2, CSA-22.2 NO.107.1-16, IEEE1547-2018, FCC PART15
Selectable Grid Standard
IEEE 1547a-2014, CA Rule 21, ISO-NE
Smart-Grid Features Protection Functions
Volt-RideThru, Freq-RideThru, Ramp-Rate, Specified-PF, Volt-Var, Freq-Watt, Volt-Watt
Reactive Power at Night
Yes
IV Curve Tracing
Yes
Insulation Resistance Monitoring
Yes
Onboard Fault Oscillography
Yes
PV String Current Monitoring
Yes
Residual Current Monitoring
Yes
Input Reverse Polarity Protection
Yes
Output Overcurrent Protection
Yes
Output Short-Circuit Protection
Yes
Output Overvoltage Protection Warranty
Yes
Standard Extended Terms 1) See user manual for further information regarding MPPT Voltage Range when operating at non-unity PF 2) The "Output Voltage Range" and "Output Frequency Range" may differ according to the specific grid standard. 3) See user manual for further requirements regarding non-operating conditions. 4) Fused string inputs only applicable to the SCH275KTL 36 input model.
5 Years 10, 15 and 20 years
MADE IN VIETNAM, manufacture by VIETNAM SUNERGY JOINT STOCK COMPANY
30 25 YEAR YEAR QUALITY ASSURANCE
POWER OUTPUT GUARANTEE
VSUN610-132BMH-DG VSUN610-120BMH-DG
VSUN605-120BMH-DG
VSUN600-120BMH-DG
VSUN595-120BMH-DG
610W
21.55%
Highest power output
Module d
2.0%
0.45%
First-year degradation warranty
Annual degradation over 30 years
ciency
ABOUT VSUN KEY FEATURES
Invested by Fuji Solar, VSUN SOLAR is a solar solution provider with headquartered in Tokyo, Japan that offers reliability, high e
PERC
MBB technology with Circular Ribbon
ciency solar products and technology globally. VSUN
is rated as BNEF Tier 1 PV module manufacturer, PVEL Lab "Best performer" and EcoVadis "Bronze Award".
Higher output power Half-cell Technology
PRODUCT CERTIFICATION
Positive tolerance offer Bifacial cells, converting more sunlight into electricity
WARRANTY
Better shading tolerance 100%
98%
Load certificates: wind to 2400Pa and snow to 5400Pa 90% 84.95%
Lower LCOE 80% Number of
5 years
10 years
PERC Bifacial
15 years
20 years
25 years
30 years
General Bifacial
2023 . 5 . 13
MADE IN VIETNAM, manufacture by VIETNAM SUNERGY JOINT STOCK COMPANY
Electrical Characteristics at Standard Test Conditions(STC) VSUN610-120BMH-DG
Module Type
VSUN605-120BMH-DG
VSUN600-120BMH-DG
VSUN595-120BMH-DG
Pmax (W)
610
605
600
595
Voc (V)
41.82
41.65
41.48
41.3
Isc (A)
18.69
18.62
18.57
18.51
Vmpp (V)
34.73
34.56
34.39
34.21
Impp (A)
17.57
17.51
17.45
17.4
Module Efficiency
21.55%
21.38%
21.20%
21.02%
Standard Test Conditions (STC): irradiance 1,000 W/m²; AM 1,5; module temperature 25°C. Pmax Sorting : 0~5W. Measuring Tolerance: ±3%. Remark: Electrical data do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types.
Electrical Characteristics with different rear side power gain(reference to 605 front) Pmax (W)
Voc (V)
Isc (A)
Vmpp (V)
Impp (A)
Pmax gain
635
41.65
19.55
34.56
18.39
5%
666
41.65
20.48
34.56
19.26
10%
724
41.73
22.34
34.48
21.01
20%
755
41.73
23.28
34.48
21.89
25%
Material Characteristics
System Design
Dimensions
2172×1303×35mm (L×W×H)
Maximum System Voltage [V]
1500
36.4kg
Series Fuse Rating [A]
30
Silver anodized aluminum profile
Bifaciality
70%±10%
AR-coating Semi-toughened glass, 2.0mm
Fire Rating
Class C for IEC and TYPE 29 for US
Cell Encapsulation
EVA (Ethylene-Vinyl-Acetate) or POE
PV module classification
Back Glass
Glazed & Semi-toughened glass, 2.0mm
Temperature Range
Weight Frame Front Glass
12×10 pieces monocrystalline solar cells series
Cells
strings IP68, 3 diodes
Junction Box
Class II -40 °C to + 85 °C
Maximum Surface Load
5,400 Pa
Application class
Class A
500 mm (cable length can be customized), 1×4 mm2 or 12AWG, Connector: PV-ZH202B(Manufacturer
Cable
Maximum diameter of 25 mm with
Withstanding Hail
by Zhejiang Zhonghuan Sunter PV Technology Co., Ltd.)
Packaging
impact speed of 23 m/s
Temperature Characteristics
Dimensions(L×W×H)
1325×1125×2510mm
NOCT
Container 20'
/
Voltage Temperature Coefficient
-0.25%/°C
Container 40'
/
Current Temperature Coefficient
+0.04%/°C
Container 40'HC
540
Power Temperature Coefficient
-0.34%/°C
Dimensions
45°C(±2°C)
IV-Curves
Note:mm
B A-A Frame
B
11
A
AM1.5,1000W/M
2
10℃, Pmpp=642W 25℃, Pmpp=611W 40℃, Pmpp=580W 55℃, Pmpp=548W 70℃, Pmpp=516W
16
12
600
35
500
8
D
B-B Frame 11
400 300 200
4
100 0
0
10
20
30
40
Voltage/V
0
0
10
20
30
40
Voltage/V 13
C-Mounting Hole 8 place 9
C
2
1000W/M
500
1264±2
BACK VIEW
BACK VIEW
400
400W/M2
300
200W/M2
200
4 100
0
1303±2
600
2
600W/M
12
8
D-Mounting Hole 4 place 7
25℃
2
800W/M
16
0
10
20
30
40
0
Voltage/V Excellent performance under weak light condition.
2023 . 5 .13