MAIN ID WALL SIGNS SIGN #
LOCATION
1 EAST ELEVATION
SIGN TYPE
FCO LETTERS ON BACKER PANEL
DESIGN SIGN STATUS - FREESTANDING SIGNS
2 PHILLIPS RD
D/F MONUMENT SIGN - ILLUMINATED
DESIGN SIGN STATUS - SECONDARY WALL PANEL
1 3
3 EAST ELEVATION
FCO LETTERS - RENTAL OFFICE ON BACKER PANEL
2
1/128”=1’-0”
It is the intent and purpose of this color rendering to provide a basic color representation of your sign finish and color. However, digital media and printed colors will vary from actual paint finish and color. Existing painted surfaces will have a perceptible difference in shade and sheen from your sign finish. Providing a sample of the paint you wish to match or a Matthews paint color formula will minimize the differences.
16265 Star Rd., Nampa, ID 83687 - toll free: 800.592.8058 - tele: 208.345.4020
imagenational.com
U.S. & P.R. - All signs conform to UL-48/2161 (labeled accordingly) & must comply with UL-41.1 install procedures. Canada - all signs must be CAS compliant. This sign(s) is intended to be installed in accordance with requirements of article 600 of the National Electrical Code and/or applicable local codes. This includes proper grounding and bonding of the sign.
Site #: 23947 665 PHILLIPS RD WEBSTER, NY 14580
PBS-23947-WEBSTER NY-040126-R2
1
Sb
XX
HS
XX
04/01/26 Page
2 of 12
© 2026 Image National, Inc. This design is an original work of authorship by Image National, Inc. (image) which owns the copyright protection by the copyright law of the United States (title 17, U.S. Code). All rights are reserved by image and, until the use of this design is authorized by image in writing, image owns the exclusive rights to: a) reproduce this design in copies, in graphic form or as a sign; b) prepare derivative works based upon the design; c) distribute copies of the design by sale or other transfer of ownership; and d) display the design publicly.
Sign
1
FCO LOGO ON BACKER PANEL APPROACH VIEW
3/8” = 1’-0”
GENERAL / INSTALLER NOTES: • FCO letters on backer panel
9'-6 1/8"
CITY CODE & ALLOWANCES:
7'-11"
18”
4'-11 5/8"
18”
• 10% of the SF of the façade of the building
72.0 PROPOSED SQ. FT.:47.3
PART #PBSCB18SPSWH Mounting holes to be drilled on site
EXISTING CONDITIONS
• Verify wall size and space between down spout and edge of siding ±80’-0"
• Verify if architectural feature can be removed
±7’-2”
±9'-0”
12”
±13’-0”
1/16” = 1’-0” It is the intent and purpose of this color rendering to provide a basic color representation of your sign finish and color. However, digital media and printed colors will vary from actual paint finish and color. Existing painted surfaces will have a perceptible difference in shade and sheen from your sign finish. Providing a sample of the paint you wish to match or a Matthews paint color formula will minimize the differences.
16265 Star Rd., Nampa, ID 83687 - toll free: 800.592.8058 - tele: 208.345.4020
imagenational.com
U.S. & P.R. - All signs conform to UL-48/2161 (labeled accordingly) & must comply with UL-41.1 install procedures. Canada - all signs must be CAS compliant. This sign(s) is intended to be installed in accordance with requirements of article 600 of the National Electrical Code and/or applicable local codes. This includes proper grounding and bonding of the sign.
Site #: 23947 665 PHILLIPS RD WEBSTER, NY 14580
PBS-23947-WEBSTER NY-040126-R2
1
Sb
XX
HS
XX
04/01/26 Page
3 of 12
© 2026 Image National, Inc. This design is an original work of authorship by Image National, Inc. (image) which owns the copyright protection by the copyright law of the United States (title 17, U.S. Code). All rights are reserved by image and, until the use of this design is authorized by image in writing, image owns the exclusive rights to: a) reproduce this design in copies, in graphic form or as a sign; b) prepare derivative works based upon the design; c) distribute copies of the design by sale or other transfer of ownership; and d) display the design publicly.
Sign
2
D/F MONUMENT SIGN GENERAL / INSTALLER NOTES:
1/4” = 1’-0”
• Re use existing electrical
CITY CODE & ALLOWANCES:
7'-7 7/8"
• SF is determined by multiplying the developments highway foot frontage by the perpendicular distance in feet from the ROW line to the proposed sign location by 1
4’-0"
• 25’-0” Setback from ROW
3" 6”
3" 3" 1'-3”
5'-9"
1’-5”
665
APPROACH VIEW
±36.0 ALLOWED SQ. FT.: N/A PROPOSED SQ. FT.:30.6
±7’-0” ALLOWED OAH: 6’-0” PROPOSED OAH: 5’-9”
PART #PBSMN4X8SPS CUSTOM: “PUBLIC STORAGE” COPY TO ILLUMINATE ONLY. ORANGE BACKGROUND IS OPAQUE
EXISTING CONDITIONS
PROPOSED CONDITIONS
LOCATION DETAIL
8’-0”
55'-0”
±7'-0”
±4’-2”
±9’-4”
25’-0”
665 665 25'-0”
1/4” = 1’-0”
SIMULATED NIGHT VIEW
1/32” = 1’-0”
It is the intent and purpose of this color rendering to provide a basic color representation of your sign finish and color. However, digital media and printed colors will vary from actual paint finish and color. Existing painted surfaces will have a perceptible difference in shade and sheen from your sign finish. Providing a sample of the paint you wish to match or a Matthews paint color formula will minimize the differences.
16265 Star Rd., Nampa, ID 83687 - toll free: 800.592.8058 - tele: 208.345.4020
imagenational.com
U.S. & P.R. - All signs conform to UL-48/2161 (labeled accordingly) & must comply with UL-41.1 install procedures. Canada - all signs must be CAS compliant. This sign(s) is intended to be installed in accordance with requirements of article 600 of the National Electrical Code and/or applicable local codes. This includes proper grounding and bonding of the sign.
Site #: 23947 665 PHILLIPS RD WEBSTER, NY 14580
PBS-23947-WEBSTER NY-040126-R2
1
Sb
XX
HS
XX
04/01/26 Page
4 of 12
© 2026 Image National, Inc. This design is an original work of authorship by Image National, Inc. (image) which owns the copyright protection by the copyright law of the United States (title 17, U.S. Code). All rights are reserved by image and, until the use of this design is authorized by image in writing, image owns the exclusive rights to: a) reproduce this design in copies, in graphic form or as a sign; b) prepare derivative works based upon the design; c) distribute copies of the design by sale or other transfer of ownership; and d) display the design publicly.
Sign
3
FCO LETTERS ON BACKER - WALL MOUNTED APPROACH VIEW
3/4” = 1’-0”
GENERAL / INSTALLER NOTES: • Install new FCO on backer panel
CITY CODE & ALLOWANCES: • 10% of the SF of the façade of the building
6'-0" 4'-7 3/4”
EQ.
7”
12”
EQ.
PROPOSED SQ. FT.:6’-0”
PART # PBSCB07LROWH
EXISTING CONDITIONS
PROPOSED CONDITIONS
50'-0"
6”
±30'-0”
3/16” = 1’-0” It is the intent and purpose of this color rendering to provide a basic color representation of your sign finish and color. However, digital media and printed colors will vary from actual paint finish and color. Existing painted surfaces will have a perceptible difference in shade and sheen from your sign finish. Providing a sample of the paint you wish to match or a Matthews paint color formula will minimize the differences.
16265 Star Rd., Nampa, ID 83687 - toll free: 800.592.8058 - tele: 208.345.4020
imagenational.com
U.S. & P.R. - All signs conform to UL-48/2161 (labeled accordingly) & must comply with UL-41.1 install procedures. Canada - all signs must be CAS compliant. This sign(s) is intended to be installed in accordance with requirements of article 600 of the National Electrical Code and/or applicable local codes. This includes proper grounding and bonding of the sign.
Site #: 23947 665 PHILLIPS RD WEBSTER, NY 14580
PBS-23947-WEBSTER NY-040126-R2
1
Sb
XX
HS
XX
04/01/26 Page
5 of 12
© 2026 Image National, Inc. This design is an original work of authorship by Image National, Inc. (image) which owns the copyright protection by the copyright law of the United States (title 17, U.S. Code). All rights are reserved by image and, until the use of this design is authorized by image in writing, image owns the exclusive rights to: a) reproduce this design in copies, in graphic form or as a sign; b) prepare derivative works based upon the design; c) distribute copies of the design by sale or other transfer of ownership; and d) display the design publicly.
INSTALLER NOTES WALL
MOUNTING HARDWARE PAINTED TO MATCH BACKGROUND OF SIGN.
9'-6 1/8"
1/2"
FABRICATION SPECIFICATIONS
2
4'-11 5/8"
18”
1 PANEL 2 FCO LETTERS P1
1
18”
Align w/Bottom
V1
3 of ‘e’ to CL Edge Center of ®
3 TRADEMARK
N
MATERIAL COLOR MOUNTING MATERIAL MOUNTING MATERIAL COLOR
1/8” ALUMINUM PER COLOR KEY 1/4” x 6” STUDS 1/2” WHITE ACRYLIC SCREWS VINYL PER COLOR KEY
NOTES MOUNTING HARDWARE PAINTED TO MATCH BACKGROUND OF SIGN.
N.T.S. APPROVED FASTENER SCHEDULE
PART #PBSCB18SPSWH
1
FCO LOGO ON BACKER PANEL
REGISTRATION MARK PLACEMENT
3/8” = 1’-0”
N.T.S.
COLOR KEY P1 PAINT V1 VINYL
3/8" - 1/2" LAG SCREW
FOR USE WITH WOOD OR EIFS WALL SYSTEMS. 1 1/2" MIN PENETRATION (EXCLUDING TIP)
1/4" - 3/8" THREADED ROD
FOR USE WITH WOOD, CONCRETE BLOCK OR EIFS WALL SYSTEMS
3/8" RED HEAD L.D.T. (LARGE DIAMETER TAPCON)
FOR USE WITH CONRETE BLOCK, BRICK OR CONCRETE. EMBED A MIN. OF 2 1/2".
3/8" DIA. HILTI HIT ROD WITH HY150 MAX ADHESIVE
FOR USE WITH CONRETE. EMBED A MIN. OF 2"
3/8" DIA. HILTI HIT ROD WITH HY20 ADHESIVE
FOR USE WITH MASONRY AND BRICK. EMBED A MIN. OF 3 3/8"
3/8" DIA. HILTI HIT ROD WITH HY20 ADHESIVE
FOR USE WITH CONCRETE BLOCK. EMBED A MIN. OF 2"
3/8" DIA. HILTI HCL SLEEVE ANCHOR
FOR USE WITH CONCRETE, MASONRY AND BRICK. EMBED A MIN. OF 3 3/8".
3/8" DIA. LAG WITH 3/8" SHIELD & WASHER
FOR USE WITH CONCRETE, MASONRY AND BRICK - EMBED A MIN. OF 2"
#10 (3") HEX SCREW W/ FENDER WASHER INTO PLASTIC WALL ANCHOR
USE WITH CONCRETE, MASONRY & BRICK. FOR USE WITH SMALL/LIGHTWEIGHT LETTERS & CABINETS
PPG PS 101 ORANGE 3M WHITE
THE COLORS DEPICTED ON THIS RENDERING REPRESENT COLOR INTENT ONLY AND MAY NOT MATCH ACTUAL COLORS ON FINISHED PRODUCT. PLEASE REFER TO COLOR CALL-OUTS AND SPECIFIED VENDOR SAMPLES FOR APPROVED COLOR SPECIFICATIONS.
SHIPPING LIST 3/8” MOUNTING HOLES 3/16” HOLES FOR #10 x 24 FREE FIT SCREWS
N
P1
7'-11"
MATERIAL
QTY.
TOUCH UP PAINT
1 EA
1/2” FLEX CONNECTORS POWER SUPPLY T-CAN/SWITCH/SAFETY PLATE 1/4” X 12” ALL THREAD MFG. PLASTIC PASS THRU
3/8” = 1’-0”
MANUFACTURING REVISIONS A B C
ECO #
DESCRIPTION - INITIALS
ECO # ECO # ECO #
DESCRIPTION - INITIALS DESCRIPTION - INITIALS DESCRIPTION - INITIALS
It is the intent and purpose of this color rendering to provide a basic color representation of your sign finish and color. However, digital media and printed colors will vary from actual paint finish and color. Existing painted surfaces will have a perceptible difference in shade and sheen from your sign finish. Providing a sample of the paint you wish to match or a Matthews paint color formula will minimize the differences.
16265 Star Rd., Nampa, ID 83687 - toll free: 800.592.8058 - tele: 208.345.4020
imagenational.com
U.S. & P.R. - All signs conform to UL-48/2161 (labeled accordingly) & must comply with UL-41.1 install procedures. Canada - all signs must be CAS compliant. This sign(s) is intended to be installed in accordance with requirements of article 600 of the National Electrical Code and/or applicable local codes. This includes proper grounding and bonding of the sign.
Site #: 23947 665 PHILLIPS RD WEBSTER, NY 14580
PBS-23947-WEBSTER NY-040126-R2
1
Sb
XX
HS
XX
04/01/26 Page
9 of 12
© 2026 Image National, Inc. This design is an original work of authorship by Image National, Inc. (image) which owns the copyright protection by the copyright law of the United States (title 17, U.S. Code). All rights are reserved by image and, until the use of this design is authorized by image in writing, image owns the exclusive rights to: a) reproduce this design in copies, in graphic form or as a sign; b) prepare derivative works based upon the design; c) distribute copies of the design by sale or other transfer of ownership; and d) display the design publicly.
FABRICATION SPECIFICATIONS
1 CABINET 7'-7 7/8"
N
V1 3" 6”
665
4’-6"
3" 3" 1'-3”
5'-9"
4’-0"
1’-5”
P1
1
P3 P2
3 2 4
3 FCO NUMBERS
N
4 PAD 5 FOOTER 6 UPRIGHT
5
6”
6
Ø2’-0" PART #PBSMN4X8SPS
Ø2’-0"
2 BASE/REVEAL
N
V1 VINYL P1 PAINT P2 PAINT P3 PAINT
7’-7 7/8”
15 7/8”
TYPE
0.52 YARDS CONCRETE VOLUME
TYPE
4ӯ SCH. 40 STEEL PIPE
SIGNCOMP BODY
PIPE-TO-ANGLE 4 LOCATIONS @ 90° AROUND PIPE
3/16”
1”
SIGNCOMP SADDLE MOUNT SIGN DETAIL NOT TO SCALE
COLOR KEY
1/4” = 1’-0”
15 3/8”
SIGN COMP BLEED FRAME D/F PER COLOR KEY SATIN SMOOTH WHITE FLEXIBLE FACE PER COLOR KEY WHITE LED STEEL ANGLE NEST/24GA STEEL D/F PER COLOR KEY MEDIUM TEXTURE 1/2” ACRYLIC PER COLOR KEY STUD MOUNT TO BASE 3000 PSI CONCRETE - SEE NOTES
NOTES • (1) 20 AMP CIRCUIT REQUIRED TO SIGN BY OTHERS • DISCONNECT SWITCH ON NON-STREET SIDE • 3” TALL CONCRETE PAD BY IMAGE NATIONAL INSTALLER TO EXTEND 3” PAST BASE OF SIGN ON ALL SIDES
D/F MONUMENT SIGN
2
CONSTRUCTION TYPE PAINT COLOR FINISH FACE MATERIAL FACE COLOR ILLUMINATION CONSTRUCTION TYPE PAINT COLOR FINISH MATERIAL PAINT COLOR MOUNTING TYPE
STEEL PIPE/ SQ. TUBE
15 3/8”
3M ENVISION 3730-3109 PS ORANGE W/ 3660M UV FILM LAMINATED TO 3M WHITE BLOCKOUT VINYL PPG PS 101 ORANGE PPG 1024-1 OFF WHITE BLACK
THE COLORS DEPICTED ON THIS RENDERING REPRESENT COLOR INTENT ONLY AND MAY NOT MATCH ACTUAL COLORS ON FINISHED PRODUCT. PLEASE REFER TO COLOR CALL-OUTS AND SPECIFIED VENDOR SAMPLES FOR APPROVED COLOR SPECIFICATIONS.
5 5/8” 7 3/8”
2’-0”
4’-0”
SHIPPING LIST
30 3/8”
31 1/8”
30 3/8”
LED & SUPPORT LAYOUT
MATERIAL
QTY.
TOUCH UP PAINT
6 LF
POWER SUPPLY
1 EA
T-CAN/SWITCH/SAFETY PLATE
1 EA
1/4” X 12” ALL THREAD
39 EA
MFG. PLASTIC PASS THRU
13 EA
3/8” = 1’-0”
ELECTRICAL REQUIREMENTS VOLTS
120
AMP
2.2
CIRCUIT
1
‘CUSTOM’ DESCRIPTION • ORANGE BACKGROUND IS OPAQUE BY CODE
MANUFACTURING REVISIONS A B C
ECO #
DESCRIPTION - INITIALS
ECO # ECO # ECO #
DESCRIPTION - INITIALS DESCRIPTION - INITIALS DESCRIPTION - INITIALS
It is the intent and purpose of this color rendering to provide a basic color representation of your sign finish and color. However, digital media and printed colors will vary from actual paint finish and color. Existing painted surfaces will have a perceptible difference in shade and sheen from your sign finish. Providing a sample of the paint you wish to match or a Matthews paint color formula will minimize the differences.
16265 Star Rd., Nampa, ID 83687 - toll free: 800.592.8058 - tele: 208.345.4020
imagenational.com
U.S. & P.R. - All signs conform to UL-48/2161 (labeled accordingly) & must comply with UL-41.1 install procedures. Canada - all signs must be CAS compliant. This sign(s) is intended to be installed in accordance with requirements of article 600 of the National Electrical Code and/or applicable local codes. This includes proper grounding and bonding of the sign.
Site #: 23947 665 PHILLIPS RD WEBSTER, NY 14580
PBS-23947-WEBSTER NY-040126-R2
1
Sb
XX
HS
XX
04/01/26 Page
10 of 12
© 2026 Image National, Inc. This design is an original work of authorship by Image National, Inc. (image) which owns the copyright protection by the copyright law of the United States (title 17, U.S. Code). All rights are reserved by image and, until the use of this design is authorized by image in writing, image owns the exclusive rights to: a) reproduce this design in copies, in graphic form or as a sign; b) prepare derivative works based upon the design; c) distribute copies of the design by sale or other transfer of ownership; and d) display the design publicly.
Sign
3
FCO LETTERS ON BACKER - WALL MOUNTED
INSTALLER NOTES WALL
MOUNTING HARDWARE PAINTED TO MATCH BACKGROUND OF SIGN.
3/4” = 1’-0”
1/2"
P1
N
FABRICATION SPECIFICATIONS
1 PANEL 2 FCO LETTERS
N
MATERIAL COLOR MOUNTING MATERIAL COLOR MOUNTING
1/8” ALUMINUM PER COLOR KEY #10-24 x 6” STUDS 1/2” WHITE ACRYLIC PER COLOR KEY SCREWS
NOTES MOUNTING HARDWARE PAINTED TO MATCH BACKGROUND OF SIGN.
N.T.S. APPROVED FASTENER SCHEDULE
6'-0" EQ.
4'-7 3/4”
EQ.
3/8" - 1/2" LAG SCREW
FOR USE WITH WOOD OR EIFS WALL SYSTEMS. 1 1/2" MIN PENETRATION (EXCLUDING TIP)
1/4" - 3/8" THREADED ROD
FOR USE WITH WOOD, CONCRETE BLOCK OR EIFS WALL SYSTEMS
3/8" RED HEAD L.D.T. (LARGE DIAMETER TAPCON)
FOR USE WITH CONRETE BLOCK, BRICK OR CONCRETE. EMBED A MIN. OF 2 1/2".
3/8" DIA. HILTI HIT ROD WITH HY150 MAX ADHESIVE
FOR USE WITH CONRETE. EMBED A MIN. OF 2"
3/8" DIA. HILTI HIT ROD WITH HY20 ADHESIVE
FOR USE WITH MASONRY AND BRICK. EMBED A MIN. OF 3 3/8"
3/8" DIA. HILTI HIT ROD WITH HY20 ADHESIVE
FOR USE WITH CONCRETE BLOCK. EMBED A MIN. OF 2"
3/8" DIA. HILTI HCL SLEEVE ANCHOR
FOR USE WITH CONCRETE, MASONRY AND BRICK. EMBED A MIN. OF 3 3/8".
3/8" DIA. LAG WITH 3/8" SHIELD & WASHER
FOR USE WITH CONCRETE, MASONRY AND BRICK - EMBED A MIN. OF 2"
#10 (3") HEX SCREW W/ FENDER WASHER INTO PLASTIC WALL ANCHOR
USE WITH CONCRETE, MASONRY & BRICK. FOR USE WITH SMALL/LIGHTWEIGHT LETTERS & CABINETS
7”
12”
COLOR KEY P1
1
V1
2
V1 VINYL P1 PAINT
3M IJ5100R-10 REFLECTIVE WHITE PPG PS 101 ORANGE
THE COLORS DEPICTED ON THIS RENDERING REPRESENT COLOR INTENT ONLY AND MAY NOT MATCH ACTUAL COLORS ON FINISHED PRODUCT. PLEASE REFER TO COLOR CALL-OUTS AND SPECIFIED VENDOR SAMPLES FOR APPROVED COLOR SPECIFICATIONS.
PART # PBSCB07LROWH
SHIPPING LIST MATERIAL
QTY.
TOUCH UP PAINT
1 EA
1/2” FLEX CONNECTORS POWER SUPPLY T-CAN/SWITCH/SAFETY PLATE 1/4” X 12” ALL THREAD MFG. PLASTIC PASS THRU
MANUFACTURING REVISIONS A B C
ECO #
DESCRIPTION - INITIALS
ECO # ECO # ECO #
DESCRIPTION - INITIALS DESCRIPTION - INITIALS DESCRIPTION - INITIALS
It is the intent and purpose of this color rendering to provide a basic color representation of your sign finish and color. However, digital media and printed colors will vary from actual paint finish and color. Existing painted surfaces will have a perceptible difference in shade and sheen from your sign finish. Providing a sample of the paint you wish to match or a Matthews paint color formula will minimize the differences.
16265 Star Rd., Nampa, ID 83687 - toll free: 800.592.8058 - tele: 208.345.4020
imagenational.com
U.S. & P.R. - All signs conform to UL-48/2161 (labeled accordingly) & must comply with UL-41.1 install procedures. Canada - all signs must be CAS compliant. This sign(s) is intended to be installed in accordance with requirements of article 600 of the National Electrical Code and/or applicable local codes. This includes proper grounding and bonding of the sign.
Site #: 23947 665 PHILLIPS RD WEBSTER, NY 14580
PBS-23947-WEBSTER NY-040126-R2
1
Sb
XX
HS
XX
04/01/26 Page
11 of 12
© 2026 Image National, Inc. This design is an original work of authorship by Image National, Inc. (image) which owns the copyright protection by the copyright law of the United States (title 17, U.S. Code). All rights are reserved by image and, until the use of this design is authorized by image in writing, image owns the exclusive rights to: a) reproduce this design in copies, in graphic form or as a sign; b) prepare derivative works based upon the design; c) distribute copies of the design by sale or other transfer of ownership; and d) display the design publicly.